Hvac & R Hands on Troubleshooting
Idioma: inglés
Editorial: Trafford, 2015
- Tapa blanda
- Usado

Librería: Wonder Book, Frederick, MD, Estados Unidos de AmericaWonder Book
Vendedor de AbeBooks desde 1 de noviembre de 1997
Miembro de asociación: ABAAILAB
Ver los artículos de este vendedorCondición: Usado - Aceptable
EUR 22,30
Cantidad disponible: 1 disponibles
Añadir al carritoDescripción del artículo del vendedor
Good condition. A copy that has been read but remains intact. May contain markings such as bookplates, stamps, limited notes and highlighting, or a few light stains.
N° de ref. del artículo P11J-02045
- Título
- Hvac & R Hands on Troubleshooting
- Autor
- Jimenez, Jose C.
- Editorial
- Trafford
- Año de publicación
- 2015
- Estado
- Good
- Encuadernación
- Encuadernación de tapa blanda
- Idioma
- inglés
- ISBN 10
- 1490760997
- ISBN 13
- 9781490760995
“Sinopsis” puede pertenecer a otra edición de este título.
Fragmento. © Reproducción autorizada. Todos los derechos reservados.
HVAC & R Hands on Troubleshooting
By Jose C. JimenezTrafford Publishing
All rights reserved.
Contents
Introduction, xxi,
A Refrigeration Experience, xxv,
How My Interest in Refrigeration Started, xxvii,
01. Refrigerant Leaks (U.S. Coast Guard),
02. Beverage Cooler,
03. Repair of an A/C Equipment,
04. Defected Compressor,
05. A/C Frozen Evaporator,
06. Freezer Grounded,
07. Merchant's Ship,
08. Fish Products Walking Box Repair,
09. Thermostatic Expansion Valve Pilot Type,
10. Frost and Defrost Repeated,
11. Tropicalization?,
12. What's Wrong (DR),
13. Stored Meat Spoiled,
14. Refrigeration System Contamination,
15. Ice Blocks Factory,
16. Restaurant Lower Manhattan: The A/C system Is Not Cooling,
17. Walking Box Storage Oranges,
18. Chemical Reaction,
19. Columbus Avenue Bank: Repair That Wasn't Supposed to Be,
20. Bank: Continuation of a Job?,
21. CBS: A Frozen Evaporator,
22. Rooftop: Cooling Tower's Fan Motor Mounting,
23. Rooftop: Flooding Roof,
24. Computer's Room: Change a Compressor,
25. Museum Restaurant: Helping to Find a Refrigerant Leak,
26. Fashion District: Flooding Cooling Tower,
27. Madison Avenue: No A/C Air Supply After Regular Working Hours,
28. A/C Equipment: Summer Preparation,
29. O/L Wrong Electrical Installation,
30. Carnegie Delicatessen: Compressor Missing Identification,
31. Water Pump Impeller Stuck,
32. Sharing Working Experience,
33. A/C Computer's Room Frozen Evaporator,
34. Care Building A/C Systems Are Not Cooling,
35. Defrost Room Too Cold,
36. Village: A/C System Is Not Cooling,
37. Italian Restaurant: A/C Maintenance Service,
38. Times Square Pharmacy: Preparing the A/C System for Summer,
39. Harvard Club: Refrigerant Recovery,
40. Fish Market: The Crusher Ice/Maker Is Not Working,
41. Italian Restaurant: A/C System Is Not Cooling,
42. Fashion Warehouse: Flooded Cooling Tower,
43. Italian Restaurant: Condensing Unit Replacement,
44. Times Square Pharmacy: A/C System Is Not Cooling,
45. Friars Club: Compressor's Change,
46. Bank 16 St.: Unnecessary Change of Compressor,
47. Italian Restaurant: A/C Not Cooling,
48. Long Island: Service,
49. "Student's Consult" California,
50. Chuck-Full-of-Nuts: Service Call,
51. La Grenouille: Heating Service Call,
52. Empire Restaurant: Thermostat Misalignment,
53. Student: A/C Transaction,
54. Computer's Room: Refrigerant Leak,
55. Mistake: Refrigerant Charge,
56. Computer Room: A/C System Does Not Start,
57. Computer's Room: A/C System Is Not Cooling,
58. WPIX: A/C Not Cooling,
59. WPIX: A/C Repair,
60. Crank Case Broken Sight Glass,
61. Dishonest Behavior,
62. A/C System Not Cooling (Pharmacy),
63. Wiring Electrical Installation,
64. Automobile A/C Repairs,
65. Adding Three Water-Cooled Condensers,
66. Long Time to Start,
67. Exhaust Fan,
68. Settlement Tank,
69. Installation of a Walk-In Freezer,
70. Supermarket Frosted Suction Line,
71. High-Discharge Pressure Operation,
72. Hunt Point Super-Market,
73. Three Compressors Changed,
74. Condensing Unit Location Change,
75. Wrong Diagnostic-Water,
76. Low-Pressure Controls Adjustment,
77. Another Technician,
