Radiation Beam Collimation Used In Radiotherapy: Radiotherapy. Este artículo no está disponible.
Idioma: inglés
Editorial: Lap Lambert Academic Publishing, 2012
- Tapa blanda
- Nuevo

Librería: Revaluation Books, Exeter, Reino UnidoRevaluation Books
Vendedor de 5 estrellas
Vendedor de IberLibro desde 6 de enero de 2003
No disponible
Tapa blanda
Condición: Nuevo
EUR 133,37
Descripción del artículo del vendedor
168 pages. 8.66x5.91x0.38 inches. In Stock.
N° de ref. del artículo 3659280496
- Título
- Radiation Beam Collimation Used In Radiotherapy: Radiotherapy
- Autor
- Hegazy, Ehab; Kamal, Moustafa; Dawod, Tamer; Hegazy, Ehab; Kamal, Moustafa; Dawod, Tamer
- Editorial
- Lap Lambert Academic Publishing
- Año de publicación
- 2012
- Estado
- Brand New
- Encuadernación
- Paperback
- Idioma
- inglés
- ISBN 10
- 3659280496
- ISBN 13
- 9783659280498
- Peso del artículo
- 0,3 kilogramos
The objectives of this study are to investigate and compare the dose distribution defined with divergent cerrobend alloy custom blocks to the distribution obtained with multileaf collimator (MLC) provided by high energy linear accelerator. The study was made for simple block replacement situations. Prior to making the comparison, multileaf collimator performance checks will be made. These checks include the following measurements: leaf Attenuation, leaf transmissions, in-between-leaf leakage properties and measurement of tongue and groove effect. By using of ionization chamber in water phantom, percent depth dose, beam flatness, symmetry, penumbra, leaf transmission and leakage will be measured. By using of radiographic films the transmission, penumbra, and verification of leaf position and leaf motion will be determined . Finally output factor of both multileaf collimator and cerrobend block will be measured same field sizes at the same conditions of dosimetry. The final aim of this study to improve the accuracy of cancer treatment delivery
“Sinopsis” puede pertenecer a otra edición de este título.
Reseña del editor
The objectives of this study are to investigate and compare the dose distribution defined with divergent cerrobend alloy custom blocks to the distribution obtained with multileaf collimator (MLC) provided by high energy linear accelerator. The study was made for simple block replacement situations. Prior to making the comparison, multileaf collimator performance checks will be made. These checks include the following measurements: leaf Attenuation, leaf transmissions, in-between-leaf leakage properties and measurement of tongue and groove effect. By using of ionization chamber in water phantom, percent depth dose, beam flatness, symmetry, penumbra, leaf transmission and leakage will be measured. By using of radiographic films the transmission, penumbra, and verification of leaf position and leaf motion will be determined . Finally output factor of both multileaf collimator and cerrobend block will be measured same field sizes at the same conditions of dosimetry. The final aim of this study to improve the accuracy of cancer treatment delivery
“Acerca de” puede pertenecer a otra edición de este título.