Full diagnostics inductive plasma de riaby valentin (5 resultados)

Autor: 
Título: 
Refinar con la Búsqueda avanzada

Filtrar la búsqueda

  • Libros (5)

  • Nuevo (5)

a

Intervalo de precios personalizado (EUR)

a

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2018

    6202197382 / 9786202197380

    • Tapa blanda

    Librería: Revaluation Books, Exeter, Reino UnidoRevaluation Books

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 55,48

    Envío por EUR 11,88 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Paperback. Condición: Brand New. 112 pages. 8.66x5.91x0.26 inches. In Stock.

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2018

    6202197382 / 9786202197380

    • Tapa blanda

    Librería: moluna, Greven, Alemaniamoluna

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 26,80

    Envío por EUR 48,99 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    Condición: New.

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing Jan 2018, 2018

    6202197382 / 9786202197380

    • Tapa blanda
    • Impresión bajo demanda

    Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 29,90

    Envío por EUR 23,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 2 disponibles

    Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1's data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield's influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n). 112 pp. Englisch.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2018

    6202197382 / 9786202197380

    • Tapa blanda
    • Impresión bajo demanda

    Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 35,74

    Envío por EUR 35,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1's data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield's influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n). …

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing Jan 2018, 2018

    6202197382 / 9786202197380

    • Tapa blanda
    • Impresión bajo demanda

    Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 29,90

    Envío por EUR 60,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1's data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield's influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n).VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 112 pp. Englisch.…