Isbn: 9786139454754 - simultaneous estimation of cefixime and linezolid: by hplc method (8 resultados)

ISBN: 
Refinar con la Búsqueda avanzada

Filtrar la búsqueda

  • Libros (8)

a

Intervalo de precios personalizado (EUR)

a

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2019

    6139454751 / 9786139454754

    • Tapa blanda

    Librería: preigu, Osnabrück, Alemaniapreigu

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 36,35

    Envío por EUR 70,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 5 disponibles

    Taschenbuch. Condición: Neu. Simultaneous Estimation of Cefixime and Linezolid | By HPLC Method | Imran Chaki (u. a.) | Taschenbuch | 88 S. | Englisch | 2019 | LAP LAMBERT Academic Publishing | EAN 9786139454754 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. …

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2019

    6139454751 / 9786139454754

    • Tapa blanda

    Librería: Buchpark, Trebbin, AlemaniaBuchpark

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Usado - Excelente

    EUR 29,28

    Envío por EUR 105,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Condición: Sehr gut. Zustand: Sehr gut | Sprache: Englisch | Produktart: Bücher | Development and validation of simple, precise, accurate, economical and sensitive HPLC assay method for the estimation of Cefixime and Linezolid in tablet dosage form. A chromatographic separation was achieved with a Hypersil BDS C18 (250mm,4.6mm ,5µm) analytical column. A Mixture of Phosphate Buffer (3.0 pH): methanol (40:60, v/v) was used as the mobile phase, at a flow rate of 1.0 ml/min and detector wavelength at 277 nm. The retention time of Cefixime and linezolid was found to be 3.76 and 6.55 min respectively. Theoretical plates was 6896 and 4626 respectively and Tailing factor was 1.32 and 1.28. The linear ranges was 5-15 for cefixime and 15-45 ¿g/ml for linezolid, and the correlation coefficient was 0.999 for both drugs. The relative standard deviation was found to be less than 2%. A simple, precise, accurate, economical and sensitive HPLC assay method have been developed and validated for the estimation of Cefixime and linezolid in tablet dosage form. All method validation parameters lie within its acceptance crieteria as per ICH Q2(R1) guideline.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2019

    6139454751 / 9786139454754

    • Tapa blanda

    Librería: Buchpark, Trebbin, AlemaniaBuchpark

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Usado

    EUR 30,16

    Envío por EUR 105,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 2 disponibles

    Condición: Hervorragend. Zustand: Hervorragend | Sprache: Englisch | Produktart: Bücher | Development and validation of simple, precise, accurate, economical and sensitive HPLC assay method for the estimation of Cefixime and Linezolid in tablet dosage form. A chromatographic separation was achieved with a Hypersil BDS C18 (250mm,4.6mm ,5µm) analytical column. A Mixture of Phosphate Buffer (3.0 pH): methanol (40:60, v/v) was used as the mobile phase, at a flow rate of 1.0 ml/min and detector wavelength at 277 nm. The retention time of Cefixime and linezolid was found to be 3.76 and 6.55 min respectively. Theoretical plates was 6896 and 4626 respectively and Tailing factor was 1.32 and 1.28. The linear ranges was 5-15 for cefixime and 15-45 ¿g/ml for linezolid, and the correlation coefficient was 0.999 for both drugs. The relative standard deviation was found to be less than 2%. A simple, precise, accurate, economical and sensitive HPLC assay method have been developed and validated for the estimation of Cefixime and linezolid in tablet dosage form. All method validation parameters lie within its acceptance crieteria as per ICH Q2(R1) guideline.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2019

    6139454751 / 9786139454754

    • Tapa blanda

    Librería: Mispah books, Redhill, SURRE, Reino UnidoMispah books

    Vendedor de 4 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 142,60

    Envío por EUR 29,33 
    Se envía de Reino Unido a Estados Unidos de America

    Cantidad disponible: 1 disponible

    paperback. Condición: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing Feb 2019, 2019

