9786139454754 - simultaneous estimation of cefixime and linezolid: by hplc method de chaki, imran; patel, pratik; pujara, naisarg (8 resultados)

- Tapa blanda
Librería: preigu, Osnabrück, Alemaniapreigu
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 35,60
Envío por EUR 70,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 5 disponibles
Taschenbuch. Condición: Neu. Simultaneous Estimation of Cefixime and Linezolid | By HPLC Method | Imran Chaki (u. a.) | Taschenbuch | 88 S. | Englisch | 2019 | LAP LAMBERT Academic Publishing | EAN 9786139454754 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[do…t]de | Anbieter: preigu.

- Tapa blanda
Librería: Buchpark, Trebbin, AlemaniaBuchpark
Contactar con el vendedorVendedor de 5 estrellasCondición: Usado - Excelente
EUR 29,28
Envío por EUR 105,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Condición: Sehr gut. Zustand: Sehr gut | Sprache: Englisch | Produktart: Bücher | Development and validation of simple, precise, accurate, economical and sensitive HPLC assay method for the estimation of Cefixime and Linezolid in tablet dosage form. A chromatographic separation was achieved with a Hypersil BDS C18 (250mm,4.6mm ,…5µm) analytical column. A Mixture of Phosphate Buffer (3.0 pH): methanol (40:60, v/v) was used as the mobile phase, at a flow rate of 1.0 ml/min and detector wavelength at 277 nm. The retention time of Cefixime and linezolid was found to be 3.76 and 6.55 min respectively. Theoretical plates was 6896 and 4626 respectively and Tailing factor was 1.32 and 1.28. The linear ranges was 5-15 for cefixime and 15-45 ¿g/ml for linezolid, and the correlation coefficient was 0.999 for both drugs. The relative standard deviation was found to be less than 2%. A simple, precise, accurate, economical and sensitive HPLC assay method have been developed and validated for the estimation of Cefixime and linezolid in tablet dosage form. All method validation parameters lie within its acceptance crieteria as per ICH Q2(R1) guideline.

- Tapa blanda
Librería: Buchpark, Trebbin, AlemaniaBuchpark
Contactar con el vendedorVendedor de 5 estrellasCondición: Usado
EUR 30,16
Envío por EUR 105,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Condición: Hervorragend. Zustand: Hervorragend | Sprache: Englisch | Produktart: Bücher | Development and validation of simple, precise, accurate, economical and sensitive HPLC assay method for the estimation of Cefixime and Linezolid in tablet dosage form. A chromatographic separation was achieved with a Hypersil BDS C18 (250mm…,4.6mm ,5µm) analytical column. A Mixture of Phosphate Buffer (3.0 pH): methanol (40:60, v/v) was used as the mobile phase, at a flow rate of 1.0 ml/min and detector wavelength at 277 nm. The retention time of Cefixime and linezolid was found to be 3.76 and 6.55 min respectively. Theoretical plates was 6896 and 4626 respectively and Tailing factor was 1.32 and 1.28. The linear ranges was 5-15 for cefixime and 15-45 ¿g/ml for linezolid, and the correlation coefficient was 0.999 for both drugs. The relative standard deviation was found to be less than 2%. A simple, precise, accurate, economical and sensitive HPLC assay method have been developed and validated for the estimation of Cefixime and linezolid in tablet dosage form. All method validation parameters lie within its acceptance crieteria as per ICH Q2(R1) guideline.

- Tapa blanda
Librería: Mispah books, Redhill, SURRE, Reino UnidoMispah books
Contactar con el vendedorVendedor de 4 estrellasCondición: Nuevo
EUR 141,10
Envío por EUR 29,02Se envía de Reino Unido a Estados Unidos de AmericaCantidad disponible: 1 disponibles
paperback. Condición: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 39,90
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Development and validation of simple, precise, accurate, economical and sensitive HPLC assay method for the estimation of Cefixime and Linezolid in tablet dosage form. A chromatographic separation was achieved with a Hypersil BDS C1…8 (250mm,4.6mm ,5µm) analytical column. A Mixture of Phosphate Buffer (3.0 pH): methanol (40:60, v/v) was used as the mobile phase, at a flow rate of 1.0 ml/min and detector wavelength at 277 nm. The retention time of Cefixime and linezolid was found to be 3.76 and 6.55 min respectively. Theoretical plates was 6896 and 4626 respectively and Tailing factor was 1.32 and 1.28. The linear ranges was 5-15 for cefixime and 15-45 mig/ml for linezolid, and the correlation coefficient was 0.999 for both drugs. The relative standard deviation was found to be less than 2%. A simple, precise, accurate, economical and sensitive HPLC assay method have been developed and validated for the estimation of Cefixime and linezolid in tablet dosage form. All method validation parameters lie within its acceptance crieteria as per ICH Q2(R1) guideline. 88 pp. Englisch.

- Tapa blanda
- Impresión bajo demanda
Librería: moluna, Greven, Alemaniamoluna
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 34,25
Envío por EUR 48,99Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Chaki ImranImran A. Chaki, Master of Pharmacy, Pharmaceutical Quality Assurance from Gujarat Technological University. Research Associate at Quantys Clinical Private Limited in Quality Assurance Departm…entDevelopment and validati.

- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 39,90
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Development and validation of simple, precise, accurate, economical and sensitive HPLC assay method for the estimation of Cefixime and Linezolid in tablet dosage form. A chromatographic separation was achieved with a Hypersil BDS C18 (2…50mm,4.6mm ,5µm) analytical column. A Mixture of Phosphate Buffer (3.0 pH): methanol (40:60, v/v) was used as the mobile phase, at a flow rate of 1.0 ml/min and detector wavelength at 277 nm. The retention time of Cefixime and linezolid was found to be 3.76 and 6.55 min respectively. Theoretical plates was 6896 and 4626 respectively and Tailing factor was 1.32 and 1.28. The linear ranges was 5-15 for cefixime and 15-45 ¿g/ml for linezolid, and the correlation coefficient was 0.999 for both drugs. The relative standard deviation was found to be less than 2%. A simple, precise, accurate, economical and sensitive HPLC assay method have been developed and validated for the estimation of Cefixime and linezolid in tablet dosage form. All method validation parameters lie within its acceptance crieteria as per ICH Q2(R1) guideline.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 88 pp. Englisch.

- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 40,89
Envío por EUR 60,75Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Development and validation of simple, precise, accurate, economical and sensitive HPLC assay method for the estimation of Cefixime and Linezolid in tablet dosage form. A chromatographic separation was achieved with a Hypersil BDS C18 (25…0mm,4.6mm ,5µm) analytical column. A Mixture of Phosphate Buffer (3.0 pH): methanol (40:60, v/v) was used as the mobile phase, at a flow rate of 1.0 ml/min and detector wavelength at 277 nm. The retention time of Cefixime and linezolid was found to be 3.76 and 6.55 min respectively. Theoretical plates was 6896 and 4626 respectively and Tailing factor was 1.32 and 1.28. The linear ranges was 5-15 for cefixime and 15-45 mig/ml for linezolid, and the correlation coefficient was 0.999 for both drugs. The relative standard deviation was found to be less than 2%. A simple, precise, accurate, economical and sensitive HPLC assay method have been developed and validated for the estimation of Cefixime and linezolid in tablet dosage form. All method validation parameters lie within its acceptance crieteria as per ICH Q2(R1) guideline.