Isbn: 9783838152301 - finite element simulation techniques for fluid structure interaction: applications to bio-engineering and optimization (5 resultados)

Idioma: Inglés
Editorial: Südwestdeutscher Verlag für Hochschulschriften, 2016
- Tapa blanda
Librería: preigu, Osnabrück, Alemaniapreigu
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 40,20
Envío por EUR 70,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 5 disponibles
Taschenbuch. Condición: Neu. Finite element simulation techniques for fluid structure interaction | Applications to bio-engineering and optimization | Mudassar Razzaq | Taschenbuch | 152 S. | Englisch | 2016 | Südwestdeutscher Verlag für Hochschulschriften | EAN 9783838152301 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

Idioma: Inglés
Editorial: Südwestdeutscher Verlag Für Hochschulschriften Mai 2016, 2016
- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 44,90
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Fluid-structure interaction physical processes are very complex, non linear in nature and can not be solved analytically. In fact experimental setups are essential to provide reliable data. However, these are generally associated with enormous costs, which is why the demand for numerical simulations as development tool is increasing rapidly. In this study, an Arbitrary Lagrangian-Eulerian (ALE) formulation is employed in a fully coupled monolithic way, considering the problem as one continuum. The mathematical description and the numerical schemes are designed in such a way that more complicated constitutive relations (and more realistic for biomechanics applications) for the fluid as well as the structural part can be easily incorporated. The aim is to study the interaction of the elastic walls of the aneurysm with the geometrical shape of the implanted stent structure. This study can be seen as a basic step towards the understanding of the resulting complex flow phenomena so that in future aneurysm rupture shall be suppressed by an optimal setting for the implanted stent geometry. The optimization of fluid structure interaction problems are also investigated to set the benchmark. 152 pp. Englisch. …

Idioma: Inglés
Editorial: Südwestdeutscher Verlag für Hochschulschriften, 2016
- Tapa blanda
- Impresión bajo demanda
Librería: moluna, Greven, Alemaniamoluna
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 37,98
Envío por EUR 48,99Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Razzaq MudassarHe has received his doctorate degree from TU Dortmund in 2011. He is scholarship holder of DAAD for PhD studies. He was part of the projects funded by BMBF. He is working as a senior scientific researcher with addition. …

- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 65,41
Envío por EUR 35,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Fluid-structure interaction physical processes are very complex, non linear in nature and can not be solved analytically. In fact experimental setups are essential to provide reliable data. However, these are generally associated with enormous costs, which is why the demand for numerical simulations as development tool is increasing rapidly. In this study, an Arbitrary Lagrangian-Eulerian (ALE) formulation is employed in a fully coupled monolithic way, considering the problem as one continuum. The mathematical description and the numerical schemes are designed in such a way that more complicated constitutive relations (and more realistic for biomechanics applications) for the fluid as well as the structural part can be easily incorporated. The aim is to study the interaction of the elastic walls of the aneurysm with the geometrical shape of the implanted stent structure. This study can be seen as a basic step towards the understanding of the resulting complex flow phenomena so that in future aneurysm rupture shall be suppressed by an optimal setting for the implanted stent geometry. The optimization of fluid structure interaction problems are also investigated to set the benchmark.…

Idioma: Inglés
Editorial: Südwestdeutscher Verlag Für Hochschulschriften Mai 2016, 2016
- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 44,90
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Fluid-structure interaction physical processes are very complex, non linear in nature and can not be solved analytically. In fact experimental setups are essential to provide reliable data. However, these are generally associated with enormous costs, which is why the demand for numerical simulations as development tool is increasing rapidly. In this study, an Arbitrary Lagrangian-Eulerian (ALE) formulation is employed in a fully coupled monolithic way, considering the problem as one continuum. The mathematical description and the numerical schemes are designed in such a way that more complicated constitutive relations (and more realistic for biomechanics applications) for the fluid as well as the structural part can be easily incorporated. The aim is to study the interaction of the elastic walls of the aneurysm with the geometrical shape of the implanted stent structure. This study can be seen as a basic step towards the understanding of the resulting complex flow phenomena so that in future aneurysm rupture shall be suppressed by an optimal setting for the implanted stent geometry. The optimization of fluid structure interaction problems are also investigated to set the benchmark.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 152 pp. Englisch.…