ISBN: 9783330853287 - seismic capacity assessment of rc buildings by using pushover analysis (6 resultados)

- Tapa blanda
Librería: Revaluation Books, Exeter, Reino UnidoRevaluation Books
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 85,63
Envío por EUR 11,99Se envía de Reino Unido a Estados Unidos de AmericaCantidad disponible: 1 disponible
Paperback. Condición: Brand New. 116 pages. 8.66x5.91x0.27 inches. In Stock.

- Tapa blanda
Librería: preigu, Osnabrück, Alemaniapreigu
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 36,60
Envío por EUR 70,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 5 disponibles
Taschenbuch. Condición: Neu. Seismic Capacity Assessment of RC Buildings by Using Pushover Analysis | Mohammed Ahmed Ismaeil Abunama | Taschenbuch | 116 S. | Englisch | 2017 | Noor Publishing | EAN 9783330853287 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. …

- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 39,90
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The aim of this book is to evaluate seismic performance of existing low-to-mid-rise Reinforced Concrete (RC) frame buildings. The buildings, which consist of 4, 6, 8, and 10 stories, are designed according to British standard code (BSI) and American code (ACI).Pushover analysis has been performed according to FEMA-356 guidelines;the pushover analysis is used.The lateral load patterns for pushover analysis are selected as the Regulations for earthquake resistant design of building in Egypt, 1988; these regulations have been prepared by the Egyptian Society for Earthquake Engineering (ESEE) and International Building Code (IBC 2012). Results showed that the buildings designed considering the ESEE and IBC 2012 loads were found adequate. On the other hand, the building designed according to (ESEE using BSI) satisfies the Immediate Occupancy (IO) acceptance criteria according to ATC-40.The comparison of the pushover curve shows that the stiffness of frame is larger in (ESEE using BSI) compared to the (IBC2012 using ACI) design.This means that (ESEE using BSI) design has a greater capability to resist lateral load than the (IBC2012 using ACI) design. 116 pp. Englisch.…

- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 45,66
Envío por EUR 35,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponible
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The aim of this book is to evaluate seismic performance of existing low-to-mid-rise Reinforced Concrete (RC) frame buildings. The buildings, which consist of 4, 6, 8, and 10 stories, are designed according to British standard code (BSI) and American code (ACI).Pushover analysis has been performed according to FEMA-356 guidelines;the pushover analysis is used.The lateral load patterns for pushover analysis are selected as the Regulations for earthquake resistant design of building in Egypt, 1988; these regulations have been prepared by the Egyptian Society for Earthquake Engineering (ESEE) and International Building Code (IBC 2012). Results showed that the buildings designed considering the ESEE and IBC 2012 loads were found adequate. On the other hand, the building designed according to (ESEE using BSI) satisfies the Immediate Occupancy (IO) acceptance criteria according to ATC-40.The comparison of the pushover curve shows that the stiffness of frame is larger in (ESEE using BSI) compared to the (IBC2012 using ACI) design.This means that (ESEE using BSI) design has a greater capability to resist lateral load than the (IBC2012 using ACI) design.…

- Tapa blanda
- Impresión bajo demanda
Librería: moluna, Greven, Alemaniamoluna
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 34,25
Envío por EUR 48,99Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Abunama Mohammed Ahmed IsmaeilDr.Ismaeil Abunama is an Assistant Professor, Department of Civil Engineering, King Khalid University, KSA. On Leave from Sudan University of Science and Technology, Khartoum, Sudan.Dr.Ismaeil has studie.…

- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 39,90
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponible
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The aim of this book is to evaluate seismic performance of existing low-to-mid-rise Reinforced Concrete (RC) frame buildings. The buildings, which consist of 4, 6, 8, and 10 stories, are designed according to British standard code (BSI) and American code (ACI).Pushover analysis has been performed according to FEMA-356 guidelines;the pushover analysis is used.The lateral load patterns for pushover analysis are selected as the Regulations for earthquake resistant design of building in Egypt, 1988; these regulations have been prepared by the Egyptian Society for Earthquake Engineering (ESEE) and International Building Code (IBC 2012). Results showed that the buildings designed considering the ESEE and IBC 2012 loads were found adequate. On the other hand, the building designed according to (ESEE using BSI) satisfies the Immediate Occupancy (IO) acceptance criteria according to ATC-40.The comparison of the pushover curve shows that the stiffness of frame is larger in (ESEE using BSI) compared to the (IBC2012 using ACI) design.This means that (ESEE using BSI) design has a greater capability to resist lateral load than the (IBC2012 using ACI) design.Books on Demand GmbH, Überseering 33, 22297 Hamburg 116 pp. Englisch.…