Technical Report from the year 2019 in the subject Engineering - Mechanical Engineering, grade: 10.00, , language: English, abstract: Ankle foot orthosis (AFO) are externally applied device that a reused to support as well as control the foot and ankle joint of patients having foot deformity. Foot drop is caused by a deficiency in the ankle joint in which results in the weakness of ankle and toe dorsiflexion. This research proposes a new approach to design and performance evaluation of AFO fabrication that utilizes modeling, simulation and analysis software (like Open Sim, Ansys Work bench & Solid work) and additive manufacturing technologies to customize the fit form to an individual. By implementing a carbon fibre strut at ankle joint the design will result in a stronger, more comfortable, more flexible AFO that can adaptively constrain ankle movement for various different activities. GAIT Analysis was performed on six patients having foot drop, from the emotion analysis system in the GAIT lab. The data from the GAIT lab was then imported into the Open Sim to create a biomechanics simulation to extract the joint angle and joint moments. These value of ankle angle and moment with & without AFO was compared with normal value. The results show a considerable effect of the use of the AFO by drop foot patients in terms of ankle angle and ankle moments. Furthermore, the muscular analysis in terms of activation and forces also suggest that the dorsiflexors are assisted by the AFO during GAIT and the activation of the plantarflexion are considerably less during the lifting of the foot of the ground.
"Sinopsis" puede pertenecer a otra edición de este libro.
Dr. Harish Kumar Banga is presently working as an Assistant Professor in the Department of Production & Industrial engineering at PEC Chandigarh and completed his Ph.D. in the Department of Production & Industrial Engineering from Punjab Engineering College, Chandigarh.Specialization in the area of Additive Manufacturing, Human Engineering, CAD/CAM, Robotics.
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Technical Report from the year 2019 in the subject Engineering - Mechanical Engineering, grade: 10.00, , language: English, abstract: Ankle foot orthosis (AFO) are externally applied device that a reused to support as well as control the foot and ankle joint of patients having foot deformity. Foot drop is caused by a deficiency in the ankle joint in which results in the weakness of ankle and toe dorsiflexion. This research proposes a new approach to design and performance evaluation of AFO fabrication that utilizes modeling, simulation and analysis software (like Open Sim, Ansys Work bench & Solid work) and additive manufacturing technologies to customize the fit form to an individual. By implementing a carbon fibre strut at ankle joint the design will result in a stronger, more comfortable, more flexible AFO that can adaptively constrain ankle movement for various different activities.GAIT Analysis was performed on six patients having foot drop, from the emotion analysis system in the GAIT lab. The data from the GAIT lab was then imported into the Open Sim to create a biomechanics simulation to extract the joint angle and joint moments. These value of ankle angle and moment with & without AFO was compared with normal value. The results show a considerable effect of the use of the AFO by drop foot patients in terms of ankle angle and ankle moments. Furthermore, the muscular analysis in terms of activation and forces also suggest that the dorsiflexors are assisted by the AFO during GAIT and the activation of the plantarflexion are considerably less during the lifting of the foot of the ground. 16 pp. Englisch. Nº de ref. del artículo: 9783346068279
Cantidad disponible: 2 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. Druck auf Anfrage Neuware - Printed after ordering - Technical Report from the year 2019 in the subject Engineering - Mechanical Engineering, grade: 10.00, , language: English, abstract: Ankle foot orthosis (AFO) are externally applied device that a reused to support as well as control the foot and ankle joint of patients having foot deformity. Foot drop is caused by a deficiency in the ankle joint in which results in the weakness of ankle and toe dorsiflexion. This research proposes a new approach to design and performance evaluation of AFO fabrication that utilizes modeling, simulation and analysis software (like Open Sim, Ansys Work bench & Solid work) and additive manufacturing technologies to customize the fit form to an individual. By implementing a carbon fibre strut at ankle joint the design will result in a stronger, more comfortable, more flexible AFO that can adaptively constrain ankle movement for various different activities.GAIT Analysis was performed on six patients having foot drop, from the emotion analysis system in the GAIT lab. The data from the GAIT lab was then imported into the Open Sim to create a biomechanics simulation to extract the joint angle and joint moments. These value of ankle angle and moment with & without AFO was compared with normal value. The results show a considerable effect of the use of the AFO by drop foot patients in terms of ankle angle and ankle moments. Furthermore, the muscular analysis in terms of activation and forces also suggest that the dorsiflexors are assisted by the AFO during GAIT and the activation of the plantarflexion are considerably less during the lifting of the foot of the ground. Nº de ref. del artículo: 9783346068279
Cantidad disponible: 1 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Technical Report from the year 2019 in the subject Engineering - Mechanical Engineering, grade: 10.00, , language: English, abstract: Ankle foot orthosis (AFO) are externally applied device that a reused to support as well as control the foot and ankle joint of patients having foot deformity. Foot drop is caused by a deficiency in the ankle joint in which results in the weakness of ankle and toe dorsiflexion. This research proposes a new approach to design and performance evaluation of AFO fabrication that utilizes modeling, simulation and analysis software (like Open Sim, Ansys Work bench & Solid work) and additive manufacturing technologies to customize the fit form to an individual. By implementing a carbon fibre strut at ankle joint the design will result in a stronger, more comfortable, more flexible AFO that can adaptively constrain ankle movement for various different activities.GAIT Analysis was performed on six patients having foot drop, from the emotion analysis system in the GAIT lab. The data from the GAIT lab was then imported into the Open Sim to create a biomechanics simulation to extract the joint angle and joint moments. These value of ankle angle and moment with & without AFO was compared with normal value. The results show a considerable effect of the use of the AFO by drop foot patients in terms of ankle angle and ankle moments. Furthermore, the muscular analysis in terms of activation and forces also suggest that the dorsiflexors are assisted by the AFO during GAIT and the activation of the plantarflexion are considerably less during the lifting of the foot of the ground.GRIN Publishing GmbH, Waltherstraße 23, 80337 München 16 pp. Englisch. Nº de ref. del artículo: 9783346068279
Cantidad disponible: 1 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Optimized Design and Testing of Kids Ankle Foot Orthosis. A Case Study | Harish Kumar Banga (u. a.) | Taschenbuch | 16 S. | Englisch | 2019 | GRIN Verlag | EAN 9783346068279 | Verantwortliche Person für die EU: GRIN Publishing GmbH, Waltherstr. 23, 80337 München, info[at]grin[dot]com | Anbieter: preigu Print on Demand. Nº de ref. del artículo: 117899225
Cantidad disponible: 5 disponibles