ISBN: 9798189051623 - commercial load calculation handbook: master hvac sizing, heat pump design, ventilation loads, envelope performance, electrification strategies, and ... across all scales of building projects (6 resultados)

ISBN: 
Refinar con la Búsqueda avanzada

Filtrar la búsqueda

  • Libros (6)

  • Nuevo (6)

a

Intervalo de precios personalizado (EUR)

a

  • Condición: Nuevo

    EUR 148,51

    Envío por EUR 44,24 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 2 disponibles

    Taschenbuch. Condición: Neu. Neuware - Most commercial HVAC engineers learned load calculation from textbooks written for a different era - one without low-GWP refrigerant mandates, electrification requirements, or energy codes that penalise oversized systems.Are you still sizing commercial systems using methods that predate A2L refrigerants and the latest energy codes Do you struggle to verify the numbers your software produces, or defend your equipment selections when a plan reviewer asks you to show your work When a client asks whether their building qualifies for an all-electric heat pump system, do you have a calculation-backed answer ready The commercial HVAC landscape has changed faster in the past five years than in the previous three decades. A2L refrigerants are now the baseline for most equipment categories. Heat pump electrification is a code-driven expectation on projects of every size. A load calculation that passed review five years ago may no longer support a compliant design today.This handbook delivers a complete, sequential, calculation-based workflow - from heat transfer fundamentals and psychrometrics through envelope loads, solar heat gain, internal gains, ventilation, and infiltration, assembling everything into zone cooling and heating load calculations, then extending into variable refrigerant flow sizing, heat pump balance-point analysis, A2L safety compliance, energy code pathways, and a fully integrated case study of a mixed-use commercial building.Readers will be able to: - Calculate block and zone cooling loads with full unit tracking and code-correct inputs- Size and correct variable refrigerant flow systems for actual project conditions- Determine balance points and supplemental heating requirements for air-source heat pump installations- Evaluate A2L charge limits, ventilation requirements, and detection thresholds for compliance- Demonstrate energy code compliance for envelope assemblies and mechanical systems- Construct a complete load calculation package ready for permit submission and peer review- Apply psychrometric analysis to coil selection and humidity control on real projectsEngineers who depend on software outputs they cannot verify are increasingly at a disadvantage as clients and reviewers demand documented answers. As electrification and refrigerant regulations become standard on every project, fluency in these methods shifts from a differentiator to a baseline expectation. The engineers who build this fluency now will be leading project teams while others are still catching up.Get your copy today and start calculating with the confidence that comes from understanding every number you put on paper.…

  • Idioma: Inglés

    Editorial: Independently Published, 2026

    9798189051623

    • Tapa blanda
    • Impresión bajo demanda

    Librería: Grand Eagle Retail, Bensenville, IL, Estados Unidos de AmericaGrand Eagle Retail

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 88,42

     Gastos de envío gratis 
    Se envía dentro de Estados Unidos de America

    Cantidad disponible: 1 disponible

    Paperback. Condición: new. Paperback. Most commercial HVAC engineers learned load calculation from textbooks written for a different era - one without low-GWP refrigerant mandates, electrification requirements, or energy codes that penalise oversized systems.Are you still sizing commercial systems using methods that predate A2L refrigerants and the latest energy codes? Do you struggle to verify the numbers your software produces, or defend your equipment selections when a plan reviewer asks you to show your work? When a client asks whether their building qualifies for an all-electric heat pump system, do you have a calculation-backed answer ready?The commercial HVAC landscape has changed faster in the past five years than in the previous three decades. A2L refrigerants are now the baseline for most equipment categories. Heat pump electrification is a code-driven expectation on projects of every size. A load calculation that passed review five years ago may no longer support a compliant design today.This handbook delivers a complete, sequential, calculation-based workflow - from heat transfer fundamentals and psychrometrics through envelope loads, solar heat gain, internal gains, ventilation, and infiltration, assembling everything into zone cooling and heating load calculations, then extending into variable refrigerant flow sizing, heat pump balance-point analysis, A2L safety compliance, energy code pathways, and a fully integrated case study of a mixed-use commercial building.Readers will be able to: Calculate block and zone cooling loads with full unit tracking and code-correct inputsSize and correct variable refrigerant flow systems for actual project conditionsDetermine balance points and supplemental heating requirements for air-source heat pump installationsEvaluate A2L charge limits, ventilation requirements, and detection thresholds for complianceDemonstrate energy code compliance for envelope assemblies and mechanical systemsConstruct a complete load calculation package ready for permit submission and peer reviewApply psychrometric analysis to coil selection and humidity control on real projectsEngineers who depend on software outputs they cannot verify are increasingly at a disadvantage as clients and reviewers demand documented answers. As electrification and refrigerant regulations become standard on every project, fluency in these methods shifts from a differentiator to a baseline expectation. The engineers who build this fluency now will be leading project teams while others are still catching up.Get your copy today and start calculating with the confidence that comes from understanding every number you put on paper. This item is printed on demand. Shipping may be from multiple locations in the US or from the UK, depending on stock availability.…

