Isbn: 9783659155932 - calibration of a serial robot using a laser tracker: calibration of the abb irb1600-6/1.45 robot with a faro ion laser tracker (4 resultados)

ISBN: 
Refinar con la Búsqueda avanzada

Filtrar la búsqueda

  • Libros (4)

  • Nuevo (4)

a

Intervalo de precios personalizado (EUR)

a

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2012

    3659155934 / 9783659155932

    • Tapa blanda

    Librería: preigu, Osnabrück, Alemaniapreigu

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 236,00

    Envío por EUR 70,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 5 disponibles

    Taschenbuch. Condición: Neu. Calibration of a Serial Robot Using a Laser Tracker | Calibration of the ABB IRB1600-6/1.45 robot with a Faro ION laser tracker | Albert Nubiola | Taschenbuch | 160 S. | Englisch | 2012 | LAP LAMBERT Academic Publishing | EAN 9783659155932 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

  • Idioma: Inglés

    Editorial: LAP Lambert Academic Publishing Jul 2012, 2012

    3659155934 / 9783659155932

    • Tapa blanda
    • Impresión bajo demanda

    Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, AlemaniaBuchWeltWeit Ludwig Meier e.K.

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 59,00

    Envío por EUR 23,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 2 disponibles

    Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The positioning performance of the industrial robot ABB IRB 1600-6/1.45 is deeply studied with a Faro ION laser tracker. Axes 2, 3 and 6 are found to have a non-geometrical behaviour. Different robot models are taken into account for calibration. The level-3 model takes into account the geometrical defaults as well as four error parameters related to stiffness in axes 2 and 3, plus four other error parameters used to fit a second-order Fourier series to the non-linearity of axis 6. The Nelder-Mead technique is used to find the error parameters of the model. The ISO 9283 tests are found to be not complete enough to validate the position performance of the robot. An extensive validation procedure is applied in addition to the ISO 9283 tests. Several tests are also applied to the Faro laser tracker to validate its precision, repeatability and stability. Repeatability tests and stabilization tests are also performed to the calibrated robot. Finally, circular tests are applied with a Renishaw QC20-W telescopic bar to validate the improvement of the robot's accuracy. 160 pp. Englisch.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing, 2012

    3659155934 / 9783659155932

    • Tapa blanda
    • Impresión bajo demanda

    Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 59,00

    Envío por EUR 35,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The positioning performance of the industrial robot ABB IRB 1600-6/1.45 is deeply studied with a Faro ION laser tracker. Axes 2, 3 and 6 are found to have a non-geometrical behaviour. Different robot models are taken into account for calibration. The level-3 model takes into account the geometrical defaults as well as four error parameters related to stiffness in axes 2 and 3, plus four other error parameters used to fit a second-order Fourier series to the non-linearity of axis 6. The Nelder-Mead technique is used to find the error parameters of the model. The ISO 9283 tests are found to be not complete enough to validate the position performance of the robot. An extensive validation procedure is applied in addition to the ISO 9283 tests. Several tests are also applied to the Faro laser tracker to validate its precision, repeatability and stability. Repeatability tests and stabilization tests are also performed to the calibrated robot. Finally, circular tests are applied with a Renishaw QC20-W telescopic bar to validate the improvement of the robot's accuracy.…

  • Idioma: Inglés

    Editorial: LAP LAMBERT Academic Publishing Jul 2012, 2012

    3659155934 / 9783659155932

    • Tapa blanda
    • Impresión bajo demanda

    Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000

    Vendedor de 5 estrellas
    Contactar con el vendedor

    Condición: Nuevo

    EUR 236,00

    Envío por EUR 60,00 
    Se envía de Alemania a Estados Unidos de America

    Cantidad disponible: 1 disponible

    Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The positioning performance of the industrial robot ABB IRB 1600-6/1.45 is deeply studied with a Faro ION laser tracker. Axes 2, 3 and 6 are found to have a non-geometrical behaviour. Different robot models are taken into account for calibration. The level-3 model takes into account the geometrical defaults as well as four error parameters related to stiffness in axes 2 and 3, plus four other error parameters used to fit a second-order Fourier series to the non-linearity of axis 6. The Nelder-Mead technique is used to find the error parameters of the model. The ISO 9283 tests are found to be not complete enough to validate the position performance of the robot. An extensive validation procedure is applied in addition to the ISO 9283 tests. Several tests are also applied to the Faro laser tracker to validate its precision, repeatability and stability. Repeatability tests and stabilization tests are also performed to the calibrated robot. Finally, circular tests are applied with a Renishaw QC20-W telescopic bar to validate the improvement of the robot's accuracy.OmniScriptum SRL, Str. Armeneasca 28/1, office 1, 2012 Chisinau 160 pp. Englisch.…