Stability indicating assay method de shingade sunil (5 resultados)

Autor: 
Título: 
Refinar con la Búsqueda avanzada

Filtrar la búsqueda

  • Libros (5)

  • Nuevo (5)

a

Intervalo de precios personalizado (EUR)

a

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2017

    3659692751 / 9783659692758

    • Tapa blanda

    Librería: preigu, Osnabrück, Alemaniapreigu

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 44,10

    Envío por EUR 70,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 5 disponibles

    Taschenbuch. Condición: Neu. Stability Indicating Assay Method Development of Fingolimod | Sunil Shingade (u. a.) | Taschenbuch | 100 S. | Englisch | 2017 | LAP LAMBERT Academic Publishing | EAN 9783659692758 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing Okt 2017, 2017

    3659692751 / 9783659692758

    • Tapa blanda
    • Impresión bajo demanda

    Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 49,90

    Envío por EUR 23,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 2 disponibles

    Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Stress testing of Fingolimod capsules was carried out under acidic, alkaline, peroxide, photolytic, and dry heat conditions. The stressed sample and standard drug were subjected to chromatographic separation and the conditions required for resolving the drug peak from any potential degradation products were optimized. The HPLC analysis of Fingolimod Capsules was carried out using X-Bridge (250mm x 4.6 mm, 5µm) during the stress studies Fingolimod Capsules were found to be stable degrade under acidic, alkaline, peroxide, photolytic and heat conditions. The degradation products and tablet excipients were well resolved from the drug using mobile phase comprising of Buffer:ACN (30:70v/v). The detection wavelength was 220 nm. The developed method was validated as per ICH Guide lines. The method was found to be accurate, precise, robust and linear in the range of 2-14µg/ml. Accuracy was calculated at three levels:50 %, 100%, 150% and recovery was found to be between 95-105%. It can be concluded that the HPLC method developed for Fingolimod Capsules is capable of discriminating between the drug and degradation products. 100 pp. Englisch.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2017

    3659692751 / 9783659692758

    • Tapa blanda
    • Impresión bajo demanda

    Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 52,54

    Envío por EUR 35,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponibles

    Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Stress testing of Fingolimod capsules was carried out under acidic, alkaline, peroxide, photolytic, and dry heat conditions. The stressed sample and standard drug were subjected to chromatographic separation and the conditions required for resolving the drug peak from any potential degradation products were optimized. The HPLC analysis of Fingolimod Capsules was carried out using X-Bridge (250mm x 4.6 mm, 5µm) during the stress studies Fingolimod Capsules were found to be stable degrade under acidic, alkaline, peroxide, photolytic and heat conditions. The degradation products and tablet excipients were well resolved from the drug using mobile phase comprising of Buffer:ACN (30:70v/v). The detection wavelength was 220 nm. The developed method was validated as per ICH Guide lines. The method was found to be accurate, precise, robust and linear in the range of 2-14µg/ml. Accuracy was calculated at three levels:50 %, 100%, 150% and recovery was found to be between 95-105%. It can be concluded that the HPLC method developed for Fingolimod Capsules is capable of discriminating between the drug and degradation products.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2017

    3659692751 / 9783659692758

    • Tapa blanda
    • Impresión bajo demanda

    Librería: moluna, Greven, Alemaniamoluna

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 41,71

    Envío por EUR 48,99 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Shingade SunilDr. Sunil G. Shingade obtained his M. Pharm. degree from Rajiv Gandhi University of Health Sciences, Bangalore, India and Ph. D. in Pharmacy from North Maharashtra University, Jalgaon, India. He is Assistant Professor o.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing Okt 2017, 2017

    3659692751 / 9783659692758

    • Tapa blanda
    • Impresión bajo demanda

    Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 49,90

    Envío por EUR 60,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponibles

    Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Stress testing of Fingolimod capsules was carried out under acidic, alkaline, peroxide, photolytic, and dry heat conditions. The stressed sample and standard drug were subjected to chromatographic separation and the conditions required for resolving the drug peak from any potential degradation products were optimized. The HPLC analysis of Fingolimod Capsules was carried out using X-Bridge (250mm x 4.6 mm, 5µm) during the stress studies Fingolimod Capsules were found to be stable degrade under acidic, alkaline, peroxide, photolytic and heat conditions. The degradation products and tablet excipients were well resolved from the drug using mobile phase comprising of Buffer:ACN (30:70v/v). The detection wavelength was 220 nm. The developed method was validated as per ICH Guide lines. The method was found to be accurate, precise, robust and linear in the range of 2-14µg/ml. Accuracy was calculated at three levels:50 %, 100%, 150% and recovery was found to be between 95-105%. It can be concluded that the HPLC method developed for Fingolimod Capsules is capable of discriminating between the drug and degradation products.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 100 pp. Englisch.…