ISBN: 9786203853612 - protection in expanded power system with fault current limiter and pll (4 resultados)

ISBN: 
Refinar con la Búsqueda avanzada

Filtrar la búsqueda

  • Libros (4)

  • Nuevo (4)

a

Intervalo de precios personalizado (EUR)

a

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2021

    6203853615 / 9786203853612

    • Tapa blanda

    Librería: moluna, Greven, Alemaniamoluna

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 34,25

    Envío por EUR 48,99 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    Condición: New.

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing Apr 2021, 2021

    6203853615 / 9786203853612

    • Tapa blanda
    • Impresión bajo demanda

    Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 39,90

    Envío por EUR 23,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 2 disponibles

    Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In this book, a new method is proposed that can be used to discriminate faults from switching transients. The method is mainly intended for use in systems where fast fault recognition and rapid fault clearing before the first peak of the fault current are required. An industrial system, in which high short-circuit power is most wanted but in which high short-circuit currents cannot be tolerated is an example of such a system. A phase-locked loop (PLL) is used to perform the discrimination. Computer simulations have been performed and it has been demonstrated that the output of the PLL is completely dissimilar for a fault compared to a switching transient. This difference can be used for discrimination between a fault and a switching transient. 84 pp. Englisch.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2021

    6203853615 / 9786203853612

    • Tapa blanda
    • Impresión bajo demanda

    Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 45,66

    Envío por EUR 35,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In this book, a new method is proposed that can be used to discriminate faults from switching transients. The method is mainly intended for use in systems where fast fault recognition and rapid fault clearing before the first peak of the fault current are required. An industrial system, in which high short-circuit power is most wanted but in which high short-circuit currents cannot be tolerated is an example of such a system. A phase-locked loop (PLL) is used to perform the discrimination. Computer simulations have been performed and it has been demonstrated that the output of the PLL is completely dissimilar for a fault compared to a switching transient. This difference can be used for discrimination between a fault and a switching transient.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing Apr 2021, 2021

    6203853615 / 9786203853612

    • Tapa blanda
    • Impresión bajo demanda

    Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 39,90

    Envío por EUR 60,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In this book, a new method is proposed that can be used to discriminate faults from switching transients. The method is mainly intended for use in systems where fast fault recognition and rapid fault clearing before the first peak of the fault current are required. An industrial system, in which high short-circuit power is most wanted but in which high short-circuit currents cannot be tolerated is an example of such a system. A phase-locked loop (PLL) is used to perform the discrimination. Computer simulations have been performed and it has been demonstrated that the output of the PLL is completely dissimilar for a fault compared to a switching transient. This difference can be used for discrimination between a fault and a switching transient.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 84 pp. Englisch.…