A c cannons (19 resultados)

Filtrar la búsqueda

  • Libros (19)

  • Nuevo (19)

a

Intervalo de precios personalizado (EUR)

a

  • Idioma: Inglés

    Editorial: IWA Publishing, London, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: Grand Eagle Retail, Bensenville, IL, Estados Unidos de AmericaGrand Eagle Retail

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 150,18

     Gastos de envío gratis 
    Se envía dentro de Estados Unidos de America

    Cantidad disponible: 1 disponibles

    Paperback. Condición: new. Paperback. Two methods for the detection of important human pathogens, Cryptosporidium parvum and Helicobacter pylori, were investigated: a fiber optic biosensor, and real time PCR. The mechanism for specific detection in both methods is recognition of specific DNA sequences in the target organisms. The biosensor that was used, the Analyte 2000, was originally developed for the detection of chemicals. It utilizes a fiber optic wave guide that propagates an evanescent light wave of very specific wavelength. The light excites fluorescent molecules bound to the waveguide, but not in the bulk solution, which theoretically enhances signal while reducing background interference. Attempts to develop this system for the detection of DNA were not successful due to poor detection of the target molecules. An assay analogous to a sandwich immunoassay was designed for use on the Analyte 2000. Specific oligonucleotide probes were designed to bind to the waveguides via biotin-streptavidin interaction, and were used to capture the target DNA. Pure target DNA representing unique genes in the organisms were synthesized by PCR.Detection of captured DNA was then attempted using an oligonucleotide detection probe designed to bind to the target. Two detection systems were employed: an indirect signal amplification system based on biotin-tyramide deposition, or direct detection of fluorescent signal from Cy-5 molecules. In all experiments performed there was very little difference between the signal generated with or without the target molecules. Many experiments were conducted to attempt to identify reasons for the poor signal. Signal was only of any significance when target amplicons were internally labeled with Cy-5 by PCR. Real time PCR as a method to detect the pathogens was also investigated. Though the PCR technique itself is very rapid, DNA extraction and purification requires preparation time. Filtration of up to one liter of well water, followed by concentration and "cleaning" Helicobacter pylori cells by immunomagnetic separation, was used to detect H. pylori seeded in a water source. Following cell lysis, the extracted DNA could be used directly in conventional PCR targeting the 16S rRNA gene to detect less than 265 cells per liter of water.DNA purification was not required for this level of detection. Initial studies to amplify lysed cells by real time PCR indicated that an incorrect product was made. When purified DNA was used for real time PCR, the correct product was produced from DNA representing as few as 100 cells. Two methods for the detection of important human pathogens, Cryptosporidium parvum and Helicobacter pylori, were investigated: a fiber optic biosensor, and real time PCR. The mechanism for specific detection in both methods is, recognition of specific DNA sequences in the target organisms. The Analyte 2000 was the biosensor that was used. Shipping may be from multiple locations in the US or from the UK, depending on stock availability.

  • Idioma: Inglés

    Editorial: IWA Publishing, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: PBShop.store US, Wood Dale, IL, Estados Unidos de AmericaPBShop.store US

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 150,36

     Gastos de envío gratis 
    Se envía dentro de Estados Unidos de America

    Cantidad disponible: 9 disponibles

    PAP. Condición: New. New Book. Shipped from UK. Established seller since 2000.

  • Idioma: Inglés

    Editorial: IWA Publishing, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: PBShop.store UK, Fairford, GLOS, Reino UnidoPBShop.store UK

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 147,45

    Envío por EUR 3,84 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 7 disponibles

    PAP. Condición: New. New Book. Shipped from UK. Established seller since 2000.

  • Idioma: Inglés

    Editorial: WERF, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: Brook Bookstore On Demand, Napoli, NA, ItaliaBrook Bookstore On Demand

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 152,60

    Envío por EUR 4,00 
    Se envía de Italia a Estados Unidos de America

    Cantidad disponible: 7 disponibles

    Condición: new.

  • Idioma: Inglés

    Editorial: IWA Publishing, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: Majestic Books, Hounslow, Reino UnidoMajestic Books

    Vendedor de 4 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 163,68

    Envío por EUR 7,58 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 3 disponibles

    Condición: New. pp. 72 6:B&W 8.25 x 11 in or 280 x 210 mm Perfect Bound on White w/Gloss Lam.

