In this book, harmonic source localization methods have been developed by considering two methods. The first method considers a single point measurement strategy for locating dominant harmonic source by determining the harmonic contributions of utility and customer at a single point called as the point of common coupling. This approach is based on a Norton equivalent circuit for simplifying the system under study, and modelling the customer load with parallel RLC components using the measured harmonic voltage and current at the PCC. While, the second method considers a multiple point measurement strategy for locating multiple harmonic sources in a distribution system using independent component analysis (ICA) and mutual information theory (MI). In this method, ICA is used for reconstructing the magnitude of the injected harmonic currents caused by harmonic sources while MI is applied for determining the exact locations of harmonic sources based on the reconstructed harmonic currents.
"Sinopsis" puede pertenecer a otra edición de este libro.
In this book, harmonic source localization methods have been developed by considering two methods. The first method considers a single point measurement strategy for locating dominant harmonic source by determining the harmonic contributions of utility and customer at a single point called as the point of common coupling. This approach is based on a Norton equivalent circuit for simplifying the system under study, and modelling the customer load with parallel RLC components using the measured harmonic voltage and current at the PCC. While, the second method considers a multiple point measurement strategy for locating multiple harmonic sources in a distribution system using independent component analysis (ICA) and mutual information theory (MI). In this method, ICA is used for reconstructing the magnitude of the injected harmonic currents caused by harmonic sources while MI is applied for determining the exact locations of harmonic sources based on the reconstructed harmonic currents.
Masoud Farhoodnea: received his B.Sc from the Azad University of Najaf Abad, Iran in 2005 and M.Sc in Electrical Engineering from Universiti Kebangsaan Malaysia (UKM) in 2011. Azah Mohamed: received her B.Sc from King?s College, University of London in 1978 and M.Sc and Ph.D from Universiti Malaya in 1988 and 1995, respectively.
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In this book, harmonic source localization methods have been developed by considering two methods. The first method considers a single point measurement strategy for locating dominant harmonic source by determining the harmonic contributions of utility and customer at a single point called as the point of common coupling. This approach is based on a Norton equivalent circuit for simplifying the system under study, and modelling the customer load with parallel RLC components using the measured harmonic voltage and current at the PCC. While, the second method considers a multiple point measurement strategy for locating multiple harmonic sources in a distribution system using independent component analysis (ICA) and mutual information theory (MI). In this method, ICA is used for reconstructing the magnitude of the injected harmonic currents caused by harmonic sources while MI is applied for determining the exact locations of harmonic sources based on the reconstructed harmonic currents. 152 pp. Englisch. Nº de ref. del artículo: 9783844326390
Cantidad disponible: 2 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Farhoodnea MasoudMasoud Farhoodnea: received his B.Sc from the Azad University of Najaf Abad, Iran in 2005 and M.Sc in Electrical Engineering from Universiti Kebangsaan Malaysia (UKM) in 2011. Azah Mohamed: received her B.Sc from . Nº de ref. del artículo: 5473045
Cantidad disponible: Más de 20 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In this book, harmonic source localization methods have been developed by considering two methods. The first method considers a single point measurement strategy for locating dominant harmonic source by determining the harmonic contributions of utility and customer at a single point called as the point of common coupling. This approach is based on a Norton equivalent circuit for simplifying the system under study, and modelling the customer load with parallel RLC components using the measured harmonic voltage and current at the PCC. While, the second method considers a multiple point measurement strategy for locating multiple harmonic sources in a distribution system using independent component analysis (ICA) and mutual information theory (MI). In this method, ICA is used for reconstructing the magnitude of the injected harmonic currents caused by harmonic sources while MI is applied for determining the exact locations of harmonic sources based on the reconstructed harmonic currents.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 152 pp. Englisch. Nº de ref. del artículo: 9783844326390
Cantidad disponible: 1 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In this book, harmonic source localization methods have been developed by considering two methods. The first method considers a single point measurement strategy for locating dominant harmonic source by determining the harmonic contributions of utility and customer at a single point called as the point of common coupling. This approach is based on a Norton equivalent circuit for simplifying the system under study, and modelling the customer load with parallel RLC components using the measured harmonic voltage and current at the PCC. While, the second method considers a multiple point measurement strategy for locating multiple harmonic sources in a distribution system using independent component analysis (ICA) and mutual information theory (MI). In this method, ICA is used for reconstructing the magnitude of the injected harmonic currents caused by harmonic sources while MI is applied for determining the exact locations of harmonic sources based on the reconstructed harmonic currents. Nº de ref. del artículo: 9783844326390
Cantidad disponible: 1 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Harmonic Source Localization in Power Systems | Single and Multiple Harmonic Sources | Masoud Farhoodnea (u. a.) | Taschenbuch | 152 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783844326390 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Nº de ref. del artículo: 107031468
Cantidad disponible: 5 disponibles
Librería: Mispah books, Redhill, SURRE, Reino Unido
Paperback. Condición: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Nº de ref. del artículo: ERICA78738443263916
Cantidad disponible: 1 disponibles