Introduction to Power System Protection (Paperback)

Idioma: inglés

Editorial: Blurb, San Francisco, 2026

9798211894259

  • Tapa blanda
  • Nuevo
Ver todos los detalles

Librería: Grand Eagle Retail, Bensenville, IL, Estados Unidos de AmericaGrand Eagle Retail

Vendedor de 5 estrellas

Vendedor de AbeBooks desde 12 de octubre de 2005

Ver los artículos de este vendedor
Tapa blanda

Condición: Nuevo

EUR 30,90

 Gastos de envío gratis 
Se envía dentro de Estados Unidos de America

Cantidad disponible: 1 disponibles

Añadir al carrito
Devoluciones gratuitas de 30 días

Descripción del artículo del vendedor

Paperback. Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0-5 ampere range for convenience of measurement. The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When I' exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open. System-protection components have the following design criteria: - Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages. - Selectivity: Avoid unnecessary, false trips. - Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise. - Economy: Provide maximum protection at minimum cost. - Simplicity: Minimize protection equipment and circuitry. Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection. The book consists from the following sections: 1. Chapter 1: Power System Faults: 2. Chapter 2: Instrument Transformers. 3. Chapter 3: Overcurrent and Earth Fault Protection Relays. 4. Chapter 4: Radial System Protection. 5. Chapter 5: Zones of Protection. 6. Chapter 6: Differential Relays. 7. Chapter 7: Distance Relays. 8. Chapter 8: Transformer Protection. 9. Chapter 9: Generator Protection. 10. Chapter 10: Busbar Protection. 11. Chapter 11: Circuit Breakers. 12. Chapter 12: Fuses. 13. Chapter 13: References. This item is printed on demand. Shipping may be from multiple locations in the US or from the UK, depending on stock availability.

N° de ref. del artículo 9798211894259

Título
Introduction to Power System Protection (Paperback)
Autor
Dr Hidaia Mahmood Alassouli
Editorial
Blurb, San Francisco
Año de publicación
2026
Estado
new
Encuadernación
Paperback
Idioma
inglés
ISBN 13
9798211894259

Grand Eagle Retail

Bensenville, IL, Estados Unidos de America

Vendedor de 5 estrellas

Vendedor de AbeBooks desde 12 de octubre de 2005

Tarifas de envío en Estados Unidos de America

ArtículoDe 6 a 14 días hábilesDe 6 a 16 días hábiles
Primer artículoEUR 0,00EUR 0,00
Los plazos de entrega los establecen los vendedores y varían según el transportista y la ubicación. Los pedidos que pasan por la aduana pueden sufrir retrasos y los compradores son responsables de los aranceles o tarifas asociadas. Los vendedores pueden ponerse en contacto con usted en relación con cargos adicionales para cubrir cualquier aumento en los costes de envío de los artículos.

Métodos de pago

  • Visa
  • Mastercard
  • American Express
  • Carte Bleue
  • Apple Pay
  • Google Pay

Información empresarial del vendedor

APOLLO ONLINE CORP.

605 Geddes Street
Wilmington, DE Estados Unidos de America 19805