ISBN: 9783639710625 - improved islanding detection methods for distributed generators (7 resultados)

- Tapa blanda
Librería: Revaluation Books, Exeter, Reino UnidoRevaluation Books
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 123,68
Envío por EUR 11,95Se envía de Reino Unido a Estados Unidos de AmericaCantidad disponible: 1 disponible
Paperback. Condición: Brand New. 132 pages. 8.66x5.91x0.30 inches. In Stock.

- Tapa blanda
Librería: Mispah books, Redhill, SURRE, Reino UnidoMispah books
Contactar con el vendedorVendedor de 4 estrellasCondición: Nuevo
EUR 205,49
Envío por EUR 29,87Se envía de Reino Unido a Estados Unidos de AmericaCantidad disponible: 1 disponible
paperback. Condición: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Tapa blanda
Librería: preigu, Osnabrück, Alemaniapreigu
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 271,60
Envío por EUR 70,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 5 disponibles
Taschenbuch. Condición: Neu. Improved Islanding Detection Methods For Distributed Generators | Smita Shrivastava (u. a.) | Taschenbuch | Englisch | 2017 | Scholars' Press | EAN 9783639710625 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. …

- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 67,90
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Islanding detection is an essential requirement of the modified power system scenario with increased penetration of DGs. A new detection technique based on wavelet energy entropy identification and active frequency drift confirmation approach has been proposed. Wavelet energy entropy is proposed as a solid indicator for possible islanding operation. As an active approach, frequency drift anti-islanding algorithm is proposed robustly shift the voltage frequency into the tripping window. The proposed method reduces time of detection leading to reliability. The technique also reduces non detection zone of passive method approximately to zero. These benefits of proposed method not only improve dependability of the detection but also overcome the power quality degradation issue of active method, as perturbation is not applied continuously in the system. The time taken by this dual level approach is much shorter than other hybrid methods as response time of wavelet entropy indicator is in ms and speed of active frequency drift is improved by adjusting parameters without any restriction on power quality degradation. 132 pp. Englisch.…

- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 67,90
Envío por EUR 35,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponible
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Islanding detection is an essential requirement of the modified power system scenario with increased penetration of DGs. A new detection technique based on wavelet energy entropy identification and active frequency drift confirmation approach has been proposed. Wavelet energy entropy is proposed as a solid indicator for possible islanding operation. As an active approach, frequency drift anti-islanding algorithm is proposed robustly shift the voltage frequency into the tripping window. The proposed method reduces time of detection leading to reliability. The technique also reduces non detection zone of passive method approximately to zero. These benefits of proposed method not only improve dependability of the detection but also overcome the power quality degradation issue of active method, as perturbation is not applied continuously in the system. The time taken by this dual level approach is much shorter than other hybrid methods as response time of wavelet entropy indicator is in ms and speed of active frequency drift is improved by adjusting parameters without any restriction on power quality degradation.…

- Tapa blanda
- Impresión bajo demanda
Librería: moluna, Greven, Alemaniamoluna
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 56,01
Envío por EUR 48,99Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Shrivastava SmitaSmita Shrivastava received her B.E. and M.E. Degree from Government Engineering College Jabalpur India, and the Ph.D. degree from National Institute of Technology Bhopal India. Currently she is Professor in Hitkarini.…

- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 271,60
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponible
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Islanding detection is an essential requirement of the modified power system scenario with increased penetration of DGs. A new detection technique based on wavelet energy entropy identification and active frequency drift confirmation approach has been proposed. Wavelet energy entropy is proposed as a solid indicator for possible islanding operation. As an active approach, frequency drift anti-islanding algorithm is proposed robustly shift the voltage frequency into the tripping window. The proposed method reduces time of detection leading to reliability. The technique also reduces non detection zone of passive method approximately to zero. These benefits of proposed method not only improve dependability of the detection but also overcome the power quality degradation issue of active method, as perturbation is not applied continuously in the system. The time taken by this dual level approach is much shorter than other hybrid methods as response time of wavelet entropy indicator is in ms and speed of active frequency drift is improved by adjusting parameters without any restriction on power quality degradation.OmniScriptum SRL, Str. Armeneasca 28/1, office 1, 2012 Chisinau 132 pp. Englisch.…