Doctoral Thesis / Dissertation from the year 2013 in the subject Engineering - Civil Engineering, grade: B, , course: Master of technology - Structural Dynamics, language: English, abstract: Flat-Slab building is very popular from the aesthetic and architectural point of view. From functional aspect a flat-slab building is more efficient than a R.C. frame building. So, construction of Flat-Slab building is increasing also in high seismic zone. Sometimes international building codes remain silent about the seismic response of flat slab buildings. In this paper the response of Flat-Slab building and a normal symmetric R.C. frame building of same dimension have been studied for varying seismic intensities. Static, Response Spectrum, Pushover, and Time history analysis have been performed to assess the performance of the two buildings. The costs of construction for these two buildings have also been compared. An extensive study on lumped plasticity model as per FEMA 356 with varying position of plastic hinge and its effect on pushover curve has also discussed in the paper. The paper also comments on the plastic hinge pattern.
"Sinopsis" puede pertenecer a otra edición de este libro.
Doctoral Thesis / Dissertation from the year 2013 in the subject Engineering - Civil Engineering, grade: B, , course: Master of technology - Structural Dynamics, language: English, abstract: Flat-Slab building is very popular from the aesthetic and architectural point of view. From functional aspect a flat-slab building is more efficient than a R.C. frame building. So, construction of Flat-Slab building is increasing also in high seismic zone. Sometimes international building codes remain silent about the seismic response of flat slab buildings. In this paper the response of Flat-Slab building and a normal symmetric R.C. frame building of same dimension have been studied for varying seismic intensities. Static, Response Spectrum, Pushover, and Time history analysis have been performed to assess the performance of the two buildings. The costs of construction for these two buildings have also been compared. An extensive study on lumped plasticity model as per FEMA 356 with varying position of plastic hinge and its effect on pushover curve has also discussed in the paper. The paper also comments on the plastic hinge pattern.
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: GreatBookPrices, Columbia, MD, Estados Unidos de America
Condición: New. Nº de ref. del artículo: 20136241-n
Cantidad disponible: Más de 20 disponibles
Librería: BargainBookStores, Grand Rapids, MI, Estados Unidos de America
Paperback or Softback. Condición: New. Assessment of R. C. Flat Slab Building. Book. Nº de ref. del artículo: BBS-9783656493211
Cantidad disponible: 5 disponibles
Librería: California Books, Miami, FL, Estados Unidos de America
Condición: New. Nº de ref. del artículo: I-9783656493211
Cantidad disponible: Más de 20 disponibles
Librería: GreatBookPrices, Columbia, MD, Estados Unidos de America
Condición: As New. Unread book in perfect condition. Nº de ref. del artículo: 20136241
Cantidad disponible: Más de 20 disponibles
Librería: Books Puddle, Woodside, NY, Estados Unidos de America
Condición: New. pp. 52. Nº de ref. del artículo: 26128413543
Cantidad disponible: 1 disponibles
Librería: Majestic Books, Hounslow, Reino Unido
Condición: New. pp. 52 424:B&W 5.83 x 8.27 in or 210 x 148 mm (A5) Perfect Bound on Creme w/Matte Lam. Nº de ref. del artículo: 131125432
Cantidad disponible: 1 disponibles
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Doctoral Thesis / Dissertation from the year 2013 in the subject Engineering - Civil Engineering, grade: B, , course: Master of technology - Structural Dynamics, language: English, abstract: Flat-Slab building is very popular from the aesthetic and architectural point of view. From functional aspect a flat-slab building is more efficient than a R.C. frame building. So, construction of Flat-Slab building is increasing also in high seismic zone. Sometimes international building codes remain silent about the seismic response of flat slab buildings. In this paper the response of Flat-Slab building and a normal symmetric R.C. frame building of same dimension have been studied for varying seismic intensities. Static, Response Spectrum, Pushover, and Time history analysis have been performed to assess the performance of the two buildings. The costs of construction for these two buildings have also been compared. An extensive study on lumped plasticity model as per FEMA 356 with varying position of plastic hinge and its effect on pushover curve has also discussed in the paper. The paper also comments on the plastic hinge pattern. 52 pp. Englisch. Nº de ref. del artículo: 9783656493211
Cantidad disponible: 2 disponibles
Librería: GreatBookPricesUK, Woodford Green, Reino Unido
Condición: New. Nº de ref. del artículo: 20136241-n
Cantidad disponible: Más de 20 disponibles
Librería: GreatBookPricesUK, Woodford Green, Reino Unido
Condición: As New. Unread book in perfect condition. Nº de ref. del artículo: 20136241
Cantidad disponible: Más de 20 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. Druck auf Anfrage Neuware - Printed after ordering - Doctoral Thesis / Dissertation from the year 2013 in the subject Engineering - Civil Engineering, grade: B, , course: Master of technology - Structural Dynamics, language: English, abstract: Flat-Slab building is very popular from the aesthetic and architectural point of view. From functional aspect a flat-slab building is more efficient than a R.C. frame building. So, construction of Flat-Slab building is increasing also in high seismic zone. Sometimes international building codes remain silent about the seismic response of flat slab buildings. In this paper the response of Flat-Slab building and a normal symmetric R.C. frame building of same dimension have been studied for varying seismic intensities. Static, Response Spectrum, Pushover, and Time history analysis have been performed to assess the performance of the two buildings. The costs of construction for these two buildings have also been compared. An extensive study on lumped plasticity model as per FEMA 356 with varying position of plastic hinge and its effect on pushover curve has also discussed in the paper. The paper also comments on the plastic hinge pattern. Nº de ref. del artículo: 9783656493211
Cantidad disponible: 1 disponibles