FEASIBILITY STUDY OF USING PULSATING HEAT PIPES IN WASTE HEAT RECOVERY | AN ECONOMICAL TECHNIQUE TO CAPTURE WASTE HEAT AND APPLY IT FOR FURTHER INDUSTRIAL APPLICATIONS THEREBY SAVING ENERGY

Pranab Barua

ISBN 10: 3843364818 ISBN 13: 9783843364812
Editorial: LAP LAMBERT Academic Publishing, 2010
Nuevos Taschenbuch

Librería: preigu, Osnabrück, Alemania Calificación del vendedor: 5 de 5 estrellas Valoración 5 estrellas, Más información sobre las valoraciones de los vendedores

Vendedor de AbeBooks desde 5 de agosto de 2024

Este artículo en concreto ya no está disponible.

Descripción

Descripción:

FEASIBILITY STUDY OF USING PULSATING HEAT PIPES IN WASTE HEAT RECOVERY | AN ECONOMICAL TECHNIQUE TO CAPTURE WASTE HEAT AND APPLY IT FOR FURTHER INDUSTRIAL APPLICATIONS THEREBY SAVING ENERGY | Pranab Barua | Taschenbuch | 184 S. | Englisch | 2010 | LAP LAMBERT Academic Publishing | EAN 9783843364812 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. N° de ref. del artículo 107256713

Denunciar este artículo

Sinopsis:

Heat pipe heat exchangers are very effective devices for waste heat recovery. To check for its efficiency, we must study the manner in which it helps to remove heat from a system concerned. The higher the heat removal rate, the more efficiently it can recover heat that would otherwise get wasted. In our work, it was chosen to establish mathematical models of fall of temperature with respect to time in the condenser section of pulsating heat pipes due to natural cooling from a certain higher temperature to the room temperature for various diameters of pipes made of copper and for various lengths of the evaporator section using water as the working fluid. We have found that temperature decreases exponentially in time both for single loop and for multiple loops. For a fixed length of the evaporator section, we have seen that temperature falls faster for smaller diameter of the pipe. The rate of change of temperature has been seen to rise with increase in the number of turns in the evaporator section. We have found further that the instantaneous failure rate of falling temperature rises exponentially with increase in the number of turns in the evaporator section.

Reseña del editor: Heat pipe heat exchangers are very effective devices for waste heat recovery. To check for its efficiency, we must study the manner in which it helps to remove heat from a system concerned. The higher the heat removal rate, the more efficiently it can recover heat that would otherwise get wasted. In our work, it was chosen to establish mathematical models of fall of temperature with respect to time in the condenser section of pulsating heat pipes due to natural cooling from a certain higher temperature to the room temperature for various diameters of pipes made of copper and for various lengths of the evaporator section using water as the working fluid. We have found that temperature decreases exponentially in time both for single loop and for multiple loops. For a fixed length of the evaporator section, we have seen that temperature falls faster for smaller diameter of the pipe. The rate of change of temperature has been seen to rise with increase in the number of turns in the evaporator section. We have found further that the instantaneous failure rate of falling temperature rises exponentially with increase in the number of turns in the evaporator section.

"Sobre este título" puede pertenecer a otra edición de este libro.

Detalles bibliográficos

Título: FEASIBILITY STUDY OF USING PULSATING HEAT ...
Editorial: LAP LAMBERT Academic Publishing
Año de publicación: 2010
Encuadernación: Taschenbuch
Condición: Neu

Los mejores resultados en AbeBooks