ISBN: 9783846502693 - development of a method to measure tep on fresh & saline water: development of a method to measure transparent exopolymer particles (tep): fresh and saline water applications (8 resultados)

- Tapa blanda
Librería: Books Puddle, Woodside, NY, Estados Unidos de AmericaBooks Puddle
Contactar con el vendedorVendedor de 4 estrellasCondición: Nuevo
EUR 80,97
Envío por EUR 3,58Se envía dentro de Estados Unidos de AmericaCantidad disponible: 4 disponibles
Condición: New. pp. 112.

- Tapa blanda
Librería: preigu, Osnabrück, Alemaniapreigu
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 41,40
Envío por EUR 70,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 5 disponibles
Taschenbuch. Condición: Neu. Development of a method to measure TEP on fresh & saline water | Development of a method to measure transparent exopolymer particles (TEP): fresh and saline water applications | Ramesh Duraisamy | Taschenbuch | 112 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783846502693 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 49,00
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The ubiquitous presence of transparent exopolymer particles (TEP) in various water sources of membrane-based treatment plants and their ability to adhere to surfaces (high stickiness) and to initiate biofilm formation have led some experts to suggest that TEP may have a major role in organic and biological fouling of membrane systems. This paper aims discuss the latest knowledge on the possible link of TEP to membrane fouling, assess the currently available techniques to identify/measure TEP and how this can be applied in membrane fouling studies. Staining with Alcian blue is so far the most feasible way to assess TEP in water and in fouled membrane samples. Alcian blue was found to react specifically with acidic polysaccharides based on tests with model polysaccharides (neutral and anionic) and protein substances at pH 2.5. Under this condition, the relative concentration of TEP in water can be measured spectrophotometrically at 787 nm wavelength. The current TEP method is also an indirect measure of anion density of TEP, an indication of how surface-active and sticky these substances are; thus, a good indicator of their fouling potential in membrane systems. 112 pp. Englisch.…

- Tapa blanda
- Impresión bajo demanda
Librería: Majestic Books, Hounslow, Reino UnidoMajestic Books
Contactar con el vendedorVendedor de 4 estrellasCondición: Nuevo
EUR 81,39
Envío por EUR 7,80Se envía de Reino Unido a Estados Unidos de AmericaCantidad disponible: 4 disponibles
Condición: New. Print on Demand pp. 112 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam.

- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 54,71
Envío por EUR 35,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponible
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The ubiquitous presence of transparent exopolymer particles (TEP) in various water sources of membrane-based treatment plants and their ability to adhere to surfaces (high stickiness) and to initiate biofilm formation have led some experts to suggest that TEP may have a major role in organic and biological fouling of membrane systems. This paper aims discuss the latest knowledge on the possible link of TEP to membrane fouling, assess the currently available techniques to identify/measure TEP and how this can be applied in membrane fouling studies. Staining with Alcian blue is so far the most feasible way to assess TEP in water and in fouled membrane samples. Alcian blue was found to react specifically with acidic polysaccharides based on tests with model polysaccharides (neutral and anionic) and protein substances at pH 2.5. Under this condition, the relative concentration of TEP in water can be measured spectrophotometrically at 787 nm wavelength. The current TEP method is also an indirect measure of anion density of TEP, an indication of how surface-active and sticky these substances are; thus, a good indicator of their fouling potential in membrane systems.…

- Tapa blanda
- Impresión bajo demanda
Librería: moluna, Greven, Alemaniamoluna
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 41,05
Envío por EUR 48,99Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Duraisamy RameshRamesh Duraisamy is Water Supply Engineer. In 2000 he has completed Bachelor of Civil Engineering from Annamalai University, India. He is working as a Water Supply consultant in India. 2008-2010 he has done MSc in Mun.…

- Tapa blanda
- Impresión bajo demanda
Librería: Biblios, frankfurt am main, HESSE, AlemaniaBiblios
Contactar con el vendedorVendedor de 4 estrellasCondición: Nuevo
EUR 82,22
Envío por EUR 9,95Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 4 disponibles
Condición: New. PRINT ON DEMAND pp. 112.

- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 49,00
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponible
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The ubiquitous presence of transparent exopolymer particles (TEP) in various water sources of membrane-based treatment plants and their ability to adhere to surfaces (high stickiness) and to initiate biofilm formation have led some experts to suggest that TEP may have a major role in organic and biological fouling of membrane systems. This paper aims discuss the latest knowledge on the possible link of TEP to membrane fouling, assess the currently available techniques to identify/measure TEP and how this can be applied in membrane fouling studies. Staining with Alcian blue is so far the most feasible way to assess TEP in water and in fouled membrane samples. Alcian blue was found to react specifically with acidic polysaccharides based on tests with model polysaccharides (neutral and anionic) and protein substances at pH 2.5. Under this condition, the relative concentration of TEP in water can be measured spectrophotometrically at 787 nm wavelength. The current TEP method is also an indirect measure of anion density of TEP, an indication of how surface-active and sticky these substances are; thus, a good indicator of their fouling potential in membrane systems.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 112 pp. Englisch.…