9786200482471 - bio-analytical method development of antimalarial drug in human plasma: validation for quantitative estimation by using lc-msms de abraham, bincy; chaki, imran; pujara, naisarg (6 resultados)

- Tapa blanda
Librería: Revaluation Books, Exeter, Reino UnidoRevaluation Books
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 95,18
Envío por EUR 11,70Se envía de Reino Unido a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Paperback. Condición: Brand New. 128 pages. 8.66x5.91x0.29 inches. In Stock.

- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 54,90
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In the present work new, simple reversed-phase LCMS/MS in positive ion mode method was developed and validated for the determination of an anti-malarial in blood plasma. Drug was used as an internal standard. The chromatographic sep…aration was achieved with Zorbax SB-C18, 5.0µm (150\*4.6mm). The separation of Drug H was achieved by gradient elution using organic mixture (Acetonitrile: Methanol::80:20 v/v), buffer solution (10mM Ammonium Formate) and DMSO:: 50:50:0.2 v/v/v. The flow rate is 1.000 ml/min, Injection Volume of 10µl with a run time of 3.0 minutes. The calibration curve of standard Drug H was linear in range 0.1-20.0 ¿g/ml. 5 precision and accuracy batches were run; the coefficient of correlation (r2) was ¿ 0.99. The accuracy of the LLOQ in the standard CC was within ± 20% of the nominal concentration and ± 15% of the nominal concentration for other standards and 75% non- zero calibration standards met the acceptable criteria which indicated the method was precise and accurate. Method validation results have proved the method to be selective, sensitive, precise, accurate and robustness. 128 pp. Englisch.

- Tapa blanda
- Impresión bajo demanda
Librería: moluna, Greven, Alemaniamoluna
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 45,45
Envío por EUR 48,99Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Abraham BincyBINCY ABRAHAM, Master of Pharmacy in Quality Assurance from Jaipur National University, Jaipur, Rajasthan.In the present work new, simple reversed-phase LCMS/MS in positive ion mode method…was developed and validated.

- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 54,90
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In the present work new, simple reversed-phase LCMS/MS in positive ion mode method was developed and validated for the determination of an anti-malarial in blood plasma. Drug was used as an internal standard. The chromatographic separat…ion was achieved with Zorbax SB-C18, 5.0µm (150\*4.6mm). The separation of Drug H was achieved by gradient elution using organic mixture (Acetonitrile: Methanol::80:20 v/v), buffer solution (10mM Ammonium Formate) and DMSO:: 50:50:0.2 v/v/v. The flow rate is 1.000 ml/min, Injection Volume of 10µl with a run time of 3.0 minutes. The calibration curve of standard Drug H was linear in range 0.1-20.0 ¿g/ml. 5 precision and accuracy batches were run; the coefficient of correlation (r2) was ¿ 0.99. The accuracy of the LLOQ in the standard CC was within ± 20% of the nominal concentration and ± 15% of the nominal concentration for other standards and 75% non- zero calibration standards met the acceptable criteria which indicated the method was precise and accurate. Method validation results have proved the method to be selective, sensitive, precise, accurate and robustness.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 128 pp. Englisch.

- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 55,56
Envío por EUR 61,05Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In the present work new, simple reversed-phase LCMS/MS in positive ion mode method was developed and validated for the determination of an anti-malarial in blood plasma. Drug was used as an internal standard. The chromatographic separati…on was achieved with Zorbax SB-C18, 5.0µm (150\*4.6mm). The separation of Drug H was achieved by gradient elution using organic mixture (Acetonitrile: Methanol::80:20 v/v), buffer solution (10mM Ammonium Formate) and DMSO:: 50:50:0.2 v/v/v. The flow rate is 1.000 ml/min, Injection Volume of 10µl with a run time of 3.0 minutes. The calibration curve of standard Drug H was linear in range 0.1-20.0 ¿g/ml. 5 precision and accuracy batches were run; the coefficient of correlation (r2) was ¿ 0.99. The accuracy of the LLOQ in the standard CC was within ± 20% of the nominal concentration and ± 15% of the nominal concentration for other standards and 75% non- zero calibration standards met the acceptable criteria which indicated the method was precise and accurate. Method validation results have proved the method to be selective, sensitive, precise, accurate and robustness.

- Tapa blanda
- Impresión bajo demanda
Librería: preigu, Osnabrück, Alemaniapreigu
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 47,20
Envío por EUR 70,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 5 disponibles
Taschenbuch. Condición: Neu. Bio-analytical method development of antimalarial drug in human plasma | Validation for quantitative estimation by using LC-MSMS | Bincy Abraham (u. a.) | Taschenbuch | Englisch | 2019 | LAP LAMBERT Academic Publishing | EAN 9786200482471 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Len…gericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu Print on Demand.