9786202081795 - design and optimization of a mems-based piezoresistive accelerometer: computational analysis of a mems-based accelerometer with silicon nanowire piezoresistors for head injuries monitoring de messina, marco; njuguna, james (6 resultados)
- Más imágenes
- Tapa blanda
Librería: preigu, Osnabrück, Alemaniapreigu
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 67,20
Envío por EUR 70,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 5 disponibles
Taschenbuch. Condición: Neu. Design and Optimization of a MEMS-Based Piezoresistive Accelerometer | Computational Analysis of a MEMS-Based Accelerometer with Silicon Nanowire Piezoresistors for Head Injuries Monitoring | Marco Messina (u. a.) | Taschenbuch | 324 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN 978620…2081795 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu.
- Tapa blanda
Librería: Revaluation Books, Exeter, Reino UnidoRevaluation Books
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 144,24
Envío por EUR 14,61Se envía de Reino Unido a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Paperback. Condición: Brand New. 324 pages. 8.66x5.91x0.73 inches. In Stock.
- Más imágenes
- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 79,90
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This work focuses on the design improvement of a tri-axial piezoresistive accelerometer specifically designed for head injuries monitoring where medium-G impacts are common, for example in sports such as motorsport and American foot…ball. Given the particular biomedical and biomechanical application the device requires the highest sensitivity achievable with a single proof mass approach, where basically all three axes of measurements are detected with a single mass suspended by surrounding beams. Moreover, a very low error, below 1%, is expected for these type of applications where accuracy is paramount. The optimization method used is based on the progressive increment of the sensor mass moment of inertia (MMI) in all axes. The theoretical hypothesis to confirm is that an increment of MMI of the device proof mass would determine an increment of device sensitivity with a simultaneous reduction of cross-talk in the particular axis under study. The work numerically demonstrates the hypothesis validity by simulating the optimized device mechanical structures with Finite Element Method. A final optimal shape is selected as the best possible output of the optimization process. 324 pp. Englisch.
- Más imágenes
- Tapa blanda
- Impresión bajo demanda
Librería: moluna, Greven, Alemaniamoluna
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 64,09
Envío por EUR 48,99Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Messina MarcoDr Messina has long-standing interest in nanotechnology and MEMS design and development with a patent published at the European Patent Office in 2014. He has extensive research experience i…n Wireless Sensors Networks (II.
- Más imágenes
- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 79,90
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This work focuses on the design improvement of a tri-axial piezoresistive accelerometer specifically designed for head injuries monitoring where medium-G impacts are common, for example in sports such as motorsport and American football…. Given the particular biomedical and biomechanical application the device requires the highest sensitivity achievable with a single proof mass approach, where basically all three axes of measurements are detected with a single mass suspended by surrounding beams. Moreover, a very low error, below 1%, is expected for these type of applications where accuracy is paramount. The optimization method used is based on the progressive increment of the sensor mass moment of inertia (MMI) in all axes. The theoretical hypothesis to confirm is that an increment of MMI of the device proof mass would determine an increment of device sensitivity with a simultaneous reduction of cross-talk in the particular axis under study. The work numerically demonstrates the hypothesis validity by simulating the optimized device mechanical structures with Finite Element Method. A final optimal shape is selected as the best possible output of the optimization process.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 324 pp. Englisch.
- Más imágenes
- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 80,86
Envío por EUR 62,50Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This work focuses on the design improvement of a tri-axial piezoresistive accelerometer specifically designed for head injuries monitoring where medium-G impacts are common, for example in sports such as motorsport and American football.… Given the particular biomedical and biomechanical application the device requires the highest sensitivity achievable with a single proof mass approach, where basically all three axes of measurements are detected with a single mass suspended by surrounding beams. Moreover, a very low error, below 1%, is expected for these type of applications where accuracy is paramount. The optimization method used is based on the progressive increment of the sensor mass moment of inertia (MMI) in all axes. The theoretical hypothesis to confirm is that an increment of MMI of the device proof mass would determine an increment of device sensitivity with a simultaneous reduction of cross-talk in the particular axis under study. The work numerically demonstrates the hypothesis validity by simulating the optimized device mechanical structures with Finite Element Method. A final optimal shape is selected as the best possible output of the optimization process.





