The Modern Inverter Mini-Split Operation And Service Handbook (Paperback)

Idioma: inglés

Editorial: Independently Published, 2026

9798191318783

  • Tapa blanda
  • Nuevo
Ver todos los detalles

Librería: CitiRetail, Stevenage, Reino UnidoCitiRetail

Vendedor de 5 estrellas

Vendedor de IberLibro desde 29 de junio de 2022

Tapa blanda

Condición: Nuevo

EUR 61,41

Envío por EUR 44,13 
Se envía de Reino Unido a Estados Unidos de America

Cantidad disponible: 1 disponible

Añadir al carrito
Devoluciones gratuitas de 30 días

Descripción del artículo del vendedor

Paperback. The ductless inverter mini-split has quietly become one of the most common pieces of comfort equipment a technician will ever touch - and one of the least understood. Most techs can install a line set and pull a vacuum. Far fewer can explain why a suction pressure that would signal a fault on a fixed-speed system is perfectly normal on an inverter running at low speed, or read a pressure-enthalpy diagram well enough to separate a charge problem from an airflow problem before they've burned an afternoon guessing.This handbook closes that gap. Written for the practicing HVAC/R technician and field engineer who already know their way around a manifold gauge set and a multimeter, it builds from the physics up: the vapor-compression cycle and the P-h diagram that makes it a working diagnostic tool, not a classroom abstraction - the power electronics inside the inverter drive itself: rectification, PFC, the IGBT/IPM bridge, PWM, and sensorless PMSM motor control - system components, controls, and inter-unit communication - load calculation, installation, and commissioning - and a full diagnostic arc across error codes, electrical/electronic faults, and refrigerant-side faults.Critically, this edition treats the refrigerant transition every technician now has to navigate. R-410A dominated the field for two decades, but under the AIM Act, new U.S. equipment as of January 2025 must use refrigerants under a 700 GWP threshold - which means R-32 and R-454B, both mildly flammable A2L refrigerants. This book covers R-410A because a vast installed base still runs on it, but builds in the A2L safety practices, charge limits, blend glide, and fractionation rules that older reference titles simply predate.Every chapter closes with fully worked examples and practice problems - in both SI and inch-pound units - with a boxed answer key, so the math of superheat, subcooling, COP, and mass flow becomes something you can actually do at the truck, not just read about.Inside, you'll find: The vapor-compression cycle made quantitative - refrigerating effect, work, COP, and the P-h diagram as a real diagnostic toolRefrigerants, ASHRAE 34 safety classes, and the A2L (R-32/R-454B) transition, including EPA Section 608 and AIM Act complianceInverter drive fundamentals: rectifiers, DC bus, power-factor correction, IGBT/IPM bridges, PWM, and sensorless PMSM controlComponent-by-component coverage of indoor units, outdoor units, controls, sensors, and communication protocolsLoad calculation, sizing, electrical rough-in, and full commissioning/evacuation/charging proceduresPreventive maintenance schedules and a systematic fault-diagnosis methodology across electrical and refrigerant-side faults100+ worked examples and practice problems with full answer keys, in SI and inch-pound units throughoutWhether you're a working technician sharpening your diagnostic method or a field engineer who wants the "why" behind the manufacturer's troubleshooting flowchart, this handbook is built to live on the truck and get used. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability.…

N° de ref. del artículo 9798191318783

Título
The Modern Inverter Mini-Split Operation And Service Handbook (Paperback)
Autor
Stewart McLean
Editorial
Independently Published
Año de publicación
2026
Estado
new
Encuadernación
Paperback
Idioma
inglés
ISBN 13
9798191318783

CitiRetail

Stevenage, Reino Unido

Vendedor de 5 estrellas

Vendedor de IberLibro desde 29 de junio de 2022

Tarifas de envío de Reino Unido a Estados Unidos de America

ArtículoDe 7 a 14 días hábilesDe 7 a 60 días hábiles
Primer artículoEUR 44,13EUR 44,13
Los plazos de entrega los establecen los vendedores y varían según el transportista y la ubicación. Los pedidos que pasan por la aduana pueden sufrir retrasos y los compradores son responsables de los aranceles o tarifas asociadas. Los vendedores pueden ponerse en contacto con usted en relación con cargos adicionales para cubrir cualquier aumento en los costes de envío de los artículos.

Métodos de pago

  • Visa
  • Mastercard
  • American Express
  • Carte Bleue
  • Apple Pay
  • Google Pay

Descripción de la tienda

Online business

Información empresarial del vendedor

ABC BOOKS LIMITED

10 John Street
London, Reino Unido WC1N 2EB