Isbn: 9783642459955 - modern methods of plant analysis / moderne methoden der pflanzenanalyse: 5 (10 resultados)

ISBN: 
Refinar con la Búsqueda avanzada

Filtrar la búsqueda

  • Libros (10)

  • Nuevo (10)

a

Intervalo de precios personalizado (EUR)

a

  • Condición: Nuevo

    EUR 128,11

    Envío por EUR 17,41 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    Condición: New. In English.

  • Idioma: Inglés

    Editorial: Springer, 2012

    3642459951 / 9783642459955

    • Tapa blanda

    Librería: Books Puddle, Woodside, NY, Estados Unidos de AmericaBooks Puddle

    Vendedor de 4 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 154,58

    Envío por EUR 3,51 
    Se envía dentro de Estados Unidos de America

    Cantidad disponible: 4 disponibles

    Condición: New. pp. 568 Index.

  • Idioma: Inglés

    Editorial: Springer, 2012

    3642459951 / 9783642459955

    • Tapa blanda

    Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 120,14

    Envío por EUR 35,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. Druck auf Anfrage Neuware - Printed after ordering - 123 phase and hence have no direct bearing on the retention time of solutes. However in gas-solid chromatography, a considerable quantity of the mobile phase may be adsorbed on the surface of the stationary adsorbent which diminishes the column's effective length and ability to retain solutes. In this respect helium has been found to be preferable to most other gases (GREENE and Roy, 1957) because it is adsorbed to the least extent. 3. Packed columns offer a considerable resistance to flow, which may create a pressure differential between inlet and outlet of sufficient magnitude to cause an unfavorable flow rate through a significant length of the column. A reduced inlet/outlet pressure ratio can be obtained by using light molecular weight gases toward which the column packing shows the greatest permeability. The flow rate of the mobile phase is normally adjusted by altering the column inlet pressure, for which purpose commercial pressure regulators of sufficient accuracy are available. Quantitative measurements of the flow rate can be made by a number of methods, including rotameters, orifice meters, soapfilm flow meters and displacement of water. The former two methods are the most con venient but the least accurate; moreover they create a back pressure and are temperature dependent whereas although the moving soap bubble is cumbersome to employ and unusable for continuous readings, it is preferred when the highest accuracy is required.…

  • Idioma: Inglés

    Editorial: Springer-Verlag, 2013

    3642459951 / 9783642459955

    • Tapa blanda

    Librería: Revaluation Books, Exeter, Reino UnidoRevaluation Books

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 161,24

    Envío por EUR 14,57 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 2 disponibles

    Paperback. Condición: Brand New. multilingual edition. 568 pages. French language. 9.61x6.69x1.28 inches. In Stock.

  • Idioma: Inglés

    Editorial: Springer, 2012

    3642459951 / 9783642459955

    • Tapa blanda
    • Impresión bajo demanda

    Librería: Brook Bookstore On Demand, Napoli, NA, ItaliaBrook Bookstore On Demand

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 86,24

    Envío por EUR 8,00 
    Se envía de Italia a Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    Condición: new. Questo è un articolo print on demand.

  • Idioma: Inglés

    Editorial: Springer Berlin Heidelberg Apr 2012, 2012

    3642459951 / 9783642459955

    • Tapa blanda
    • Impresión bajo demanda

    Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 106,99

    Envío por EUR 23,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 2 disponibles

    Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -123 phase and hence have no direct bearing on the retention time of solutes. However in gas-solid chromatography, a considerable quantity of the mobile phase may be adsorbed on the surface of the stationary adsorbent which diminishes the column's effective length and ability to retain solutes. In this respect helium has been found to be preferable to most other gases (GREENE and Roy, 1957) because it is adsorbed to the least extent. 3. Packed columns offer a considerable resistance to flow, which may create a pressure differential between inlet and outlet of sufficient magnitude to cause an unfavorable flow rate through a significant length of the column. A reduced inlet/outlet pressure ratio can be obtained by using light molecular weight gases toward which the column packing shows the greatest permeability. The flow rate of the mobile phase is normally adjusted by altering the column inlet pressure, for which purpose commercial pressure regulators of sufficient accuracy are available. Quantitative measurements of the flow rate can be made by a number of methods, including rotameters, orifice meters, soapfilm flow meters and displacement of water. The former two methods are the most con venient but the least accurate; moreover they create a back pressure and are temperature dependent whereas although the moving soap bubble is cumbersome to employ and unusable for continuous readings, it is preferred when the highest accuracy is required. 568 pp. Englisch, Französisch, Deutsch.…

  • Condición: Nuevo

    EUR 92,27

    Envío por EUR 48,99 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    Kartoniert / Broschiert. Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. 123 phase and hence have no direct bearing on the retention time of solutes. However in gas-solid chromatography, a considerable quantity of the mobile phase may be adsorbed on the surface of the stationary adsorbent which diminishes the column s effective .…

  • Idioma: Inglés

    Editorial: Springer, 2012

    3642459951 / 9783642459955

    • Tapa blanda
    • Impresión bajo demanda

    Librería: Majestic Books, Hounslow, Reino UnidoMajestic Books

    Vendedor de 4 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 157,80

    Envío por EUR 7,58 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 4 disponibles

    Condición: New. Print on Demand pp. 568 67:B&W 6.69 x 9.61 in or 244 x 170 mm (Pinched Crown) Perfect Bound on White w/Gloss Lam.

  • Idioma: Inglés

    Editorial: Springer, 2012

    3642459951 / 9783642459955

    • Tapa blanda
    • Impresión bajo demanda

    Librería: Biblios, frankfurt am main, HESSE, AlemaniaBiblios

    Vendedor de 4 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 156,86

    Envío por EUR 9,95 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 4 disponibles

    Condición: New. PRINT ON DEMAND pp. 568.

  • Idioma: Inglés

    Editorial: Springer, Springer Apr 2012, 2012

    3642459951 / 9783642459955

    • Tapa blanda
    • Impresión bajo demanda

    Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 106,99

    Envío por EUR 60,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -123 phase and hence have no direct bearing on the retention time of solutes. However in gas-solid chromatography, a considerable quantity of the mobile phase may be adsorbed on the surface of the stationary adsorbent which diminishes the column's effective length and ability to retain solutes. In this respect helium has been found to be preferable to most other gases (GREENE and Roy, 1957) because it is adsorbed to the least extent. 3. Packed columns offer a considerable resistance to flow, which may create a pressure differential between inlet and outlet of sufficient magnitude to cause an unfavorable flow rate through a significant length of the column. A reduced inlet/outlet pressure ratio can be obtained by using light molecular weight gases toward which the column packing shows the greatest permeability. The flow rate of the mobile phase is normally adjusted by altering the column inlet pressure, for which purpose commercial pressure regulators of sufficient accuracy are available. Quantitative measurements of the flow rate can be made by a number of methods, including rotameters, orifice meters, soapfilm flow meters and displacement of water. The former two methods are the most con venient but the least accurate; moreover they create a back pressure and are temperature dependent whereas although the moving soap bubble is cumbersome to employ and unusable for continuous readings, it is preferred when the highest accuracy is required.Springer-Verlag KG, Sachsenplatz 4-6, 1201 Wien 568 pp. Englisch.…