78. Surplus,
79. Cooling Tower Lines,
80. Compressor's Start but Kicks Out,
81. Low-Pressure Control Adjustment,
82. Fish Tank Refrigeration System,
83. Low-Pressure Control Installation,
84. Semi hermetic Unit Running with a Higher Voltage,
85. Sudden Defrost — Back to Frost,
86. Chiller Coil,
87. Appropriate Use of Electrical Tools,
88. Repair of a 15-Ton A/C System,
89. Testing Commercial Equipment for Leaks,
90. Butchery-Meat Cooler,
91. Refrigerant Leak in a 100-Ton Semi hermetic Compressor,
92. Changing an A/C Semi hermetic Compressor,
93. Water Bill Too High,
94. A/C Equipment Does Not Work,
95. Refrigeration System to Keep Corpses,
96. A/C Installation Check (School),
97. Freezer's Unit Burned Out,
98. Refrigerant Leaking,
99. Solenoid Valve Coil,
100. RSES Seminars,
101. Medium Temperature Walking Box,
102. Water vs. Glycol,
103. A/C Operation,
104. Medium Temperature Cold Cuts Spoiled,
105. Poor Cooling Effect,
106. Ice Maker — Harvesting Problems,
107. Air Conditioning — Poor Cooling,
108. Ice Maker — Operational Problems,
109. Fan Motor Rotation,
110. Installation Care,
111. Instruction,
112. Thought: To Want Is to Be Able,
113. My Affiliation with RSES,
114. Installation Error? (Connecticut),
115. Reunion with Former Student,
116. Supermarket: Flooded Cellar,
117. A/C Problem,
118. Pollution Certificate,
119. Heating Problem,
120. Man from Vegas Course of A/C,
121. Partner — Electric Diagram — System,
122. Water Dripping From Condenser's Pan,
123. Irish Coffee Pub,
124. Excessive Cost of a Hammer,
125. Electrical Problem with the Car,
126. Leaking Refrigerant,
127. Compressor's Parts Leaking,
128. Medium Temperature Frozen Products,
129. Ice Blocks Calculations,
130. Faulty Compressor,
My Railroad Work's Experience - 1, 260,
My Railroad Work's Experience - 2, 265,
My HVAC & R teaching beginnings, 269,
"More than just R and A/C" Experiences, 273,
Other School Teaching Experiences, 275,
Formulae & Other Calculations, 521,
CHAPTER 1
EXPERIENCE 01A
On the last days that I served in the Colombian Navy, I remember some incidents. The one related here was very important to me:
The U.S. Navy sent three Coast Guard vessels to serve in Hawaii. These ships sailed from Mobile, Alabama, and each ship was equipped with a twenty-five-ton air-conditioning system. Two of these systems did not work. The ships were taken to Coco Solo, Panama's shipyard, where they determined that the machines had refrigerant leaks, but these leaks could not be located. Because it was proximate, the vessel's captain communicated with the U.S. naval mission in Barranquilla, Colombia.
They could take the boats back to Mobile, Alabama, or they could take the boats to this city, which was much closer. In the naval mission, Lieutenant Johnson decided to call me to troubleshoot the problem. I remembered my old man always said, "A good soldier neither offers nor refuses." I decided to do my best and prepared some questions for him to ask the captains of both ships. From their response, I had an idea of what the problem was. I explained to him the procedure that could be carried out. Both the captains and Lieutenant Johnson agreed with my plan.
I had taken some training courses in the USA, and was thankful for my education; I saw this as my opportunity to give back something from that knowledge. They took me to the ships to carry out an inspection. As we were down to the lower decks of the ship, I remember bringing some leak-detection tools. I was introduced to both captains and both engine room chiefs, who showed me the two systems that were leaking.
Note. Since the two vessels were of the same type, and used the same R-12, the exact same leak testing procedure was to be performed in both of them.
Before starting any procedure, we also verified the "lead fingers" (four in total) located at the condenser's heads. These pieces of metal are used to minimize the corrosion effect caused on the condenser's metals by the galvanic currents induced by water friction when flowing through the condenser. They were found at about 85% of their efficiency.
