ISBN: 9783668676176 - effect of uneven cooling on performance of air-cooled condenser (5 resultados)

- Tapa blanda
Librería: California Books, Miami, FL, Estados Unidos de AmericaCalifornia Books
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 26,81
Envío por EUR 2,69Se envía dentro de Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New.

- Tapa blanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 17,95
Envío por EUR 35,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponible
Taschenbuch. Condición: Neu. Druck auf Anfrage Neuware - Printed after ordering - Scientific Essay from the year 2017 in the subject Physics - Thermodynamics, , course: Heat transfer engineering, language: English, abstract: Air-cooled condensers ('ACC') operating in vacuum are widely used at the cold end of contemporary thermal power plants. Proper functioning of the condenser is paramount for power plant efficiency.To adapt to changing process conditions because of changed ambient air temperature or power station load ACC streets are either taken out of or into service or, module fan speed settings are selected appropriately. Even if all fans are running at same speed local variations of cooling air flow may arise as a consequence of e.g. fan location or local wind impact. The designer must ensure that no negative effect (i.e. no cold spot) may evolve at the steam side of the ACC caused by uneven air side cooling or fan control.The following note describes a theoretical method to assess the effect of air flow variations on ACC performance and provides simple rules to avoid potentially risky situations. An important role for safe operation plays the size of the secondary condenser. The procedure may be used as a guideline for proper sizing of the secondary condenser with respect to airflow maldistribution.…

- Tapa blanda
Librería: preigu, Osnabrück, Alemaniapreigu
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 17,95
Envío por EUR 70,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 5 disponibles
Taschenbuch. Condición: Neu. Effect of Uneven Cooling on Performance of Air-Cooled Condenser | Hans Georg Schrey | Taschenbuch | 28 S. | Englisch | 2018 | GRIN Verlag | EAN 9783668676176 | Verantwortliche Person für die EU: GRIN Publishing GmbH, Waltherstr. 23, 80337 München, info[at]grin[dot]com | Anbieter: preigu.…

- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 17,95
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Scientific Essay from the year 2017 in the subject Physics - Thermodynamics, , course: Heat transfer engineering, language: English, abstract: Air-cooled condensers ('ACC') operating in vacuum are widely used at the cold end of contemporary thermal power plants. Proper functioning of the condenser is paramount for power plant efficiency.To adapt to changing process conditions because of changed ambient air temperature or power station load ACC streets are either taken out of or into service or, module fan speed settings are selected appropriately. Even if all fans are running at same speed local variations of cooling air flow may arise as a consequence of e.g. fan location or local wind impact. The designer must ensure that no negative effect (i.e. no cold spot) may evolve at the steam side of the ACC caused by uneven air side cooling or fan control.The following note describes a theoretical method to assess the effect of air flow variations on ACC performance and provides simple rules to avoid potentially risky situations. An important role for safe operation plays the size of the secondary condenser. The procedure may be used as a guideline for proper sizing of the secondary condenser with respect to airflow maldistribution. 28 pp. Englisch.…

- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 17,95
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponible
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Scientific Essay from the year 2017 in the subject Physics - Thermodynamics, , course: Heat transfer engineering, language: English, abstract: Air-cooled condensers (¿ACC¿) operating in vacuum are widely used at the cold end of contemporary thermal power plants. Proper functioning of the condenser is paramount for power plant efficiency.To adapt to changing process conditions because of changed ambient air temperature or power station load ACC streets are either taken out of or into service or, module fan speed settings are selected appropriately. Even if all fans are running at same speed local variations of cooling air flow may arise as a consequence of e.g. fan location or local wind impact. The designer must ensure that no negative effect (i.e. no cold spot) may evolve at the steam side of the ACC caused by uneven air side cooling or fan control.The following note describes a theoretical method to assess the effect of air flow variations on ACC performance and provides simple rules to avoid potentially risky situations. An important role for safe operation plays the size of the secondary condenser. The procedure may be used as a guideline for proper sizing of the secondary condenser with respect to airflow maldistribution.Books on Demand GmbH, Überseering 33, 22297 Hamburg 28 pp. Englisch.…