Refrigerant Charging and Service Procedures Handbook for Air Conditioning (Paperback)
Idioma: inglés
Editorial: Independently Published, 2026
- Tapa blanda
- Nuevo

Librería: Grand Eagle Retail, Bensenville, IL, Estados Unidos de AmericaGrand Eagle Retail
Vendedor de IberLibro desde 12 de octubre de 2005
Condición: Nuevo
EUR 90,91
Cantidad disponible: 1 disponible
Añadir al carritoDescripción del artículo del vendedor
Paperback. A technician standing at a condensing unit with a set of gauges is making decisions that determine system performance, energy cost, and legal compliance, often within a single service call.Too many of those calls still run on a single gauge reading and a guess. High superheat gets refrigerant added. Low subcooling gets refrigerant added. A restricted filter-drier, a dirty condenser coil, and a failing metering device can all produce the same misleading numbers, and refrigerant keeps getting added until the real fault catches up with the compressor, or with the paperwork required under current federal recovery and recordkeeping rules.This handbook was built as a single procedures-focused reference that follows the logical sequence of a real service call, from first inspection to final documentation, connecting the vapor-compression cycle to the decisions a technician actually makes: choosing the correct charging method for the installed metering device, evacuating and dehydrating to a verified vacuum, confirming a leak before reaching for the recovery machine, and diagnosing charge- and airflow-related faults instead of defaulting to adding refrigerant. Each of its thirteen chapters opens with clear learning objectives, works through complete examples with units carried at every step, and closes with practice problems and provided answers.Inside, you will be able to: Understand the vapor-compression cycle well enough to explain why a superheat or subcooling reading is behaving the way it is, not just what to do when it doesApply weight-based, superheat, and subcooling charging methods correctly, matched to the installed metering device, using worked calculations that carry units at every stepEvacuate and dehydrate a system to a verified micron level and recognize a decay test that points to a leak rather than residual moistureDetect, confirm, and repair leaks, and select recovery and tool practices appropriate to the refrigerant classification involved, including the workspace considerations that apply to mildly flammable refrigerant categoriesWork through a structured diagnostic sequence for charge-related, airflow-related, electrical, and mechanical faultsMeet current federal recordkeeping, evacuation-level, and recovery and reclamation documentation requirements as a built-in part of the service process, not a separate compliance moduleThe book follows the complete arc of a service call across thirteen chapters: refrigeration fundamentals and the pressure-enthalpy relationship; refrigerant properties and regulatory classification, including mildly flammable categories; core federal compliance obligations; tools, instruments, calibration, and safe work practice; system inspection; evacuation and dehydration; refrigerant recovery; charging by weight, superheat, and subcooling; leak detection technologies; leak repair and pressure verification; charge- and airflow-related fault diagnosis; electrical and mechanical component diagnostics; and refrigerant recovery, reclamation, and environmental compliance across a refrigerant's full service life, supported by a glossary and four reference appendices, including a pressure-temperature chart and unit conversion tables.This handbook is written for practicing HVAC technicians, field engineers supporting service operations, and advanced trainees who already hold, or are working toward, federal refrigerant-handling certification. Readers are assumed to have some prior exposure to basic electrical and mechanical concepts; this is a procedures-focused reference rather than a general survey of heating and cooling theory, and it is equally suited to a working reference shelf or a training-program reading list.Take the next step toward diagnosing with evidence instead of habit. Get your cop Shipping may be from multiple locations in the US or from the UK, depending on stock availability.…
N° de ref. del artículo 9798174661219
- Título
- Refrigerant Charging and Service Procedures Handbook for Air Conditioning (Paperback)
- Autor
- Keller Ben
- Editorial
- Independently Published
- Año de publicación
- 2026
- Estado
- new
- Encuadernación
- Paperback
- Idioma
- inglés
- ISBN 13
- 9798174661219
- Serie
- Libro 1 de 2: The HVAC-R Technician's Field Library
Too many of those calls still run on a single gauge reading and a guess. High superheat gets refrigerant added. Low subcooling gets refrigerant added. A restricted filter-drier, a dirty condenser coil, and a failing metering device can all produce the same misleading numbers, and refrigerant keeps getting added until the real fault catches up with the compressor, or with the paperwork required under current federal recovery and recordkeeping rules.
This handbook was built as a single procedures-focused reference that follows the logical sequence of a real service call, from first inspection to final documentation, connecting the vapor-compression cycle to the decisions a technician actually makes: choosing the correct charging method for the installed metering device, evacuating and dehydrating to a verified vacuum, confirming a leak before reaching for the recovery machine, and diagnosing charge- and airflow-related faults instead of defaulting to adding refrigerant. Each of its thirteen chapters opens with clear learning objectives, works through complete examples with units carried at every step, and closes with practice problems and provided answers.
