Molecular Alternatives to Indicator and Pathogen Detection (Paperback)

Idioma: inglés

Editorial: IWA Publishing, London, 2006

1843397358 / 9781843397359

  • Primera edición
  • Tapa blanda
  • Nuevo
Ver todos los detalles

Librería: Grand Eagle Retail, Bensenville, IL, Estados Unidos de AmericaGrand Eagle Retail

Vendedor de 5 estrellas

Vendedor de AbeBooks desde 12 de octubre de 2005

Ver los artículos de este vendedor
Tapa blanda

Condición: Nuevo

EUR 149,21

 Gastos de envío gratis 
Se envía dentro de Estados Unidos de America

Cantidad disponible: 1 disponibles

Añadir al carrito
Devoluciones gratuitas de 30 días

Descripción del artículo del vendedor

Paperback. Microbial quality of water is a prime public health concern in today's world. To protect public health, the World Health Organization and the U.S. Environmental Protection Agency have established microbial pollution indicator standards and recommended routine monitoring of water for both total and fecal coliforms. However, the adequacy of current water quality standards to indicate the presence or absence of human pathogens is still questionable. For example, human viruses are more resistant to sewage treatment processes and environmental conditions than bacterial indicators and therefore may pose a substantial threat. It is now recognized that the absence, or a low concentration, of indicator organisms in water may not adequately reflect the absence of human viruses. In our previous study of southern California coastal waters, we found over 30% of coastal waters tested contained human viruses, and the presence of these viruses did not correlate with an elevated level of bacterial indicators (Jiang et al. 2000). The goal of this research is to develop and validate a molecular method for rapid and specific detection of microbial contaminants including human viruses and bacterial indicators in treated sewage effluents and receiving waters. Microbial quality of water is a prime public health concern in today's world. To protect public health, the World Health Organization and the U.S. Environmental Protection Agency have established microbial pollution indicator standards and recommended routine monitoring of water for both total and fecal coliforms (Dufour, 1984, U.S. EPA 1986,1994, WHO 1993). However, the adequacy of current water quality standards to indicate the presence or absence of human pathogens is still questionable. For example, human viruses are more resistant to sewage treatment processes and environmental conditions than bacterial indicators and therefore may pose a substantial threat. It is now recognized that the absence, or a low concentration, of indicator organisms in water may not adequately reflect the absence of human viruses. In our previous study of southern California coastal waters, we found over 30% of coastal waters tested contained human viruses, and the presence of these viruses did not correlate with an elevated level of bacterial indicators (Jiang et al. 2000). The goal of this research is to develop and validate a molecular method for rapid and specific detection of microbial contaminants including human viruses and bacterial indicators in treated sewage effluents and receiving waters. Research Outcomes An extensive search and review of current state of technology for molecular alternatives to indicator and viral pathogen detection was conducted. The results indicate that although real-time PCR methods have been widely applied in the clinical research for detection of human viruses, environmental application of this method is very limited. In addition, there is an urgent need for a method for efficient concentration and purification of human viruses in complex environmental matrixes. During this study, we have designed, tested and optimized real-time quantitative PCR method using specific and degenerate primers and probes targeting at adenoviruses and enterococci, respectively. Experimental testing of real time PCR primers and probes for adenoviruses demonstrated reproducible results at efficiency greater than 90% over a 5-log dynamic range of target concentration. The enterococci real time PCR was efficient at 99% of the time and over a 7-log dynamic range of target concentration. Application of these methods to sewage effluents and coastal waters demonstrated that real-time PCR methods are more sensitive than culturing methods at detection of targets, suggesting a great potential for real-time quantification of microbial contaminants in environments. However, real-time PCR based meth Shipping may be from multiple locations in the US or from the UK, depending on stock availability.

N° de ref. del artículo 9781843397359

Título
Molecular Alternatives to Indicator and Pathogen Detection (Paperback)
Autor
S.C. Jiang
Editorial
IWA Publishing, London
Año de publicación
2006
Estado
new
Encuadernación
Paperback
Idioma
inglés
ISBN 10
1843397358
ISBN 13
9781843397359
Edición
1ª Edición

Grand Eagle Retail

Bensenville, IL, Estados Unidos de America

Vendedor de 5 estrellas

Vendedor de AbeBooks desde 12 de octubre de 2005

Tarifas de envío en Estados Unidos de America

ArtículoDe 6 a 14 días hábilesDe 6 a 16 días hábiles
Primer artículoEUR 0,00EUR 0,00
Los plazos de entrega los establecen los vendedores y varían según el transportista y la ubicación. Los pedidos que pasan por la aduana pueden sufrir retrasos y los compradores son responsables de los aranceles o tarifas asociadas. Los vendedores pueden ponerse en contacto con usted en relación con cargos adicionales para cubrir cualquier aumento en los costes de envío de los artículos.

Métodos de pago

  • Visa
  • Mastercard
  • American Express
  • Carte Bleue
  • Apple Pay
  • Google Pay

Información empresarial del vendedor

APOLLO ONLINE CORP.

605 Geddes Street
Wilmington, DE Estados Unidos de America 19805