Isbn: 9783659970610 - turkish lrfd bridge design method for slab on steel plate girders: calibration of load and resistance factors to be used in bridge design in turkey (4 resultados)

- Tapa blanda
Librería: moluna, Greven, Alemaniamoluna
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 46,18
Envío por EUR 48,99Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New.

- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 55,90
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Steel composite I-girder bridges are usually used to span between 50 to 80 meters in Turkey. In a typical Turkish bridge design, a modified version of the AASHTO Load Factor Design or Allowable Stress Design requirements are used until now. The recent switch of the US bridge codes to LRFD method also necessitates the calibration of the new design of the Turkish bridges based on the LRFD system. The main aim of this study is to define a new type of live (truck) load to be used in the basic gravity load combination, as well as to develop the corresponding load factors to be implemented in the design of steel composite I-girder bridges. In such studies, usually a target reliability index is selected to reflect the safety level of current design practice based on the uncertainties associated with the design parameters. For the basic gravity load combination, which includes the dead and live loads, a minimum target reliability of 4.00 is selected, instead of 3.50 that have been used in US. In the statistical computations of the reliability index, the quantification of uncertainties is made based on local data supplemented by information compiled from relevant international literature. 132 pp. Englisch.…

- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 55,90
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponible
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Steel composite I-girder bridges are usually used to span between 50 to 80 meters in Turkey. In a typical Turkish bridge design, a modified version of the AASHTO Load Factor Design or Allowable Stress Design requirements are used until now. The recent switch of the US bridge codes to LRFD method also necessitates the calibration of the new design of the Turkish bridges based on the LRFD system. The main aim of this study is to define a new type of live (truck) load to be used in the basic gravity load combination, as well as to develop the corresponding load factors to be implemented in the design of steel composite I-girder bridges. In such studies, usually a target reliability index is selected to reflect the safety level of current design practice based on the uncertainties associated with the design parameters. For the basic gravity load combination, which includes the dead and live loads, a minimum target reliability of 4.00 is selected, instead of 3.50 that have been used in US. In the statistical computations of the reliability index, the quantification of uncertainties is made based on local data supplemented by information compiled from relevant international literature.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 132 pp. Englisch.…

- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 55,90
Envío por EUR 61,08Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponible
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Steel composite I-girder bridges are usually used to span between 50 to 80 meters in Turkey. In a typical Turkish bridge design, a modified version of the AASHTO Load Factor Design or Allowable Stress Design requirements are used until now. The recent switch of the US bridge codes to LRFD method also necessitates the calibration of the new design of the Turkish bridges based on the LRFD system. The main aim of this study is to define a new type of live (truck) load to be used in the basic gravity load combination, as well as to develop the corresponding load factors to be implemented in the design of steel composite I-girder bridges. In such studies, usually a target reliability index is selected to reflect the safety level of current design practice based on the uncertainties associated with the design parameters. For the basic gravity load combination, which includes the dead and live loads, a minimum target reliability of 4.00 is selected, instead of 3.50 that have been used in US. In the statistical computations of the reliability index, the quantification of uncertainties is made based on local data supplemented by information compiled from relevant international literature.…