9786204201696 - robust imc/imc-pid controller design: towards load frequency control of perturbed time-delayed power systems using model approximation de ganji, vasu; santosh kumar, bendalam (5 resultados)

- Tapa blanda
Librería: preigu, Osnabrück, Alemaniapreigu
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 36,25
Envío por EUR 70,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 5 disponibles
Taschenbuch. Condición: Neu. Robust Imc/imc-pid Controller Design | Towards Load Frequency Control of Perturbed Time-delayed Power Systems Using Model Approximation | Vasu Ganji (u. a.) | Taschenbuch | Englisch | 2021 | LAP LAMBERT Academic Publishing | EAN 9786204201696 | Verantwortliche Person für die EU: preigu GmbH & Co. KG,… Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, , AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 39,90
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Deregulated power system coupled with smart grid technology, for a network Load Frequency Control (LFC) strategy closed-loop feedback is through an open communication channel. The open communication link usually introduces time-dela…ys which degrade the performance of the closed-loop power system and exert to destabilization effect on the overall system. In this book an optimal IMC/IMC-PID control design is proposed for the single-area LFC system with time delay, the design is based on a process reduction control approach, simplifies the design, reduces the computational efforts and also helps in determining the lower order controller. An optimal IMC design methodology is proposed by minimizing ISE between the actual output and the reference input responses of the power system using the EDE algorithm. Finally, PID controller gains are acquired by the least-square model matching with the optimal IMC transfer function. The proposed IMC-PID controller design satisfies reference input tracking performance, robustness in disturbance rejection and improves the dynamic stability of the power system with/without communication delays. 88 pp. Englisch.

- Tapa blanda
- Impresión bajo demanda
Librería: moluna, Greven, , Alemaniamoluna
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 34,25
Envío por EUR 48,99Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Kartoniert / Broschiert. Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Ganji Vasu1) Dr G. Vasu working as an Associate Professor in Raghu Engineering College(A). He published 15-International Journal papers, 08-International and National Conference…s, 01-Book. 2) Mr B. Santosh Kumar working as an Assis.

- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 39,90
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Deregulated power system coupled with smart grid technology, for a network Load Frequency Control (LFC) strategy closed-loop feedback is through an open communication channel. The open communication link usually introduces time-delays w…hich degrade the performance of the closed-loop power system and exert to destabilization effect on the overall system. In this book an optimal IMC/IMC-PID control design is proposed for the single-area LFC system with time delay, the design is based on a process reduction control approach, simplifies the design, reduces the computational efforts and also helps in determining the lower order controller. An optimal IMC design methodology is proposed by minimizing ISE between the actual output and the reference input responses of the power system using the EDE algorithm. Finally, PID controller gains are acquired by the least-square model matching with the optimal IMC transfer function. The proposed IMC-PID controller design satisfies reference input tracking performance, robustness in disturbance rejection and improves the dynamic stability of the power system with/without communication delays.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 88 pp. Englisch.

- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 40,89
Envío por EUR 60,75Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Deregulated power system coupled with smart grid technology, for a network Load Frequency Control (LFC) strategy closed-loop feedback is through an open communication channel. The open communication link usually introduces time-delays wh…ich degrade the performance of the closed-loop power system and exert to destabilization effect on the overall system. In this book an optimal IMC/IMC-PID control design is proposed for the single-area LFC system with time delay, the design is based on a process reduction control approach, simplifies the design, reduces the computational efforts and also helps in determining the lower order controller. An optimal IMC design methodology is proposed by minimizing ISE between the actual output and the reference input responses of the power system using the EDE algorithm. Finally, PID controller gains are acquired by the least-square model matching with the optimal IMC transfer function. The proposed IMC-PID controller design satisfies reference input tracking performance, robustness in disturbance rejection and improves the dynamic stability of the power system with/without communication delays.