Quantitative Magnetic Resonance Imaging
Idioma: inglés
Editorial: Elsevier Science, 2020
Serie: Libro 1 de 1 - Advance in magnetic resonance Technology and Applications
- Tapa blanda
- Nuevo

Librería: moluna, Greven, Alemaniamoluna
Vendedor de AbeBooks desde 9 de julio de 2020
Condición: Nuevo
EUR 216,67
Cantidad disponible: Más de 20 disponibles
Añadir al carritoDescripción del artículo del vendedor
N° de ref. del artículo 352963192
- Título
- Quantitative Magnetic Resonance Imaging
- Editorial
- Elsevier Science
- Año de publicación
- 2020
- Estado
- New
- Encuadernación
- Kartoniert / Broschiert
- Idioma
- inglés
- ISBN 10
- 0128170573
- ISBN 13
- 9780128170571
- Serie
- Libro 1 de 1: Advance in magnetic resonance Technology and Applications
Quantitative Magnetic Resonance Imaging is a 'go-to' reference for methods and applications of quantitative magnetic resonance imaging, with specific sections on Relaxometry, Perfusion, and Diffusion. Each section will start with an explanation of the basic techniques for mapping the tissue property in question, including a description of the challenges that arise when using these basic approaches. For properties which can be measured in multiple ways, each of these basic methods will be described in separate chapters. Following the basics, a chapter in each section presents more advanced and recently proposed techniques for quantitative tissue property mapping, with a concluding chapter on clinical applications.
The reader will learn:
- The basic physics behind tissue property mapping
- How to implement basic pulse sequences for the quantitative measurement of tissue properties
- The strengths and limitations to the basic and more rapid methods for mapping the magnetic relaxation properties T1, T2, and T2*
- The pros and cons for different approaches to mapping perfusion
- The methods of Diffusion-weighted imaging and how this approach can be used to generate diffusion tensor
- maps and more complex representations of diffusion
- How flow, magneto-electric tissue property, fat fraction, exchange, elastography, and temperature mapping are performed
- How fast imaging approaches including parallel imaging, compressed sensing, and Magnetic Resonance
- Fingerprinting can be used to accelerate or improve tissue property mapping schemes
- How tissue property mapping is used clinically in different organs
- Structured to cater for MRI researchers and graduate students with a wide variety of backgrounds
- Explains basic methods for quantitatively measuring tissue properties with MRI - including T1, T2, perfusion, diffusion, fat and iron fraction, elastography, flow, susceptibility - enabling the implementation of pulse sequences to perform measurements
- Shows the limitations of the techniques and explains the challenges to the clinical adoption of these traditional methods, presenting the latest research in rapid quantitative imaging which has the possibility to tackle these challenges
- Each section contains a chapter explaining the basics of novel ideas for quantitative mapping, such as compressed sensing and Magnetic Resonance Fingerprinting-based approaches
“Sinopsis” puede pertenecer a otra edición de este título.
Acerca del autor
Vikas Gulani is the Chair and Fred J. Hodges Professor of Radiology at the University of Michigan. As Chair, his primary goal is to build a compassionate workplace that strives towards excellence. He was previously the Joseph T. Wearn Professor in Radiology, Urology, and Biomedical Engineering and the Director of MRI at Case Western Reserve University and University Hospitals. Dr. Gulani is a physician-scientist interested in MR technology development and clinical translation. His clinical interests include prostate and liver MRI, MR angiography, and in-bore intervention. His scientific interests include relaxometry, diffusion imaging, perfusion, MR microscopy, parallel imaging, rapid acquisitions, and body MRI. His recent work has focused on development and translation of MR Fingerprinting.
Dr. Adrienne Campbell-Washburn is Earl Stadtman Principal Investigator at the MRI Technology Program for the National Heart, Lung, and Blood Institute at the National Institutes of Health. She received her PhD in Medical Physics from University College London.Her research focuses on the development of MRI technology for cardiac, lung and interventional imaging applications. She works on low field MRI technology, advanced MRI acquisitions that leverage non-Cartesian sampling, and reconstruction methods using state-of-the-art computational resources in the clinical environment.
Steven Sourbron holds a Chair in Medical Imaging Physics in the University of Sheffield, UK. He is a theoretical physicist by training, obtained a PhD on perfusion MRI from the Free University of Brussels (Belgium), and performed post-doctoral research in the Ludwig-Maximilian University of Munich (Germany) before taking up a lectureship in the University of Leeds (UK). His research focuses on developing and applying quantitative medical imaging techniques that provide more accurate and more biologically specific assessment of tissue perfusion, function and structure. Much of his current work involves clinical studies on non-invasive assessment of chronic kidney- and liver disease to determine if quantitative MRI can improve prognosis and prediction of treatment effects.
