ISBN: 9783659781438 - energy performance modelling and heat recovery efficiency assessment: energy efficient hvac system determination and rotary heat exchanger's performance assessment (4 resultados)

- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 28,90
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This extended research investigates and analyzes a typical multi-zone office building's annual energy performance. The aim is to evaluate the HVAC system's and HR unit's performance in order to conduct the most efficient heating and cooling solution for temperate climate conditions. The energy performance of four HVAC system types (heat pump - air to air, gas - electricity, electrical and fan coil system) were analyzed, compared and evaluated on a virtual office building model in order to assess the total annual energy performance and to determine the efficiency of the HR unit's application. Further, the parameters of an energy efficient building envelope, HVAC system, internal loads, building operation schedules and occupancy intervals were implemented into the multi-zone analysis model. The investigation was conducted in EnergyPlus simulation engine using thermodynamic algorithms and surface/air heat balance modules. The comparison and evaluation of the obtained results was achieved through the conversion of the calculated total energy demand into primary energy. 52 pp. Englisch.…

- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 34,74
Envío por EUR 35,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponible
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This extended research investigates and analyzes a typical multi-zone office building's annual energy performance. The aim is to evaluate the HVAC system's and HR unit's performance in order to conduct the most efficient heating and cooling solution for temperate climate conditions. The energy performance of four HVAC system types (heat pump - air to air, gas - electricity, electrical and fan coil system) were analyzed, compared and evaluated on a virtual office building model in order to assess the total annual energy performance and to determine the efficiency of the HR unit's application. Further, the parameters of an energy efficient building envelope, HVAC system, internal loads, building operation schedules and occupancy intervals were implemented into the multi-zone analysis model. The investigation was conducted in EnergyPlus simulation engine using thermodynamic algorithms and surface/air heat balance modules. The comparison and evaluation of the obtained results was achieved through the conversion of the calculated total energy demand into primary energy.…

- Tapa blanda
- Impresión bajo demanda
Librería: moluna, Greven, Alemaniamoluna
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 26,05
Envío por EUR 48,99Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: Más de 20 disponibles
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: L. Harmati NorbertNorbert L. Harmati, D.Sc. holds a scientific doctorate degree in architecture - building performance (BP) simulation and energy efficiency. He graduated on the Faculty of Technical Sciences in Novi Sad, Serbia, firs.…

- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 28,90
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponible
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This extended research investigates and analyzes a typical multi-zone office building's annual energy performance. The aim is to evaluate the HVAC system's and HR unit's performance in order to conduct the most efficient heating and cooling solution for temperate climate conditions. The energy performance of four HVAC system types (heat pump - air to air, gas - electricity, electrical and fan coil system) were analyzed, compared and evaluated on a virtual office building model in order to assess the total annual energy performance and to determine the efficiency of the HR unit's application. Further, the parameters of an energy efficient building envelope, HVAC system, internal loads, building operation schedules and occupancy intervals were implemented into the multi-zone analysis model. The investigation was conducted in EnergyPlus simulation engine using thermodynamic algorithms and surface/air heat balance modules. The comparison and evaluation of the obtained results was achieved through the conversion of the calculated total energy demand into primary energy.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 52 pp. Englisch.…