9786200326331 - response spectrum analysis: response spectrum analysis in flat slab multistorey building for earthquake zone iv de giri, markanday; jamle, sagar; meshram, kundan (6 resultados)

- Tapa blanda
Librería: preigu, Osnabrück, Alemaniapreigu
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 61,05
Envío por EUR 70,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 5 disponibles
Taschenbuch. Condición: Neu. Response Spectrum Analysis | Response Spectrum Analysis in Flat Slab Multistorey Building for Earthquake Zone IV | Markanday Giri (u. a.) | Taschenbuch | 176 S. | Englisch | 2020 | LAP LAMBERT Academic Publishing | EAN 9786200326331 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengerich…er Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

- Tapa blanda
Librería: Mispah books, Redhill, SURRE, Reino UnidoMispah books
Contactar con el vendedorVendedor de 4 estrellasCondición: Nuevo
EUR 200,70
Envío por EUR 29,17Se envía de Reino Unido a Estados Unidos de AmericaCantidad disponible: 1 disponibles
paperback. Condición: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 71,90
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The necessity of large head room are now the essential point of view for any architecture and for that, the only way to solve this as per structural point of view is to be provide flat slab. The elimination of beam could show the dr…astic effect in different component of the structure. It has been examine from various findings that the stresses generated in the flat slab analysis, its intensity should lessen in order to provide stability to the structure. For this, four cases have been taken viz., simple flat slab providing shear wall at lift area, simple flat slab providing shear wall at lift area and at maximum stress location, flat slab with drop providing shear wall at lift area and flat slab with drop providing shear wall at lift area and at maximum stress location on G+11 Multistoried residential building located at Seismic Zone IV. Using response spectrum method with the help of analysis and design tool STAAD Pro V8i, to evaluate analysis parameters such as Nodal Displacement, Shear forces in column, Compressive and tensile stresses, storey drift, von mis stress along with principle stress values. The prime case is obtained in this work is building case B2. 176 pp. Englisch.

- Tapa blanda
- Impresión bajo demanda
Librería: moluna, Greven, Alemaniamoluna
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 58,12
Envío por EUR 48,99Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Giri MarkandayI am Dr. Kundan Meshram, Associate Professor and Head, Department of Civil Engineering, Oriental University, Indore(M.P.)The necessity of large head room are now the essential point of vie…w for any architecture and .

- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 71,90
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The necessity of large head room are now the essential point of view for any architecture and for that, the only way to solve this as per structural point of view is to be provide flat slab. The elimination of beam could show the drasti…c effect in different component of the structure. It has been examine from various findings that the stresses generated in the flat slab analysis, its intensity should lessen in order to provide stability to the structure. For this, four cases have been taken viz., simple flat slab providing shear wall at lift area, simple flat slab providing shear wall at lift area and at maximum stress location, flat slab with drop providing shear wall at lift area and flat slab with drop providing shear wall at lift area and at maximum stress location on G+11 Multistoried residential building located at Seismic Zone IV. Using response spectrum method with the help of analysis and design tool STAAD Pro V8i, to evaluate analysis parameters such as Nodal Displacement, Shear forces in column, Compressive and tensile stresses, storey drift, von mis stress along with principle stress values. The prime case is obtained in this work is building case B2.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 176 pp. Englisch.

- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 72,76
Envío por EUR 61,40Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The necessity of large head room are now the essential point of view for any architecture and for that, the only way to solve this as per structural point of view is to be provide flat slab. The elimination of beam could show the drastic… effect in different component of the structure. It has been examine from various findings that the stresses generated in the flat slab analysis, its intensity should lessen in order to provide stability to the structure. For this, four cases have been taken viz., simple flat slab providing shear wall at lift area, simple flat slab providing shear wall at lift area and at maximum stress location, flat slab with drop providing shear wall at lift area and flat slab with drop providing shear wall at lift area and at maximum stress location on G+11 Multistoried residential building located at Seismic Zone IV. Using response spectrum method with the help of analysis and design tool STAAD Pro V8i, to evaluate analysis parameters such as Nodal Displacement, Shear forces in column, Compressive and tensile stresses, storey drift, von mis stress along with principle stress values. The prime case is obtained in this work is building case B2.