    6139454751 / 9786139454754

    • Tapa blanda
    • Impresión bajo demanda

    Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 39,90

    Envío por EUR 23,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Development and validation of simple, precise, accurate, economical and sensitive HPLC assay method for the estimation of Cefixime and Linezolid in tablet dosage form. A chromatographic separation was achieved with a Hypersil BDS C18 (250mm,4.6mm ,5µm) analytical column. A Mixture of Phosphate Buffer (3.0 pH): methanol (40:60, v/v) was used as the mobile phase, at a flow rate of 1.0 ml/min and detector wavelength at 277 nm. The retention time of Cefixime and linezolid was found to be 3.76 and 6.55 min respectively. Theoretical plates was 6896 and 4626 respectively and Tailing factor was 1.32 and 1.28. The linear ranges was 5-15 for cefixime and 15-45 mig/ml for linezolid, and the correlation coefficient was 0.999 for both drugs. The relative standard deviation was found to be less than 2%. A simple, precise, accurate, economical and sensitive HPLC assay method have been developed and validated for the estimation of Cefixime and linezolid in tablet dosage form. All method validation parameters lie within its acceptance crieteria as per ICH Q2(R1) guideline. 88 pp. Englisch.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2019

    6139454751 / 9786139454754

    • Tapa blanda
    • Impresión bajo demanda

    Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 40,38

    Envío por EUR 35,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Development and validation of simple, precise, accurate, economical and sensitive HPLC assay method for the estimation of Cefixime and Linezolid in tablet dosage form. A chromatographic separation was achieved with a Hypersil BDS C18 (250mm,4.6mm ,5µm) analytical column. A Mixture of Phosphate Buffer (3.0 pH): methanol (40:60, v/v) was used as the mobile phase, at a flow rate of 1.0 ml/min and detector wavelength at 277 nm. The retention time of Cefixime and linezolid was found to be 3.76 and 6.55 min respectively. Theoretical plates was 6896 and 4626 respectively and Tailing factor was 1.32 and 1.28. The linear ranges was 5-15 for cefixime and 15-45 mig/ml for linezolid, and the correlation coefficient was 0.999 for both drugs. The relative standard deviation was found to be less than 2%. A simple, precise, accurate, economical and sensitive HPLC assay method have been developed and validated for the estimation of Cefixime and linezolid in tablet dosage form. All method validation parameters lie within its acceptance crieteria as per ICH Q2(R1) guideline.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2019

    6139454751 / 9786139454754

    • Tapa blanda
    • Impresión bajo demanda

    Librería: moluna, Greven, Alemaniamoluna

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 34,25

    Envío por EUR 48,99 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: Más de 20 disponibles

    Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Chaki ImranImran A. Chaki, Master of Pharmacy, Pharmaceutical Quality Assurance from Gujarat Technological University. Research Associate at Quantys Clinical Private Limited in Quality Assurance DepartmentDevelopment and validati.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing Feb 2019, 2019

    6139454751 / 9786139454754

    • Tapa blanda
    • Impresión bajo demanda

    Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 39,90

    Envío por EUR 60,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Development and validation of simple, precise, accurate, economical and sensitive HPLC assay method for the estimation of Cefixime and Linezolid in tablet dosage form. A chromatographic separation was achieved with a Hypersil BDS C18 (250mm,4.6mm ,5µm) analytical column. A Mixture of Phosphate Buffer (3.0 pH): methanol (40:60, v/v) was used as the mobile phase, at a flow rate of 1.0 ml/min and detector wavelength at 277 nm. The retention time of Cefixime and linezolid was found to be 3.76 and 6.55 min respectively. Theoretical plates was 6896 and 4626 respectively and Tailing factor was 1.32 and 1.28. The linear ranges was 5-15 for cefixime and 15-45 ¿g/ml for linezolid, and the correlation coefficient was 0.999 for both drugs. The relative standard deviation was found to be less than 2%. A simple, precise, accurate, economical and sensitive HPLC assay method have been developed and validated for the estimation of Cefixime and linezolid in tablet dosage form. All method validation parameters lie within its acceptance crieteria as per ICH Q2(R1) guideline.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 88 pp. Englisch.…