9783848443123 - seismic risk assessment of buildings: case study abbottabad city (pakistan) de shahzada, khan; naeem khan, akhtar; javed, muhammad (6 resultados)

- Tapa blanda
Librería: preigu, Osnabrück, Alemaniapreigu
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 66,50
Envío por EUR 70,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 5 disponibles
Taschenbuch. Condición: Neu. Seismic Risk Assessment of Buildings | Case Study Abbottabad City (Pakistan) | Khan Shahzada (u. a.) | Taschenbuch | 408 S. | Englisch | 2012 | LAP LAMBERT Academic Publishing | EAN 9783848443123 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail…[at]preigu[dot]de | Anbieter: preigu.

- Tapa blanda
Librería: Mispah books, Redhill, SURRE, Reino UnidoMispah books
Contactar con el vendedorVendedor de 4 estrellasCondición: Usado - Como Nuevo
EUR 175,03
Envío por EUR 29,10Se envía de Reino Unido a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Paperback. Condición: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 79,00
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book covers the seismic risk assessment of existing buildings based on hazard and vulnerability assessment. Hazard maps have been developed and vulnerability assessment of buildings was made by collecting inventory data and exp…erimental study of typical existing buildings. Fragility curves for different types of buildings including single and double stories unreinforced brick masonry and concrete block masonry buildings, single, double and three stories confined brick masonry buildings, and double stories reinforced concrete buildings by using advanced capacity spectrum method (ACSM). Seismic risk has been established for all these buildings from hazard maps and corresponding fragility curves. The seismic risk determined from the hazard maps and fragility curves has been compared with the seismic risk calculated by using MAEviz software developed by Mid America Earthquake (MAE) Centre. It was found that Seismic risk for collapse prevention level is highest for unreinforced concrete block masonry buildings and similarly the seismic risk for confined brick masonry buildings is least. It was also concluded that the seismic risk for reinforced concrete buildings is minimum. 408 pp. Englisch.

- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 81,22
Envío por EUR 30,50Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book covers the seismic risk assessment of existing buildings based on hazard and vulnerability assessment. Hazard maps have been developed and vulnerability assessment of buildings was made by collecting inventory data and experime…ntal study of typical existing buildings. Fragility curves for different types of buildings including single and double stories unreinforced brick masonry and concrete block masonry buildings, single, double and three stories confined brick masonry buildings, and double stories reinforced concrete buildings by using advanced capacity spectrum method (ACSM). Seismic risk has been established for all these buildings from hazard maps and corresponding fragility curves. The seismic risk determined from the hazard maps and fragility curves has been compared with the seismic risk calculated by using MAEviz software developed by Mid America Earthquake (MAE) Centre. It was found that Seismic risk for collapse prevention level is highest for unreinforced concrete block masonry buildings and similarly the seismic risk for confined brick masonry buildings is least. It was also concluded that the seismic risk for reinforced concrete buildings is minimum.

- Tapa blanda
- Impresión bajo demanda
Librería: moluna, Greven, Alemaniamoluna
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 63,42
Envío por EUR 48,99Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Shahzada KhanDr. Khan Shahzada completed his BSc study in Civil Engineering from University of Engineering and Technology Peshawar in 2003.He completed his MSc in Earthquake Engineering from Japan in 20…07 and his PhD from UET Peshawa.

- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 79,00
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book covers the seismic risk assessment of existing buildings based on hazard and vulnerability assessment. Hazard maps have been developed and vulnerability assessment of buildings was made by collecting inventory data and experim…ental study of typical existing buildings. Fragility curves for different types of buildings including single and double stories unreinforced brick masonry and concrete block masonry buildings, single, double and three stories confined brick masonry buildings, and double stories reinforced concrete buildings by using advanced capacity spectrum method (ACSM). Seismic risk has been established for all these buildings from hazard maps and corresponding fragility curves. The seismic risk determined from the hazard maps and fragility curves has been compared with the seismic risk calculated by using MAEviz software developed by Mid America Earthquake (MAE) Centre. It was found that Seismic risk for collapse prevention level is highest for unreinforced concrete block masonry buildings and similarly the seismic risk for confined brick masonry buildings is least. It was also concluded that the seismic risk for reinforced concrete buildings is minimum.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 408 pp. Englisch.