ISBN: 9798171532444 - hvac commissioning and field diagnostics: a practical guide to startup, testing, balancing, system verification, and troubleshooting (6 resultados)

- Tapa blanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 139,21
Envío por EUR 35,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. Neuware - A heating, ventilating, and air-conditioning system can look finished and still fail at the one thing that matters: performing as it was designed to. A fan runs, air moves, and a space feels roughly comfortable while the same system quietly moves the wrong quantity of air, admits the wrong fraction of outdoor air, and consumes far more energy than intended. None of it announces itself. It becomes visible only through deliberate measurement and honest comparison against the documented design intent - and closing that gap is the work of commissioning and field diagnostics. Too often the knowledge needed to close it is scattered across separate specialties, competing standards, and checklists that can be completed without ever being understood. A technician who balances an air system without grasping the relationship between fan speed, airflow, and pressure is only turning dampers; a troubleshooter working without a verification baseline is only guessing. This guide brings the two disciplines together as one continuous practice: commissioning confirms whether a system meets its requirements, diagnostics explains why it does not when it falls short, and both rely on the same instruments, the same governing relationships, and the same disciplined measurement. Organized in the natural order of a commissioning engagement, the book gives you the reasoning and the concrete procedures to carry an evaluation from an unexplained symptom through to an identified cause and a verified correction. What you will be able to do - Build a measurement foundation you can defend - accuracy, uncertainty budgets, calibration, and the field errors that corrupt readings.- Balance airside and waterside systems using pitot-static traverse, flow-hood readings, proportional balancing, and fan, pump, and system curves.- Verify air-handling units, chillers, boilers, condenser water, cooling towers, and terminal units against their design intent.- Functionally test controls and sequences of operation, then isolate single, multiple, and intermittent faults with a repeatable diagnostic method.- Confirm performance against acceptance criteria and sustain it through documentation and recommissioning across the building's life.>This book is for mechanical engineers, commissioning providers, test-and-balance and controls technicians, facilities and plant operators, and advanced students and instructors who want one coherent source connecting measurement, verification, and diagnosis. Add this practical field reference to your professional library and start turning scattered procedures into one coherent commissioning-and-diagnostics practice.…

- Tapa blanda
- Impresión bajo demanda
Librería: Grand Eagle Retail, Bensenville, IL, Estados Unidos de AmericaGrand Eagle Retail
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 81,13
Gastos de envío gratisSe envía dentro de Estados Unidos de AmericaCantidad disponible: 1 disponible
Paperback. Condición: new. Paperback. A heating, ventilating, and air-conditioning system can look finished and still fail at the one thing that matters: performing as it was designed to. A fan runs, air moves, and a space feels roughly comfortable while the same system quietly moves the wrong quantity of air, admits the wrong fraction of outdoor air, and consumes far more energy than intended. None of it announces itself. It becomes visible only through deliberate measurement and honest comparison against the documented design intent - and closing that gap is the work of commissioning and field diagnostics. Too often the knowledge needed to close it is scattered across separate specialties, competing standards, and checklists that can be completed without ever being understood. A technician who balances an air system without grasping the relationship between fan speed, airflow, and pressure is only turning dampers; a troubleshooter working without a verification baseline is only guessing. This guide brings the two disciplines together as one continuous practice: commissioning confirms whether a system meets its requirements, diagnostics explains why it does not when it falls short, and both rely on the same instruments, the same governing relationships, and the same disciplined measurement. Organized in the natural order of a commissioning engagement, the book gives you the reasoning and the concrete procedures to carry an evaluation from an unexplained symptom through to an identified cause and a verified correction. What you will be able to do Build a measurement foundation you can defend - accuracy, uncertainty budgets, calibration, and the field errors that corrupt readings.Balance airside and waterside systems using pitot-static traverse, flow-hood readings, proportional balancing, and fan, pump, and system curves.Verify air-handling units, chillers, boilers, condenser water, cooling towers, and terminal units against their design intent.Functionally test controls and sequences of operation, then isolate single, multiple, and intermittent faults with a repeatable diagnostic method.Confirm performance against acceptance criteria and sustain it through documentation and recommissioning across the building's life.Every method is developed from stated assumptions, demonstrated in fully worked examples with complete unit tracking, and reinforced with practice problems, so you gain a durable way of reasoning about performance rather than a set of steps to memorize. Written for United States practice using U.S. customary units with International System values in parentheses. This book is for mechanical engineers, commissioning providers, test-and-balance and controls technicians, facilities and plant operators, and advanced students and instructors who want one coherent source connecting measurement, verification, and diagnosis. Add this practical field reference to your professional library and start turning scattered procedures into one coherent commissioning-and-diagnostics practice. This item is printed on demand. Shipping may be from multiple locations in the US or from the UK, depending on stock availability.…

