Samer asad (4 resultados)

- Tapa blanda
- Impresión bajo demanda
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, , AlemaniaBuchWeltWeit Ludwig Meier e.K.
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 59,90
Envío por EUR 23,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 2 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A series of tests were conducted on the system to produce hot air from thermal receiver, and after several experiments on the system, it was found that the most successful test was accomplished by using a combination of graphite mat…erial and quartz mirror on the thermal receiver. Solar radiation for the site of testing (32.01° N, 35.87° E) was estimated. According to the performed tests, the temperature at the focal point of dish was between 960-1023 °C at 10:00 AM until 4:40 PM, and the maximum hot air temperature recorded at the outlet of thermal receiver was 421 °C. System efficiency of the system was around 27.07%. However, there were some factors of losses in concentrating the sunrays on the thermal receiver during system operation; those factors are related to tracking imperfections and shading effects caused by thermal receiver and structural supported beams. 104 pp. Englisch.

- Tapa blanda
- Impresión bajo demanda
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemaniabuchversandmimpf2000
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 59,90
Envío por EUR 60,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -A series of tests were conducted on the system to produce hot air from thermal receiver, and after several experiments on the system, it was found that the most successful test was accomplished by using a combination of graphite materia…l and quartz mirror on the thermal receiver. Solar radiation for the site of testing (32.01° N, 35.87° E) was estimated. According to the performed tests, the temperature at the focal point of dish was between 960-1023 °C at 10:00 AM until 4:40 PM, and the maximum hot air temperature recorded at the outlet of thermal receiver was 421 °C. System efficiency of the system was around 27.07%. However, there were some factors of losses in concentrating the sunrays on the thermal receiver during system operation; those factors are related to tracking imperfections and shading effects caused by thermal receiver and structural supported beams.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 104 pp. Englisch.

- Tapa blanda
- Impresión bajo demanda
Librería: preigu, Osnabrück, Alemaniapreigu
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 51,05
Envío por EUR 70,00Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 5 disponibles
Taschenbuch. Condición: Neu. Design and Testing of Dish System Using CSP with Thermal Heat Storage | Samer As'ad (u. a.) | Taschenbuch | Englisch | 2018 | Scholars' Press | EAN 9786202308724 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: prei…gu Print on Demand.

- Tapa blanda
- Impresión bajo demanda
Librería: AHA-BUCH GmbH, Einbeck, AlemaniaAHA-BUCH GmbH
Contactar con el vendedorVendedor de 5 estrellasCondición: Nuevo
EUR 60,62
Envío por EUR 60,87Se envía de Alemania a Estados Unidos de AmericaCantidad disponible: 1 disponibles
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A series of tests were conducted on the system to produce hot air from thermal receiver, and after several experiments on the system, it was found that the most successful test was accomplished by using a combination of graphite material… and quartz mirror on the thermal receiver. Solar radiation for the site of testing (32.01° N, 35.87° E) was estimated. According to the performed tests, the temperature at the focal point of dish was between 960-1023 °C at 10:00 AM until 4:40 PM, and the maximum hot air temperature recorded at the outlet of thermal receiver was 421 °C. System efficiency of the system was around 27.07%. However, there were some factors of losses in concentrating the sunrays on the thermal receiver during system operation; those factors are related to tracking imperfections and shading effects caused by thermal receiver and structural supported beams.