Isbn: 9783330849228 - normal reverence range of complete blood count in sudanese population: the hematological findings in apparently healthy sudanese blood donors (6 resultados)

ISBN: 
Refinar con la Búsqueda avanzada

Filtrar la búsqueda

  • Libros (6)

  • Nuevo (6)

a

Intervalo de precios personalizado (EUR)

a

  • Idioma: Inglés

    Editorial: Noor Publishing, 2017

    3330849223 / 9783330849228

    • Tapa blanda

    Librería: Revaluation Books, Exeter, Reino UnidoRevaluation Books

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 64,97

    Envío por EUR 11,66 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 1 disponibles

    Paperback. Condición: Brand New. 80 pages. 8.66x5.91x0.19 inches. In Stock.

  • Idioma: Inglés

    Editorial: Noor Publishing, 2017

    3330849223 / 9783330849228

    • Tapa blanda

    Librería: moluna, Greven, Alemaniamoluna

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 31,27

    Envío por EUR 48,99 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    Kartoniert / Broschiert. Condición: New.

  • Idioma: Inglés

    Editorial: Noor Publishing Mai 2017, 2017

    3330849223 / 9783330849228

    • Tapa blanda
    • Impresión bajo demanda

    Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 35,90

    Envío por EUR 23,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 2 disponibles

    Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The aim of this study was to detect the haematological abnormalities in apparently healthy male donors to establish a safety for both donors and recipient and also to transfuse safe blood and blood products and to know the normal range of white blood cells, hemoglobin with red cell indices and platelets count. Venous blood samples were taken from 500 apparently healthy males donors and the haematological parameters were measured using an automated cell counter (sysmex KN21), haemoglobin concentration, red blood cells count, haemotocrit, mean corpuscular volume, mean corpuscular haemoglobin, mean corpuscular haemoglobin concentration, white blood counts, platelet counts, accompanied by peripheral blood films were assessed to detect any haematological abnormalities. For haemoglobin estimation copper sulphate method is routinely performed in Wad medanni blood bank. Although this method is not properly performed. In this study it was found that a considerable numbers of donors were anaemic, leucopenic, thrombocytopenic, few numbers with leucocytosis and thrombocytosis, high eosinophil percentage and lymphocyte percentage with reactive forms also detected. 80 pp. Englisch.…

  • Idioma: Inglés

    Editorial: Noor Publishing, 2017

    3330849223 / 9783330849228

    • Tapa blanda
    • Impresión bajo demanda

    Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 39,19

    Envío por EUR 35,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponibles

    Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The aim of this study was to detect the haematological abnormalities in apparently healthy male donors to establish a safety for both donors and recipient and also to transfuse safe blood and blood products and to know the normal range of white blood cells, hemoglobin with red cell indices and platelets count. Venous blood samples were taken from 500 apparently healthy males donors and the haematological parameters were measured using an automated cell counter (sysmex KN21), haemoglobin concentration, red blood cells count, haemotocrit, mean corpuscular volume, mean corpuscular haemoglobin, mean corpuscular haemoglobin concentration, white blood counts, platelet counts, accompanied by peripheral blood films were assessed to detect any haematological abnormalities. For haemoglobin estimation copper sulphate method is routinely performed in Wad medanni blood bank. Although this method is not properly performed. In this study it was found that a considerable numbers of donors were anaemic, leucopenic, thrombocytopenic, few numbers with leucocytosis and thrombocytosis, high eosinophil percentage and lymphocyte percentage with reactive forms also detected.…

  • Idioma: Inglés

    Editorial: Noor Publishing Mai 2017, 2017

    3330849223 / 9783330849228

    • Tapa blanda
    • Impresión bajo demanda

    Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 35,90

    Envío por EUR 60,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponibles

    Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The aim of this study was to detect the haematological abnormalities in apparently healthy male donors to establish a safety for both donors and recipient and also to transfuse safe blood and blood products and to know the normal range of white blood cells, hemoglobin with red cell indices and platelets count. Venous blood samples were taken from 500 apparently healthy males donors and the haematological parameters were measured using an automated cell counter (sysmex KN21), haemoglobin concentration, red blood cells count, haemotocrit, mean corpuscular volume, mean corpuscular haemoglobin, mean corpuscular haemoglobin concentration, white blood counts, platelet counts, accompanied by peripheral blood films were assessed to detect any haematological abnormalities. For haemoglobin estimation copper sulphate method is routinely performed in Wad medanni blood bank. Although this method is not properly performed. In this study it was found that a considerable numbers of donors were anaemic, leucopenic, thrombocytopenic, few numbers with leucocytosis and thrombocytosis, high eosinophil percentage and lymphocyte percentage with reactive forms also detected.Books on Demand GmbH, Überseering 33, 22297 Hamburg 80 pp. Englisch.…

  • Idioma: Inglés

    Editorial: Noor Publishing, 2017

    3330849223 / 9783330849228

    • Tapa blanda
    • Impresión bajo demanda

    Librería: preigu, Osnabrück, Alemaniapreigu

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 32,50

    Envío por EUR 70,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 5 disponibles

    Taschenbuch. Condición: Neu. Normal Reverence Range of Complete Blood Count in Sudanese population | The Hematological Findings in Apparently Healthy Sudanese Blood Donors | Asad Adam (u. a.) | Taschenbuch | Englisch | 2017 | Noor Publishing | EAN 9783330849228 | Verantwortliche Person für die EU: Noor Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu Print on Demand. …