- Tapa blanda
- Impresión bajo demanda
Librería: California Books, Miami, FL, Estados Unidos de AmericaCalifornia Books
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 79,99
Envío por EUR 2,68Se envía dentro de Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New. Print on Demand.

- Tapa blanda
- Impresión bajo demanda
Librería: PBShop.store UK, Fairford, GLOS, Reino UnidoPBShop.store UK
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 94,96
Envío por EUR 5,99Se envía de Reino Unido a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
PAP. Condición: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.

- Tapa blanda
- Impresión bajo demanda
Librería: PBShop.store US, Wood Dale, IL, Estados Unidos de AmericaPBShop.store US
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 100,80
Gastos de envío gratisSe envía dentro de Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
PAP. Condición: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.

- Tapa blanda
- Impresión bajo demanda
Librería: CitiRetail, Stevenage, Reino UnidoCitiRetail
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 101,44
Envío por EUR 44,18Se envía de Reino Unido a Estados Unidos de AmericaCantidad disponible: 1 disponible
Paperback. Condición: new. Paperback. A heating, ventilating, and air-conditioning system can look finished and still fail at the one thing that matters: performing as it was designed to. A fan runs, air moves, and a space feels roughly comfortable while the same system quietly moves the wrong quantity of air, admits the wrong fraction of outdoor air, and consumes far more energy than intended. None of it announces itself. It becomes visible only through deliberate measurement and honest comparison against the documented design intent - and closing that gap is the work of commissioning and field diagnostics. Too often the knowledge needed to close it is scattered across separate specialties, competing standards, and checklists that can be completed without ever being understood. A technician who balances an air system without grasping the relationship between fan speed, airflow, and pressure is only turning dampers; a troubleshooter working without a verification baseline is only guessing. This guide brings the two disciplines together as one continuous practice: commissioning confirms whether a system meets its requirements, diagnostics explains why it does not when it falls short, and both rely on the same instruments, the same governing relationships, and the same disciplined measurement. Organized in the natural order of a commissioning engagement, the book gives you the reasoning and the concrete procedures to carry an evaluation from an unexplained symptom through to an identified cause and a verified correction. What you will be able to do Build a measurement foundation you can defend - accuracy, uncertainty budgets, calibration, and the field errors that corrupt readings.Balance airside and waterside systems using pitot-static traverse, flow-hood readings, proportional balancing, and fan, pump, and system curves.Verify air-handling units, chillers, boilers, condenser water, cooling towers, and terminal units against their design intent.Functionally test controls and sequences of operation, then isolate single, multiple, and intermittent faults with a repeatable diagnostic method.Confirm performance against acceptance criteria and sustain it through documentation and recommissioning across the building's life.Every method is developed from stated assumptions, demonstrated in fully worked examples with complete unit tracking, and reinforced with practice problems, so you gain a durable way of reasoning about performance rather than a set of steps to memorize. Written for United States practice using U.S. customary units with International System values in parentheses. This book is for mechanical engineers, commissioning providers, test-and-balance and controls technicians, facilities and plant operators, and advanced students and instructors who want one coherent source connecting measurement, verification, and diagnosis. Add this practical field reference to your professional library and start turning scattered procedures into one coherent commissioning-and-diagnostics practice. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability.…