Filtrar la búsqueda

  • Libros (5)

  • Nuevo (5)

a

Intervalo de precios personalizado (EUR)

a

R m belokar (5 resultados)

  • Idioma: Inglés

    Editorial: GRIN Verlag, 2019

    3346068277 / 9783346068279

    • Tapa blanda

    Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 15,95

    Envío por EUR 35,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. Druck auf Anfrage Neuware - Printed after ordering - Technical Report from the year 2019 in the subject Engineering - Mechanical Engineering, grade: 10.00, , language: English, abstract: Ankle foot orthosis (AFO) are externally applied device that a reused to support as well as control the foot and ankle joint of patients having foot deformity. Foot drop is caused by a deficiency in the ankle joint in which results in the weakness of ankle and toe dorsiflexion. This research proposes a new approach to design and performance evaluation of AFO fabrication that utilizes modeling, simulation and analysis software (like Open Sim, Ansys Work bench & Solid work) and additive manufacturing technologies to customize the fit form to an individual. By implementing a carbon fibre strut at ankle joint the design will result in a stronger, more comfortable, more flexible AFO that can adaptively constrain ankle movement for various different activities.GAIT Analysis was performed on six patients having foot drop, from the emotion analysis system in the GAIT lab. The data from the GAIT lab was then imported into the Open Sim to create a biomechanics simulation to extract the joint angle and joint moments. These value of ankle angle and moment with & without AFO was compared with normal value. The results show a considerable effect of the use of the AFO by drop foot patients in terms of ankle angle and ankle moments. Furthermore, the muscular analysis in terms of activation and forces also suggest that the dorsiflexors are assisted by the AFO during GAIT and the activation of the plantarflexion are considerably less during the lifting of the foot of the ground.…

  • Idioma: Inglés

    Editorial: GRIN Verlag Dez 2019, 2019

    3346068277 / 9783346068279

    • Tapa blanda
    • Impresión bajo demanda

    Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 15,95

    Envío por EUR 23,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 2 disponibles

    Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Technical Report from the year 2019 in the subject Engineering - Mechanical Engineering, grade: 10.00, , language: English, abstract: Ankle foot orthosis (AFO) are externally applied device that a reused to support as well as control the foot and ankle joint of patients having foot deformity. Foot drop is caused by a deficiency in the ankle joint in which results in the weakness of ankle and toe dorsiflexion. This research proposes a new approach to design and performance evaluation of AFO fabrication that utilizes modeling, simulation and analysis software (like Open Sim, Ansys Work bench & Solid work) and additive manufacturing technologies to customize the fit form to an individual. By implementing a carbon fibre strut at ankle joint the design will result in a stronger, more comfortable, more flexible AFO that can adaptively constrain ankle movement for various different activities.GAIT Analysis was performed on six patients having foot drop, from the emotion analysis system in the GAIT lab. The data from the GAIT lab was then imported into the Open Sim to create a biomechanics simulation to extract the joint angle and joint moments. These value of ankle angle and moment with & without AFO was compared with normal value. The results show a considerable effect of the use of the AFO by drop foot patients in terms of ankle angle and ankle moments. Furthermore, the muscular analysis in terms of activation and forces also suggest that the dorsiflexors are assisted by the AFO during GAIT and the activation of the plantarflexion are considerably less during the lifting of the foot of the ground. 16 pp. Englisch.…

  • Idioma: Inglés

    Editorial: GRIN Verlag Dez 2019, 2019

    3346068277 / 9783346068279

    • Tapa blanda
    • Impresión bajo demanda

    Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 15,95

    Envío por EUR 60,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Technical Report from the year 2019 in the subject Engineering - Mechanical Engineering, grade: 10.00, , language: English, abstract: Ankle foot orthosis (AFO) are externally applied device that a reused to support as well as control the foot and ankle joint of patients having foot deformity. Foot drop is caused by a deficiency in the ankle joint in which results in the weakness of ankle and toe dorsiflexion. This research proposes a new approach to design and performance evaluation of AFO fabrication that utilizes modeling, simulation and analysis software (like Open Sim, Ansys Work bench & Solid work) and additive manufacturing technologies to customize the fit form to an individual. By implementing a carbon fibre strut at ankle joint the design will result in a stronger, more comfortable, more flexible AFO that can adaptively constrain ankle movement for various different activities.GAIT Analysis was performed on six patients having foot drop, from the emotion analysis system in the GAIT lab. The data from the GAIT lab was then imported into the Open Sim to create a biomechanics simulation to extract the joint angle and joint moments. These value of ankle angle and moment with & without AFO was compared with normal value. The results show a considerable effect of the use of the AFO by drop foot patients in terms of ankle angle and ankle moments. Furthermore, the muscular analysis in terms of activation and forces also suggest that the dorsiflexors are assisted by the AFO during GAIT and the activation of the plantarflexion are considerably less during the lifting of the foot of the ground.GRIN Publishing GmbH, Waltherstraße 23, 80337 München 16 pp. Englisch.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2017

    3330324724 / 9783330324725

    • Tapa blanda
    • Impresión bajo demanda

    Librería: moluna, Greven, Alemaniamoluna

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 52,90

    Envío por EUR 48,99 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Bajwa Gurvinder SinghGurvinder Singh Bajwa? Ph.D in the field of Electronics from Monad University, Hapur, 2013? M-Tech Total Quality Engineering and Management from PEC University Chandigarh? M-Tech Electronics and Telecommunication.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2017

    3330324724 / 9783330324725

    • Tapa blanda
    • Impresión bajo demanda

    Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 72,42

    Envío por EUR 35,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Incoherent scattering is one of the major processes by which gamma rays interact with matter in the energy range from 100 KeV to I MeV. The effect was simultaneously but separately observed by Compton (1923) and Debye (1923) based on Einstein's light quantum hypothesis. Debye suggested that the effect should bear Compton's name alone and hence it was named 'Compton effect'. Tabulations are presented of the atomic form factor, F ( , Z), and the incoherent scattering function, S (x, Z), for values of x (=sin /2)/ ) from 0.005 Å-1 to 109 Å-1, for all elements A=1 to 100. These tables are constructed from available state-of-the-art theoretical data, including the Pirenne formulas for Z=1, configuration-into action results by Brown using Brown-Fontana and Weiss correlated wave functions for Z=2 to 6 non-relativistic Hartree-Fock results by Cromer for Z=7 to 100 and a relativistic K-shell analytic expression for F(x, Z) by Bethe Levinger for x 10 Å-1 for all elements Z=2 to 100. These tabulated values are graphically compared with available photon scattering angular distribution measurements. …