Inside, you will be able to:
- Understand the vapor-compression cycle well enough to explain why a superheat or subcooling reading is behaving the way it is, not just what to do when it does
- Apply weight-based, superheat, and subcooling charging methods correctly, matched to the installed metering device, using worked calculations that carry units at every step
- Evacuate and dehydrate a system to a verified micron level and recognize a decay test that points to a leak rather than residual moisture
- Detect, confirm, and repair leaks, and select recovery and tool practices appropriate to the refrigerant classification involved, including the workspace considerations that apply to mildly flammable refrigerant categories
- Work through a structured diagnostic sequence for charge-related, airflow-related, electrical, and mechanical faults
- Meet current federal recordkeeping, evacuation-level, and recovery and reclamation documentation requirements as a built-in part of the service process, not a separate compliance module
This handbook is written for practicing HVAC technicians, field engineers supporting service operations, and advanced trainees who already hold, or are working toward, federal refrigerant-handling certification. Readers are assumed to have some prior exposure to basic electrical and mechanical concepts; this is a procedures-focused reference rather than a general survey of heating and cooling theory, and it is equally suited to a working reference shelf or a training-program reading list.
Take the next step toward diagnosing with evidence instead of habit. Get your copy and start building a reference you can return to on every service call
“Sinopsis” puede pertenecer a otra edición de este título.
Grand Eagle Retail
Bensenville, IL, Estados Unidos de America
Vendedor de IberLibro desde 12 de octubre de 2005
Tarifas de envío en Estados Unidos de America
| Artículo | De 6 a 14 días hábiles | De 6 a 16 días hábiles |
|---|---|---|
| Primer artículo | EUR 0,00 | EUR 0,00 |
Métodos de pago
Información empresarial del vendedor
APOLLO ONLINE CORP.
605 Geddes Street
Wilmington, DE Estados Unidos de America 19805
Condiciones de venta
We guarantee the condition of every book as it¿s described on the Abebooks web sites. If you¿ve changed
your mind about a book that you¿ve ordered, please use the Ask bookseller a question link to contact us
and we¿ll respond within 2 business days.
Books ship from California and Michigan.
Derecho al desistimiento
Si es un consumidor, puede rescindir el contrato de acuerdo con lo siguiente. Por consumidor se entiende cualquier persona física que actúe con fines ajenos a su actividad comercial, empresarial, oficio o profesión.
Información sobre el derecho de desistimiento
Derecho legal de desistimiento
Tiene derecho a rescindir este contrato en un plazo de 14 días sin dar ningún motivo.
El periodo de desistimiento vencerá a los 14 días desde que usted, o un tercero que no sea el transportista e indicado por usted, adquiera la posesión física del último bien o del último lote o pieza.
Para ejercer el derecho de desistimiento, complete de forma electrónica y envíe una declaración clara en nuestro sitio web, desde "Mis compras" en "Mi cuenta". Le enviaremos sin demora un acuse de recibo de dicho desistimiento a través de un soporte duradero (por ejemplo, por correo electrónico).
Para cumplir con el plazo de desistimiento, basta con que envíe su comunicación relativa al ejercicio del derecho de desistimiento antes de que venza el periodo de desistimiento.
Efectos del desistimiento
Si rescinde este contrato, le reembolsaremos todos los pagos que hayamos recibido de usted, incluidos los gastos de envío (excepto los gastos adicionales que surjan si elige un tipo de envío que no sea el tipo de envío estándar más económico que ofrecemos).
Podemos hacer una deducción del reembolso por la pérdida de valor de cualquier bien suministrado, si la pérdida es el resultado de una manipulación innecesaria por su parte.
Efectuaremos el reembolso sin demoras indebidas y, a más tardar, 14 días después de que se nos informe de su decisión de rescindir este contrato.
Efectuaremos el reembolso utilizando el mismo medio de pago que utilizó para la transacción inicial, a menos que haya acordado expresamente lo contrario; en cualquier caso, no incurrirá en ningún cargo como resultado de dicho reembolso.
Podremos retener el reembolso hasta que hayamos recibido los bienes o hasta que nos haya presentado una prueba de que los ha devuelto, lo que ocurra primero.
Deberá devolver los bienes o entregarlos a Grand Eagle Retail, Bensenville, Illinois, U.S.A., sin demoras indebidas y, en cualquier caso, en un plazo máximo de 14 días a partir del día en que nos comunique su desistimiento del presente contrato. El plazo se cumple si devuelve la mercancía antes de que venza el periodo de 14 días. Tendrá que asumir los gastos directos de devolución de los bienes. Usted solo es responsable de la disminución del valor de los bienes como resultado de una manipulación distinta a la necesaria para establecer la naturaleza, las características y el funcionamiento de los bienes.
Excepciones al derecho de desistimiento
El derecho de desistimiento no se aplica a lo siguiente:
- La entrega de periódicos, diarios o revistas, con la excepción de los contratos de suscripción; y
- El suministro de contenido digital que no se proporcione en un soporte tangible (por ejemplo, en un CD o DVD) si, al hacer el pedido, aceptó que podíamos empezar a entregarlo y que no podría desistir una vez iniciada la entrega.
Condiciones de envío
Orders usually ship within 2 business days. All books within the US ship free of charge. Delivery is 4-14 business days anywhere in the United States.
Books ship from California and Michigan.
If your book order is heavy or oversized, we may contact you to let you know extra shipping is required.