Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A series of tests were conducted on the system to produce hot air from thermal receiver, and after several experiments on the system, it was found that the most successful test was accomplished by using a combination of graphite material and quartz mirror on the thermal receiver. Solar radiation for the site of testing (32.01° N, 35.87° E) was estimated. According to the performed tests, the temperature at the focal point of dish was between 960-1023 °C at 10:00 AM until 4:40 PM, and the maximum hot air temperature recorded at the outlet of thermal receiver was 421 °C. System efficiency of the system was around 27.07%. However, there were some factors of losses in concentrating the sunrays on the thermal receiver during system operation; those factors are related to tracking imperfections and shading effects caused by thermal receiver and structural supported beams. 104 pp. Englisch. Nº de ref. del artículo: 9786202308724
Cantidad disponible: 2 disponibles
Librería: Books Puddle, New York, NY, Estados Unidos de America
Condición: New. Nº de ref. del artículo: 26394700448
Cantidad disponible: 4 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: As ad SamerDr. Samer received his PhD degree in Mechanical Engineering from the University of Jordan. He is currently the Head of Renewable Energy Engineering Department in Middle East University-Jordan. His research interests are fo. Nº de ref. del artículo: 507412380
Cantidad disponible: Más de 20 disponibles
Librería: Majestic Books, Hounslow, Reino Unido
Condición: New. Print on Demand. Nº de ref. del artículo: 401676671
Cantidad disponible: 4 disponibles
Librería: Biblios, Frankfurt am main, HESSE, Alemania
Condición: New. PRINT ON DEMAND. Nº de ref. del artículo: 18394700458
Cantidad disponible: 4 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -A series of tests were conducted on the system to produce hot air from thermal receiver, and after several experiments on the system, it was found that the most successful test was accomplished by using a combination of graphite material and quartz mirror on the thermal receiver. Solar radiation for the site of testing (32.01° N, 35.87° E) was estimated. According to the performed tests, the temperature at the focal point of dish was between 960-1023 °C at 10:00 AM until 4:40 PM, and the maximum hot air temperature recorded at the outlet of thermal receiver was 421 °C. System efficiency of the system was around 27.07%. However, there were some factors of losses in concentrating the sunrays on the thermal receiver during system operation; those factors are related to tracking imperfections and shading effects caused by thermal receiver and structural supported beams.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 104 pp. Englisch. Nº de ref. del artículo: 9786202308724
Cantidad disponible: 1 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Design and Testing of Dish System Using CSP with Thermal Heat Storage | Samer As'ad (u. a.) | Taschenbuch | Englisch | 2018 | Scholars' Press | EAN 9786202308724 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu Print on Demand. Nº de ref. del artículo: 120533002
Cantidad disponible: 5 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A series of tests were conducted on the system to produce hot air from thermal receiver, and after several experiments on the system, it was found that the most successful test was accomplished by using a combination of graphite material and quartz mirror on the thermal receiver. Solar radiation for the site of testing (32.01° N, 35.87° E) was estimated. According to the performed tests, the temperature at the focal point of dish was between 960-1023 °C at 10:00 AM until 4:40 PM, and the maximum hot air temperature recorded at the outlet of thermal receiver was 421 °C. System efficiency of the system was around 27.07%. However, there were some factors of losses in concentrating the sunrays on the thermal receiver during system operation; those factors are related to tracking imperfections and shading effects caused by thermal receiver and structural supported beams. Nº de ref. del artículo: 9786202308724
Cantidad disponible: 1 disponibles