Mariya Doneva is a senior scientist at Philips Research, Hamburg, Germany. She received her BSc and MSc degrees in Physics from the University of Oldenburg in 2006 and 2007, respectively and her PhD degree in Physics from the University of Luebeck in 2010. She was a Research Associate at Electrical Engineering and Computer Sciences department at UC Berkeley between 2015 and 2016. She is a recipient of the Junior Fellow award of the International Society for Magnetic Resonance in Medicine. Her research interests include methods for efficient data acquisition, image reconstruction and quantitative parameter mapping in the context of magnetic resonance imaging.
“Acerca de” puede pertenecer a otra edición de este título.
moluna
Greven, Alemania
Vendedor de AbeBooks desde 9 de julio de 2020
Tarifas de envío de Alemania a Estados Unidos de America
| Artículo | De 26 a 60 días hábiles | De 26 a 60 días hábiles |
|---|---|---|
| Primer artículo | EUR 48,99 | EUR 48,99 |
Métodos de pago
- Cheque
- Giro bancario
- PayPal
Descripción de la tienda
Información empresarial del vendedor
Moluna GmbH
Engberdingdamm 27
Greven, Alemania 48268
Condiciones de venta
Aviso legal
Reconocimiento legal del oferente:
Moluna GmbH
Representadas por el gerente Helge Blischke
Engberdingdamm 27
48268 Greven
Alemania
Teléfono: 02571/5698933
Fax: 02571/5698930
E-Mail: abe@moluna.de
Identificación tributaria del impuesto a las ganancias: DE296281834
inscripto en el Registro Público de Comercio del Tribunal de Primera Instancia Steinfurt
Número HRB de Registro en el Registro Público de Comercio 10553
Somos miembros de la iniciativa « FairCommerce » desde 24.07.2015.
Para más información, consulte: www.haendlerbund.de/faircommerce.
Derecho al desistimiento
Si es un consumidor, puede rescindir el contrato de acuerdo con lo siguiente. Por consumidor se entiende cualquier persona física que actúe con fines ajenos a su actividad comercial, empresarial, oficio o profesión.
Información sobre el derecho de desistimiento
Derecho legal de desistimiento
Tiene derecho a rescindir este contrato en un plazo de 14 días sin dar ningún motivo.
El periodo de desistimiento vencerá a los 14 días desde que usted, o un tercero que no sea el transportista e indicado por usted, adquiera la posesión física del último bien o del último lote o pieza.
Para ejercer el derecho de desistimiento, complete de forma electrónica y envíe una declaración clara en nuestro sitio web, desde "Mis compras" en "Mi cuenta". Le enviaremos sin demora un acuse de recibo de dicho desistimiento a través de un soporte duradero (por ejemplo, por correo electrónico).
Para cumplir con el plazo de desistimiento, basta con que envíe su comunicación relativa al ejercicio del derecho de desistimiento antes de que venza el periodo de desistimiento.
Efectos del desistimiento
Si rescinde este contrato, le reembolsaremos todos los pagos que hayamos recibido de usted, incluidos los gastos de envío (excepto los gastos adicionales que surjan si elige un tipo de envío que no sea el tipo de envío estándar más económico que ofrecemos).
Podemos hacer una deducción del reembolso por la pérdida de valor de cualquier bien suministrado, si la pérdida es el resultado de una manipulación innecesaria por su parte.
Efectuaremos el reembolso sin demoras indebidas y, a más tardar, 14 días después de que se nos informe de su decisión de rescindir este contrato.
Efectuaremos el reembolso utilizando el mismo medio de pago que utilizó para la transacción inicial, a menos que haya acordado expresamente lo contrario; en cualquier caso, no incurrirá en ningún cargo como resultado de dicho reembolso.
Podremos retener el reembolso hasta que hayamos recibido los bienes o hasta que nos haya presentado una prueba de que los ha devuelto, lo que ocurra primero.
Deberá devolver los bienes o entregarlos a moluna, Greven, Germany, sin demoras indebidas y, en cualquier caso, en un plazo máximo de 14 días a partir del día en que nos comunique su desistimiento del presente contrato. El plazo se cumple si devuelve la mercancía antes de que venza el periodo de 14 días. Tendrá que asumir los gastos directos de devolución de los bienes. Usted solo es responsable de la disminución del valor de los bienes como resultado de una manipulación distinta a la necesaria para establecer la naturaleza, las características y el funcionamiento de los bienes.
Excepciones al derecho de desistimiento
El derecho de desistimiento no se aplica a lo siguiente:
- La entrega de periódicos, diarios o revistas, con la excepción de los contratos de suscripción; y
- El suministro de contenido digital que no se proporcione en un soporte tangible (por ejemplo, en un CD o DVD) si, al hacer el pedido, aceptó que podíamos empezar a entregarlo y que no podría desistir una vez iniciada la entrega.