Isbn: 9783844326390 - harmonic source localization in power systems: single and multiple harmonic sources (6 resultados)

ISBN: 
Refinar con la Búsqueda avanzada

Filtrar la búsqueda

  • Libros (6)

a

Intervalo de precios personalizado (EUR)

a

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2011

    3844326391 / 9783844326390

    • Tapa blanda

    Librería: preigu, Osnabrück, Alemaniapreigu

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 51,10

    Envío por EUR 70,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 5 disponibles

    Taschenbuch. Condición: Neu. Harmonic Source Localization in Power Systems | Single and Multiple Harmonic Sources | Masoud Farhoodnea (u. a.) | Taschenbuch | 152 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783844326390 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. …

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2011

    3844326391 / 9783844326390

    • Tapa blanda

    Librería: Mispah books, Redhill, SURRE, Reino UnidoMispah books

    Vendedor de 4 estrellas
    Contactar con el vendedor

    Condición: Usado - Como Nuevo

    EUR 139,92

    Envío por EUR 29,28 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Paperback. Condición: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing Apr 2011, 2011

    3844326391 / 9783844326390

    • Tapa blanda
    • Impresión bajo demanda

    Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 59,00

    Envío por EUR 23,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 2 disponibles

    Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In this book, harmonic source localization methods have been developed by considering two methods. The first method considers a single point measurement strategy for locating dominant harmonic source by determining the harmonic contributions of utility and customer at a single point called as the point of common coupling. This approach is based on a Norton equivalent circuit for simplifying the system under study, and modelling the customer load with parallel RLC components using the measured harmonic voltage and current at the PCC. While, the second method considers a multiple point measurement strategy for locating multiple harmonic sources in a distribution system using independent component analysis (ICA) and mutual information theory (MI). In this method, ICA is used for reconstructing the magnitude of the injected harmonic currents caused by harmonic sources while MI is applied for determining the exact locations of harmonic sources based on the reconstructed harmonic currents. 152 pp. Englisch.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2011

    3844326391 / 9783844326390

    • Tapa blanda
    • Impresión bajo demanda

    Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 61,25

    Envío por EUR 35,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In this book, harmonic source localization methods have been developed by considering two methods. The first method considers a single point measurement strategy for locating dominant harmonic source by determining the harmonic contributions of utility and customer at a single point called as the point of common coupling. This approach is based on a Norton equivalent circuit for simplifying the system under study, and modelling the customer load with parallel RLC components using the measured harmonic voltage and current at the PCC. While, the second method considers a multiple point measurement strategy for locating multiple harmonic sources in a distribution system using independent component analysis (ICA) and mutual information theory (MI). In this method, ICA is used for reconstructing the magnitude of the injected harmonic currents caused by harmonic sources while MI is applied for determining the exact locations of harmonic sources based on the reconstructed harmonic currents.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2011

    3844326391 / 9783844326390

    • Tapa blanda
    • Impresión bajo demanda

    Librería: moluna, Greven, Alemaniamoluna

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 48,50

    Envío por EUR 48,99 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Farhoodnea MasoudMasoud Farhoodnea: received his B.Sc from the Azad University of Najaf Abad, Iran in 2005 and M.Sc in Electrical Engineering from Universiti Kebangsaan Malaysia (UKM) in 2011. Azah Mohamed: received her B.Sc from .…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing Apr 2011, 2011

    3844326391 / 9783844326390

    • Tapa blanda
    • Impresión bajo demanda

    Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 59,00

    Envío por EUR 60,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In this book, harmonic source localization methods have been developed by considering two methods. The first method considers a single point measurement strategy for locating dominant harmonic source by determining the harmonic contributions of utility and customer at a single point called as the point of common coupling. This approach is based on a Norton equivalent circuit for simplifying the system under study, and modelling the customer load with parallel RLC components using the measured harmonic voltage and current at the PCC. While, the second method considers a multiple point measurement strategy for locating multiple harmonic sources in a distribution system using independent component analysis (ICA) and mutual information theory (MI). In this method, ICA is used for reconstructing the magnitude of the injected harmonic currents caused by harmonic sources while MI is applied for determining the exact locations of harmonic sources based on the reconstructed harmonic currents.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 152 pp. Englisch.…