  • Idioma: Inglés

    Editorial: IWA Publishing, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: Books Puddle, New York, NY, Estados Unidos de AmericaBooks Puddle

    Vendedor de 4 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 174,03

    Envío por EUR 3,47 
    Se envía dentro de Estados Unidos de America

    Cantidad disponible: 3 disponibles

    Condición: New. pp. 72.

  • Idioma: Inglés

    Editorial: Iwa Pub, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: Speedyhen, Hertfordshire, Reino UnidoSpeedyhen

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 130,55

    Envío por EUR 47,81 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 7 disponibles

    Condición: NEW.

  • Idioma: Inglés

    Editorial: IWA Publishing, GB, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: Rarewaves USA, HEBRON, KY, Estados Unidos de AmericaRarewaves USA

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 182,90

     Gastos de envío gratis 
    Se envía dentro de Estados Unidos de America

    Cantidad disponible: 4 disponibles

    Paperback. Condición: New. Two methods for the detection of important human pathogens, Cryptosporidium parvum and Helicobacter pylori, were investigated: a fiber optic biosensor, and real time PCR. The mechanism for specific detection in both methods is recognition of specific DNA sequences in the target organisms.   The biosensor that was used, the Analyte 2000, was originally developed for the detection of chemicals. It utilizes a fiber optic wave guide that propagates an evanescent light wave of very specific wavelength. The light excites fluorescent molecules bound to the waveguide, but not in the bulk solution, which theoretically enhances signal while reducing background interference. Attempts to develop this system for the detection of DNA were not successful due to poor detection of the target molecules. An assay analogous to a sandwich immunoassay was designed for use on the Analyte 2000. Specific oligonucleotide probes were designed to bind to the waveguides via biotin-streptavidin interaction, and were used to capture the target DNA.  Pure target DNA representing unique genes in the organisms were synthesized by PCR. Detection of captured DNA was then attempted using an oligonucleotide detection probe designed to bind to the target.  Two detection systems were employed: an indirect signal amplification system based on biotin-tyramide deposition, or direct detection of fluorescent signal from Cy-5 molecules. In all experiments performed there was very little difference between the signal generated with or without the target molecules. Many experiments were conducted to attempt to identify reasons for the poor signal.  Signal was only of any significance when target amplicons were internally labeled with Cy-5 by PCR. Real time PCR as a method to detect the pathogens was also investigated. Though the PCR technique itself is very rapid, DNA extraction and purification requires preparation time. Filtration of up to one liter of well water, followed by concentration and "cleaning" Helicobacter pylori cells by immunomagnetic separation, was used to detect H. pylori seeded in a water source.  Following cell lysis, the extracted DNA could be used directly in conventional PCR targeting the 16S rRNA gene to detect less than 265 cells per liter of water. DNA purification was not required for this level of detection. Initial studies to amplify lysed cells by real time PCR indicated that an incorrect product was made. When purified DNA was used for real time PCR, the correct product was produced from DNA representing as few as 100 cells. This publication can be purchased and downloaded via Pay Per View on Water Intelligence Online - click on the Pay Per View icon below.

  • Idioma: Inglés

    Editorial: IWA Publishing, GB, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: Rarewaves.com USA, London, LONDO, Reino UnidoRarewaves.com USA

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 188,18

     Gastos de envío gratis 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 4 disponibles

    Paperback. Condición: New. Two methods for the detection of important human pathogens, Cryptosporidium parvum and Helicobacter pylori, were investigated: a fiber optic biosensor, and real time PCR. The mechanism for specific detection in both methods is recognition of specific DNA sequences in the target organisms.   The biosensor that was used, the Analyte 2000, was originally developed for the detection of chemicals. It utilizes a fiber optic wave guide that propagates an evanescent light wave of very specific wavelength. The light excites fluorescent molecules bound to the waveguide, but not in the bulk solution, which theoretically enhances signal while reducing background interference. Attempts to develop this system for the detection of DNA were not successful due to poor detection of the target molecules. An assay analogous to a sandwich immunoassay was designed for use on the Analyte 2000. Specific oligonucleotide probes were designed to bind to the waveguides via biotin-streptavidin interaction, and were used to capture the target DNA.  Pure target DNA representing unique genes in the organisms were synthesized by PCR. Detection of captured DNA was then attempted using an oligonucleotide detection probe designed to bind to the target.  Two detection systems were employed: an indirect signal amplification system based on biotin-tyramide deposition, or direct detection of fluorescent signal from Cy-5 molecules. In all experiments performed there was very little difference between the signal generated with or without the target molecules. Many experiments were conducted to attempt to identify reasons for the poor signal.  Signal was only of any significance when target amplicons were internally labeled with Cy-5 by PCR. Real time PCR as a method to detect the pathogens was also investigated. Though the PCR technique itself is very rapid, DNA extraction and purification requires preparation time. Filtration of up to one liter of well water, followed by concentration and "cleaning" Helicobacter pylori cells by immunomagnetic separation, was used to detect H. pylori seeded in a water source.  Following cell lysis, the extracted DNA could be used directly in conventional PCR targeting the 16S rRNA gene to detect less than 265 cells per liter of water. DNA purification was not required for this level of detection. Initial studies to amplify lysed cells by real time PCR indicated that an incorrect product was made. When purified DNA was used for real time PCR, the correct product was produced from DNA representing as few as 100 cells. This publication can be purchased and downloaded via Pay Per View on Water Intelligence Online - click on the Pay Per View icon below.

