This work presents a simple and reliable optimization approach to optimally allocate the thyristor-controlled series compensator (TCSC) and unified power flow controller (UPFC) in wind power connected deregulated power system. In the presented approach, only optimal power flow (OPF) formulation of MATPOWER is used and the rest work has been done in the MATLAB coding to develop the proposed approach. The presented approach is based on step by step variation in control parameters of the TCSC and UPFC device. Results have been determined for all possible locations, compensation level, reactance of TCSC and UPFC, reactive power injection or absorption, maximization of social welfare, maximization of profit with minimization of objective function. The locational marginal pricing (LMP) has reduced by proper placement of FACTS devices by presented approach. System voltage also improved by using the UPFC. The double auction bidding model has been used in this work. The effectiveness of the presented approach for optimal location of TCSC & UPFC has been tested and analyzed on modified IEEE 14-bus and modified IEEE 118-bus systems.
"Sinopsis" puede pertenecer a otra edición de este libro.
Sus derechos de garantía legal: Todos los consumidores de la UE se benefician de al menos dos años de protección de garantía legal para cualquier bien de consumo que se venda en la UE. Ver más
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This work presents a simple and reliable optimization approach to optimally allocate the thyristor-controlled series compensator (TCSC) and unified power flow controller (UPFC) in wind power connected deregulated power system. In the presented approach, only optimal power flow (OPF) formulation of MATPOWER is used and the rest work has been done in the MATLAB coding to develop the proposed approach. The presented approach is based on step by step variation in control parameters of the TCSC and UPFC device. Results have been determined for all possible locations, compensation level, reactance of TCSC and UPFC, reactive power injection or absorption, maximization of social welfare, maximization of profit with minimization of objective function. The locational marginal pricing (LMP) has reduced by proper placement of FACTS devices by presented approach. System voltage also improved by using the UPFC. The double auction bidding model has been used in this work. The effectiveness of the presented approach for optimal location of TCSC & UPFC has been tested and analyzed on modified IEEE 14-bus and modified IEEE 118-bus systems. 124 pp. Englisch. Nº de ref. del artículo: 9786202529655
Cantidad disponible: 2 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Dawn SubhojitDr. Dawn has completed his M.Tech & Ph.D. from NIT Silchar, India in Power & Energy Systems Engineering. He has published many research papers in reputed International Journals/Conferences in the field of Power System. H. Nº de ref. del artículo: 494826443
Cantidad disponible: Más de 20 disponibles
Librería: Books Puddle, Woodside, NY, Estados Unidos de America
Condición: New. Nº de ref. del artículo: 26387673587
Cantidad disponible: 4 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This work presents a simple and reliable optimization approach to optimally allocate the thyristor-controlled series compensator (TCSC) and unified power flow controller (UPFC) in wind power connected deregulated power system. In the presented approach, only optimal power flow (OPF) formulation of MATPOWER is used and the rest work has been done in the MATLAB coding to develop the proposed approach. The presented approach is based on step by step variation in control parameters of the TCSC and UPFC device. Results have been determined for all possible locations, compensation level, reactance of TCSC and UPFC, reactive power injection or absorption, maximization of social welfare, maximization of profit with minimization of objective function. The locational marginal pricing (LMP) has reduced by proper placement of FACTS devices by presented approach. System voltage also improved by using the UPFC. The double auction bidding model has been used in this work. The effectiveness of the presented approach for optimal location of TCSC & UPFC has been tested and analyzed on modified IEEE 14-bus and modified IEEE 118-bus systems. Nº de ref. del artículo: 9786202529655
Cantidad disponible: 1 disponibles
Librería: Majestic Books, Hounslow, Reino Unido
Condición: New. Print on Demand. Nº de ref. del artículo: 393007660
Cantidad disponible: 4 disponibles
Librería: Biblios, Frankfurt am main, HESSE, Alemania
Condición: New. PRINT ON DEMAND. Nº de ref. del artículo: 18387673593
Cantidad disponible: 4 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This work presents a simple and reliable optimization approach to optimally allocate the thyristor-controlled series compensator (TCSC) and unified power flow controller (UPFC) in wind power connected deregulated power system. In the presented approach, only optimal power flow (OPF) formulation of MATPOWER is used and the rest work has been done in the MATLAB coding to develop the proposed approach. The presented approach is based on step by step variation in control parameters of the TCSC and UPFC device. Results have been determined for all possible locations, compensation level, reactance of TCSC and UPFC, reactive power injection or absorption, maximization of social welfare, maximization of profit with minimization of objective function. The locational marginal pricing (LMP) has reduced by proper placement of FACTS devices by presented approach. System voltage also improved by using the UPFC. The double auction bidding model has been used in this work. The effectiveness of the presented approach for optimal location of TCSC & UPFC has been tested and analyzed on modified IEEE 14-bus and modified IEEE 118-bus systems.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 124 pp. Englisch. Nº de ref. del artículo: 9786202529655
Cantidad disponible: 1 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Optimal Placement of FACTS Devices with Wind Generator in Power System | Subhojit Dawn (u. a.) | Taschenbuch | 124 S. | Englisch | 2020 | LAP LAMBERT Academic Publishing | EAN 9786202529655 | Verantwortliche Person für die EU: LAP Lambert Academic Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu. Nº de ref. del artículo: 118433814
Cantidad disponible: 5 disponibles