  • Idioma: Inglés

    Editorial: Independently published, 2026

    9798189051623

    • Tapa blanda
    • Impresión bajo demanda

    Librería: California Books, Miami, FL, Estados Unidos de AmericaCalifornia Books

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 85,66

    Envío por EUR 2,68 
    Se envía dentro de Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    Condición: New. Print on Demand.

  • Idioma: Inglés

    Editorial: Amazon Digital Services LLC - Kdp, 2026

    9798189051623

    • Tapa blanda
    • Impresión bajo demanda

    Librería: PBShop.store UK, Fairford, GLOS, Reino UnidoPBShop.store UK

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 101,89

    Envío por EUR 9,13 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    PAP. Condición: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.

  • Idioma: Inglés

    Editorial: Amazon Digital Services LLC - Kdp, 2026

    9798189051623

    • Tapa blanda
    • Impresión bajo demanda

    Librería: PBShop.store US, Wood Dale, IL, Estados Unidos de AmericaPBShop.store US

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 111,49

     Gastos de envío gratis 
    Se envía dentro de Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    PAP. Condición: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.

  • Idioma: Inglés

    Editorial: Independently Published, 2026

    9798189051623

    • Tapa blanda
    • Impresión bajo demanda

    Librería: CitiRetail, Stevenage, Reino UnidoCitiRetail

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 109,04

    Envío por EUR 44,26 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Paperback. Condición: new. Paperback. Most commercial HVAC engineers learned load calculation from textbooks written for a different era - one without low-GWP refrigerant mandates, electrification requirements, or energy codes that penalise oversized systems.Are you still sizing commercial systems using methods that predate A2L refrigerants and the latest energy codes? Do you struggle to verify the numbers your software produces, or defend your equipment selections when a plan reviewer asks you to show your work? When a client asks whether their building qualifies for an all-electric heat pump system, do you have a calculation-backed answer ready?The commercial HVAC landscape has changed faster in the past five years than in the previous three decades. A2L refrigerants are now the baseline for most equipment categories. Heat pump electrification is a code-driven expectation on projects of every size. A load calculation that passed review five years ago may no longer support a compliant design today.This handbook delivers a complete, sequential, calculation-based workflow - from heat transfer fundamentals and psychrometrics through envelope loads, solar heat gain, internal gains, ventilation, and infiltration, assembling everything into zone cooling and heating load calculations, then extending into variable refrigerant flow sizing, heat pump balance-point analysis, A2L safety compliance, energy code pathways, and a fully integrated case study of a mixed-use commercial building.Readers will be able to: Calculate block and zone cooling loads with full unit tracking and code-correct inputsSize and correct variable refrigerant flow systems for actual project conditionsDetermine balance points and supplemental heating requirements for air-source heat pump installationsEvaluate A2L charge limits, ventilation requirements, and detection thresholds for complianceDemonstrate energy code compliance for envelope assemblies and mechanical systemsConstruct a complete load calculation package ready for permit submission and peer reviewApply psychrometric analysis to coil selection and humidity control on real projectsEngineers who depend on software outputs they cannot verify are increasingly at a disadvantage as clients and reviewers demand documented answers. As electrification and refrigerant regulations become standard on every project, fluency in these methods shifts from a differentiator to a baseline expectation. The engineers who build this fluency now will be leading project teams while others are still catching up.Get your copy today and start calculating with the confidence that comes from understanding every number you put on paper. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability.…