  • Idioma: Inglés

    Editorial: IWA Publishing, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: THE SAINT BOOKSTORE, Southport, Reino UnidoTHE SAINT BOOKSTORE

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 172,98

    Envío por EUR 15,04 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 9 disponibles

    Paperback / softback. Condición: New. New copy - Usually dispatched within 3 working days.

  • Idioma: Inglés

    Editorial: IWA Publishing, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: Kennys Bookshop and Art Galleries Ltd., Galway, GY, IrlandaKennys Bookshop and Art Galleries Ltd.

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 178,21

    Envío por EUR 9,50 
    Se envía de Irlanda a Estados Unidos de America

    Cantidad disponible: 7 disponibles

    Condición: New. 2004. paperback. . . . . .

  • Idioma: Inglés

    Editorial: IWA Publishing, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: Biblios, frankfurt am main, HESSE, AlemaniaBiblios

    Vendedor de 4 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 182,12

    Envío por EUR 9,95 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 3 disponibles

    Condición: New. pp. 72.

  • Idioma: Inglés

    Editorial: WERF, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: moluna, Greven, Alemaniamoluna

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 155,63

    Envío por EUR 48,99 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 5 disponibles

    Condición: New. KlappentextrnrnTwo methods for the detection of important human pathogens, Cryptosporidium parvum and Helicobacter pylori, were investigated: a fiber optic biosensor, and real time PCR. The mechanism for specific detection in both methods is rec.

  • Idioma: Inglés

    Editorial: IWA Publishing, GB, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: Rarewaves USA United, HEBRON, KY, Estados Unidos de AmericaRarewaves USA United

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 188,05

    Envío por EUR 43,53 
    Se envía dentro de Estados Unidos de America

    Cantidad disponible: 4 disponibles

    Paperback. Condición: New. Two methods for the detection of important human pathogens, Cryptosporidium parvum and Helicobacter pylori, were investigated: a fiber optic biosensor, and real time PCR. The mechanism for specific detection in both methods is recognition of specific DNA sequences in the target organisms.   The biosensor that was used, the Analyte 2000, was originally developed for the detection of chemicals. It utilizes a fiber optic wave guide that propagates an evanescent light wave of very specific wavelength. The light excites fluorescent molecules bound to the waveguide, but not in the bulk solution, which theoretically enhances signal while reducing background interference. Attempts to develop this system for the detection of DNA were not successful due to poor detection of the target molecules. An assay analogous to a sandwich immunoassay was designed for use on the Analyte 2000. Specific oligonucleotide probes were designed to bind to the waveguides via biotin-streptavidin interaction, and were used to capture the target DNA.  Pure target DNA representing unique genes in the organisms were synthesized by PCR. Detection of captured DNA was then attempted using an oligonucleotide detection probe designed to bind to the target.  Two detection systems were employed: an indirect signal amplification system based on biotin-tyramide deposition, or direct detection of fluorescent signal from Cy-5 molecules. In all experiments performed there was very little difference between the signal generated with or without the target molecules. Many experiments were conducted to attempt to identify reasons for the poor signal.  Signal was only of any significance when target amplicons were internally labeled with Cy-5 by PCR. Real time PCR as a method to detect the pathogens was also investigated. Though the PCR technique itself is very rapid, DNA extraction and purification requires preparation time. Filtration of up to one liter of well water, followed by concentration and "cleaning" Helicobacter pylori cells by immunomagnetic separation, was used to detect H. pylori seeded in a water source.  Following cell lysis, the extracted DNA could be used directly in conventional PCR targeting the 16S rRNA gene to detect less than 265 cells per liter of water. DNA purification was not required for this level of detection. Initial studies to amplify lysed cells by real time PCR indicated that an incorrect product was made. When purified DNA was used for real time PCR, the correct product was produced from DNA representing as few as 100 cells. This publication can be purchased and downloaded via Pay Per View on Water Intelligence Online - click on the Pay Per View icon below.

