Idioma: Inglés
Publicado por LAP LAMBERT Academic Publishing Sep 2019, 2019
ISBN 10: 6200225087 ISBN 13: 9786200225085
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
EUR 39,90
Cantidad disponible: 2 disponibles
Añadir al carritoTaschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Induction Generator wind turbine system uses a fixed speed wind turbine (FSWT) system. Due to highly depend on reactive power, it bears highly to achieve new wind grid code requirements. Induction generator requires high reactive power during network disturbances. Nowadays FACTS (flexible AC transmission system) devices are available in the market for compensation of reactive power of FSWT induction generator during network disturbances. The use of FACTS devices in wind system increase the total budget. So, we have to concentrate on new innovative kind of topology which is cost-effective as well as gives the exact solution to the problem. The new idea is to locate the PMSG near to FSWT induction generator & connect via underground cable at PCC. Variable speed wind turbine (VSWT) - PMSG has the ability to fulfill the requirements of reactive power during network disturbances. So, when there is a fault on the network reactive power requirement of an induction generator is fulfill by VSWT-PMSG to meet wind grid code requirement. Low voltage ride-through (LVRT) or fault ride through the characteristic of FSWT induction generator is analyze using Indian grid code. 64 pp. Englisch.
Idioma: Inglés
Publicado por LAP LAMBERT Academic Publishing, 2019
ISBN 10: 6200225087 ISBN 13: 9786200225085
Librería: moluna, Greven, Alemania
EUR 34,25
Cantidad disponible: Más de 20 disponibles
Añadir al carritoCondición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Patel Prof. AbhishekAbhishek Patel has received B.E. degree in Electrical Engineering from VNSGU, India in 2011. He had done his masters from G. H. Patel College of Engineering and Technology, Gujarat, India in 2015. He has vast expe.
Idioma: Inglés
Publicado por LAP LAMBERT Academic Publishing Sep 2019, 2019
ISBN 10: 6200225087 ISBN 13: 9786200225085
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
EUR 39,90
Cantidad disponible: 1 disponibles
Añadir al carritoTaschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Induction Generator wind turbine system uses a fixed speed wind turbine (FSWT) system. Due to highly depend on reactive power, it bears highly to achieve new wind grid code requirements. Induction generator requires high reactive power during network disturbances. Nowadays FACTS (flexible AC transmission system) devices are available in the market for compensation of reactive power of FSWT induction generator during network disturbances. The use of FACTS devices in wind system increase the total budget. So, we have to concentrate on new innovative kind of topology which is cost-effective as well as gives the exact solution to the problem. The new idea is to locate the PMSG near to FSWT induction generator & connect via underground cable at PCC. Variable speed wind turbine (VSWT) - PMSG has the ability to fulfill the requirements of reactive power during network disturbances. So, when there is a fault on the network reactive power requirement of an induction generator is fulfill by VSWT-PMSG to meet wind grid code requirement. Low voltage ride-through (LVRT) or fault ride through the characteristic of FSWT induction generator is analyze using Indian grid code.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 64 pp. Englisch.
Idioma: Inglés
Publicado por LAP LAMBERT Academic Publishing, 2019
ISBN 10: 6200225087 ISBN 13: 9786200225085
Librería: AHA-BUCH GmbH, Einbeck, Alemania
EUR 40,89
Cantidad disponible: 1 disponibles
Añadir al carritoTaschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Induction Generator wind turbine system uses a fixed speed wind turbine (FSWT) system. Due to highly depend on reactive power, it bears highly to achieve new wind grid code requirements. Induction generator requires high reactive power during network disturbances. Nowadays FACTS (flexible AC transmission system) devices are available in the market for compensation of reactive power of FSWT induction generator during network disturbances. The use of FACTS devices in wind system increase the total budget. So, we have to concentrate on new innovative kind of topology which is cost-effective as well as gives the exact solution to the problem. The new idea is to locate the PMSG near to FSWT induction generator & connect via underground cable at PCC. Variable speed wind turbine (VSWT) - PMSG has the ability to fulfill the requirements of reactive power during network disturbances. So, when there is a fault on the network reactive power requirement of an induction generator is fulfill by VSWT-PMSG to meet wind grid code requirement. Low voltage ride-through (LVRT) or fault ride through the characteristic of FSWT induction generator is analyze using Indian grid code.
Idioma: Inglés
Publicado por LAP LAMBERT Academic Publishing, 2019
ISBN 10: 6200225087 ISBN 13: 9786200225085
Librería: preigu, Osnabrück, Alemania
EUR 35,60
Cantidad disponible: 5 disponibles
Añadir al carritoTaschenbuch. Condición: Neu. LVRT Augmentation of fixed speed wind turbine using VSWT-PMSG | Abhishek Patel (u. a.) | Taschenbuch | 64 S. | Englisch | 2019 | LAP LAMBERT Academic Publishing | EAN 9786200225085 | Verantwortliche Person für die EU: LAP Lambert Academic Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu Print on Demand.