Idioma: Inglés
Publicado por LAP LAMBERT Academic Publishing, 2011
ISBN 10: 3845429593 ISBN 13: 9783845429595
Librería: preigu, Osnabrück, Alemania
EUR 43,30
Cantidad disponible: 5 disponibles
Añadir al carritoTaschenbuch. Condición: Neu. Transient Stability Analysis | A Novel Method for Transient Stability Analysis of a Multimachine Power System | Md. Abdus Salam | Taschenbuch | 80 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783845429595 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.
Idioma: Inglés
Publicado por LAP LAMBERT Academic Publishing, 2011
ISBN 10: 3845429593 ISBN 13: 9783845429595
Librería: Mispah books, Redhill, SURRE, Reino Unido
EUR 119,96
Cantidad disponible: 1 disponibles
Añadir al carritoPaperback. Condición: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book.
Idioma: Inglés
Publicado por LAP LAMBERT Academic Publishing Sep 2011, 2011
ISBN 10: 3845429593 ISBN 13: 9783845429595
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
EUR 49,00
Cantidad disponible: 2 disponibles
Añadir al carritoTaschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book is written based on my M. Sc. Engineering thesis. The method uses a set of closed loop transfer functions, one for each synchronous machine and derived by taking Laplace transformation of the machine s nonlinear swing equation in a tricky way. The transfer function directly takes into account the time of fault clearing and the changes in the maximum electrical power output of the machine due to changes in the prefault network topology during and after clearing the fault. The earliest possible location of the root of the characteristic equation (the denominator of the transfer function equated to zero) is searched in the s-plane for each machine starting from a real value of s which is the same for all the machines. The narrowest possible range i. e the lower and upper limits of the location is found by observing sign changes of the transfer function expression evaluated at several step values of s obtained by increasing starting value by a suitable chosen increment. 80 pp. Englisch.
Idioma: Inglés
Publicado por LAP LAMBERT Academic Publishing, 2011
ISBN 10: 3845429593 ISBN 13: 9783845429595
Librería: moluna, Greven, Alemania
EUR 41,05
Cantidad disponible: Más de 20 disponibles
Añadir al carritoCondición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Salam Md. AbdusHe obtained his B. Sc., M. Sc. and PhD all in Electrical Engineering from CUET,Chittagong, BUET, Dhaka and UTM, Malaysia respectively. He was a faculty member at CUET from 1994 to 2001. He worked as an Assistant Profes.
Idioma: Inglés
Publicado por LAP LAMBERT Academic Publishing Sep 2011, 2011
ISBN 10: 3845429593 ISBN 13: 9783845429595
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
EUR 49,00
Cantidad disponible: 1 disponibles
Añadir al carritoTaschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book is written based on my M. Sc. Engineering thesis. The method uses a set of closed loop transfer functions, one for each synchronous machine and derived by taking Laplace transformation of the machine¿s nonlinear swing equation in a tricky way. The transfer function directly takes into account the time of fault clearing and the changes in the maximum electrical power output of the machine due to changes in the prefault network topology during and after clearing the fault. The earliest possible location of the root of the characteristic equation (the denominator of the transfer function equated to zero) is searched in the s-plane for each machine starting from a real value of s which is the same for all the machines. The narrowest possible range i. e the lower and upper limits of the location is found by observing sign changes of the transfer function expression evaluated at several step values of s obtained by increasing starting value by a suitable chosen increment.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 80 pp. Englisch.
Idioma: Inglés
Publicado por LAP LAMBERT Academic Publishing, 2011
ISBN 10: 3845429593 ISBN 13: 9783845429595
Librería: AHA-BUCH GmbH, Einbeck, Alemania
EUR 49,59
Cantidad disponible: 1 disponibles
Añadir al carritoTaschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book is written based on my M. Sc. Engineering thesis. The method uses a set of closed loop transfer functions, one for each synchronous machine and derived by taking Laplace transformation of the machine s nonlinear swing equation in a tricky way. The transfer function directly takes into account the time of fault clearing and the changes in the maximum electrical power output of the machine due to changes in the prefault network topology during and after clearing the fault. The earliest possible location of the root of the characteristic equation (the denominator of the transfer function equated to zero) is searched in the s-plane for each machine starting from a real value of s which is the same for all the machines. The narrowest possible range i. e the lower and upper limits of the location is found by observing sign changes of the transfer function expression evaluated at several step values of s obtained by increasing starting value by a suitable chosen increment.