  • Idioma: Inglés

    Editorial: IWA Publishing, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: Kennys Bookstore, Olney, MD, Estados Unidos de AmericaKennys Bookstore

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 225,05

    Envío por EUR 9,14 
    Se envía dentro de Estados Unidos de America

    Cantidad disponible: 7 disponibles

    Condición: New. 2004. paperback. . . . . . Books ship from the US and Ireland.

  • Idioma: Inglés

    Editorial: Werf, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: preigu, Osnabrück, Alemaniapreigu

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 172,05

    Envío por EUR 70,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponibles

    Taschenbuch. Condición: Neu. Sensor Technology for Water Quality Monitoring | Fiber-Optic Biosensor | A. C. Cannons (u. a.) | Taschenbuch | Werf Report S | Kartoniert / Broschiert | Englisch | 2004 | Werf | EAN 9781843396772 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

  • Idioma: Inglés

    Editorial: IWA Publishing, GB, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: Rarewaves.com UK, London, Reino UnidoRarewaves.com UK

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 182,31

    Envío por EUR 75,80 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 4 disponibles

    Paperback. Condición: New. Two methods for the detection of important human pathogens, Cryptosporidium parvum and Helicobacter pylori, were investigated: a fiber optic biosensor, and real time PCR. The mechanism for specific detection in both methods is recognition of specific DNA sequences in the target organisms.   The biosensor that was used, the Analyte 2000, was originally developed for the detection of chemicals. It utilizes a fiber optic wave guide that propagates an evanescent light wave of very specific wavelength. The light excites fluorescent molecules bound to the waveguide, but not in the bulk solution, which theoretically enhances signal while reducing background interference. Attempts to develop this system for the detection of DNA were not successful due to poor detection of the target molecules. An assay analogous to a sandwich immunoassay was designed for use on the Analyte 2000. Specific oligonucleotide probes were designed to bind to the waveguides via biotin-streptavidin interaction, and were used to capture the target DNA.  Pure target DNA representing unique genes in the organisms were synthesized by PCR. Detection of captured DNA was then attempted using an oligonucleotide detection probe designed to bind to the target.  Two detection systems were employed: an indirect signal amplification system based on biotin-tyramide deposition, or direct detection of fluorescent signal from Cy-5 molecules. In all experiments performed there was very little difference between the signal generated with or without the target molecules. Many experiments were conducted to attempt to identify reasons for the poor signal.  Signal was only of any significance when target amplicons were internally labeled with Cy-5 by PCR. Real time PCR as a method to detect the pathogens was also investigated. Though the PCR technique itself is very rapid, DNA extraction and purification requires preparation time. Filtration of up to one liter of well water, followed by concentration and "cleaning" Helicobacter pylori cells by immunomagnetic separation, was used to detect H. pylori seeded in a water source.  Following cell lysis, the extracted DNA could be used directly in conventional PCR targeting the 16S rRNA gene to detect less than 265 cells per liter of water. DNA purification was not required for this level of detection. Initial studies to amplify lysed cells by real time PCR indicated that an incorrect product was made. When purified DNA was used for real time PCR, the correct product was produced from DNA representing as few as 100 cells. This publication can be purchased and downloaded via Pay Per View on Water Intelligence Online - click on the Pay Per View icon below.

  • Idioma: Inglés

    Editorial: IWA Publishing, London, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: AussieBookSeller, Truganina, VIC, AustraliaAussieBookSeller

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 245,49

    Envío por EUR 32,21 
    Se envía de Australia a Estados Unidos de America

    Cantidad disponible: 1 disponibles

    Paperback. Condición: new. Paperback. Two methods for the detection of important human pathogens, Cryptosporidium parvum and Helicobacter pylori, were investigated: a fiber optic biosensor, and real time PCR. The mechanism for specific detection in both methods is recognition of specific DNA sequences in the target organisms. The biosensor that was used, the Analyte 2000, was originally developed for the detection of chemicals. It utilizes a fiber optic wave guide that propagates an evanescent light wave of very specific wavelength. The light excites fluorescent molecules bound to the waveguide, but not in the bulk solution, which theoretically enhances signal while reducing background interference. Attempts to develop this system for the detection of DNA were not successful due to poor detection of the target molecules. An assay analogous to a sandwich immunoassay was designed for use on the Analyte 2000. Specific oligonucleotide probes were designed to bind to the waveguides via biotin-streptavidin interaction, and were used to capture the target DNA. Pure target DNA representing unique genes in the organisms were synthesized by PCR.Detection of captured DNA was then attempted using an oligonucleotide detection probe designed to bind to the target. Two detection systems were employed: an indirect signal amplification system based on biotin-tyramide deposition, or direct detection of fluorescent signal from Cy-5 molecules. In all experiments performed there was very little difference between the signal generated with or without the target molecules. Many experiments were conducted to attempt to identify reasons for the poor signal. Signal was only of any significance when target amplicons were internally labeled with Cy-5 by PCR. Real time PCR as a method to detect the pathogens was also investigated. Though the PCR technique itself is very rapid, DNA extraction and purification requires preparation time. Filtration of up to one liter of well water, followed by concentration and "cleaning" Helicobacter pylori cells by immunomagnetic separation, was used to detect H. pylori seeded in a water source. Following cell lysis, the extracted DNA could be used directly in conventional PCR targeting the 16S rRNA gene to detect less than 265 cells per liter of water.DNA purification was not required for this level of detection. Initial studies to amplify lysed cells by real time PCR indicated that an incorrect product was made. When purified DNA was used for real time PCR, the correct product was produced from DNA representing as few as 100 cells. Two methods for the detection of important human pathogens, Cryptosporidium parvum and Helicobacter pylori, were investigated: a fiber optic biosensor, and real time PCR. The mechanism for specific detection in both methods is, recognition of specific DNA sequences in the target organisms. The Analyte 2000 was the biosensor that was used. Shipping may be from our Sydney, NSW warehouse or from our UK or US warehouse, depending on stock availability.

  • Idioma: Inglés

    Editorial: IWA Publishing Sep 2004, 2004

    1843396777 / 9781843396772

    • Tapa blanda

    Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 268,70

    Envío por EUR 30,50 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 2 disponibles

    Taschenbuch. Condición: Neu. Neuware - Two methods for the detection of important human pathogens, Cryptosporidium parvum and Helicobacter pylori, were investigated: a fiber optic biosensor, and real time PCR. The mechanism for specific detection in both methods is recognition of specific DNA sequences in the target organisms. The biosensor that was used, the Analyte 2000, was originally developed for the detection of chemicals. It utilizes a fiber optic wave guide that propagates an evanescent light wave of very specific wavelength. The light excites fluorescent molecules bound to the waveguide, but not in the bulk solution, which theoretically enhances signal while reducing background interference. Attempts to develop this system for the detection of DNA were not successful due to poor detection of the target molecules. An assay analogous to a sandwich immunoassay was designed for use on the Analyte 2000. Specific oligonucleotide probes were designed to bind to the waveguides via biotin-streptavidin interaction, and were used to capture the target DNA. Pure target DNA representing unique genes in the organisms were synthesized by PCR. Detection of captured DNA was then attempted using an oligonucleotide detection probe designed to bind to the target. Two detection systems were employed: an indirect signal amplification system based on biotin-tyramide deposition, or direct detection of fluorescent signal from Cy-5 molecules. In all experiments performed there was very little difference between the signal generated with or without the target molecules. Many experiments were conducted to attempt to identify reasons for the poor signal. Signal was only of any significance when target amplicons were internally labeled with Cy-5 by PCR. Real time PCR as a method to detect the pathogens was also investigated. Though the PCR technique itself is very rapid, DNA extraction and purification requires preparation time. Filtration of up to one liter of well water, followed by concentration and 'cleaning' Helicobacter pylori cells by immunomagnetic separation, was used to detect H. pylori seeded in a water source. Following cell lysis, the extracted DNA could be used directly in conventional PCR targeting the 16S rRNA gene to detect less than 265 cells per liter of water. DNA purification was not required for this level of detection. Initial studies to amplify lysed cells by real time PCR indicated that an incorrect product was made. When purified DNA was used for real time PCR, the correct product was produced from DNA representing as few as 100 cells.