* * *
Questions
1. If you were called for a problem similar to this, what would your idea be as to where the refrigerant's leak is?
2. What question should you ask the captain or the engine room chief?
3. What would be the first procedure you should perform?
4. What tools do you need to carry out the procedure?
5. What should the test pressures be?
6. What should be the operating pressures in the system?
EXPERIENCE 02A
This experience was relevant in my life after leaving the Colombian Navy. In this experience, as in other experiences in the future, we should study the complaint or problem, and through the analysis and applying our knowledge, the system should be repaired.
Somebody in the naval base told me that in the cafeteria this particular beverage cooler (property of the Beverages Factory) used to promote its products and lend their customers these commercial refrigeration units, which weren't working well. In those days, the beverage company had a private refrigeration service company to take care of the maintenance and repair of those units.
According to the person in charge, for the last several days the device was not cooling properly. The mechanics they sent all had problems in repairing the unit. He enumerated to me what the mechanics did on the three visits:
1. The first mechanic's visit was due, of course, to a poor cooling of the device. He installed the gauges and "worked" in the equipment for a while. After about fifteen minutes he said the system was OK. And he left.
2. The equipment continued with the same problem. The following day he called the beverage company and another mechanic showed up. This time the mechanic worked a little bit longer and finally said the same as the other mechanic, then left.
3. On the third day, the equipment still failed to work properly. He called the beverage company again. And another mechanic was sent. This one connected the manifold gauges and said that he added some refrigerant and made some adjustments.
This time the cooler worked a little bit better, but it was not enough.
* * *
The system had the following characteristics:
a. It used a 1/3-hp air-cooled hermetically sealed condensing unit, equipped with a packing gland suction service valve attached to the compressor.
b. It used a 1/9-hp condenser fan motor.
c. Low-pressure control. Actual settings = Cut-in. 35 psig; Differential = 25 psig (*)
d. Both motors (working), compressor and condenser fan, used the same electrical characteristics: 115 volts, single phase, 60 Hz.
e. The system used refrigerant 12.
f. It used a capillary tube as a liquid control.
g. Ambient temperature at the equipment location: 80°F.
h. The FLA, discharge, and suction operating pressures, as well as the suction line and the liquid line's temperatures, were a bit too high.
The beverages required a temperature of 40°F.
* * *
Let's see what we can ?nd.
Questions
1. What do you think the problem was?
2. What are supposed to be the operating pressures?
3. What should we do?
EXPERIENCE 03-A
This experience took place sometime later than Experience 02. The lieutenant aggregate of the naval mission was transferred back to the United States. Thus, he had to get rid of some things, among them an 18,000 Btu Carrier air conditioner. He had the bad luck of the equipment failing to work when he gave it to the new owner.
A/C's characteristics:
a. It was a 1 1/2-hp sealed rotary-type compressor.
b. It used a 1/2-hp, three-speed, double-shaft fan motor.
c. Selector switch. Thermostat. Thermal overload.
d. Both motors, compressor and condenser fan, were of the PSC type. Both had the same electrical characteristics: 230 volts, single phase, 60 Hz.
e. Used refrigerant 22.
The lieutenant got in touch with me and told me the problem; he asked me if I could check the device. Thus:
* * *
Questions
1. What do you think the problem was?
2. What test or tests should you carry out to verify this equipment?
3. What should you recommend?
EXPERIENCE 04-A
I continued working with the beverage factory (cited on Experience 02) without any problems. Being aware that I needed some spare replacement parts, I talked to the company's manager and suggested he buy several spare parts, which would be needed for stock instead of ordering one at each time. He did it, and stored them in the factory's warehouse.
On this occasion, I had one problem; when only two compressors were left in the warehouse, the person in charge suggested to me to remove them, and hold them in my shop. I accepted and took them with me. I used one of them immediately and later on (about two months), when I installed the other, and I went to start it, it did not work.
Motor's characteristics: 115 volts, single phase, 60 Hz.
Questions
1. What do you think the problem was?
2. What test or tests should you carry out to verify the problem?
3. What would you recommend?
EXPERIENCE 05A
While working for a "Colombian Technical" Company — —, one of the various works that I remember was in Santa Marta City, on a 10-ton A/C system that had been operating for several years in the Clinic of Social Insurances. According to the person in charge, the equipment had lost little by little its cooling efficiency. For a while now, it's getting to the point where the evaporator, regardless of what they did (*), it was "frozen" all the time.
(*) According to the building's service engineer, in a span of about four years, these are some of the works that they and outside service companies performed on this A/C equipment:
1. Cleaned the evaporator with steam on a monthly basis.
2. Changed air filters on a weekly basis.
3. Changed the fan-blower to increase airflow through the evaporator.
4. Changed the evaporator fan motor (direct drive) with one of a higher speed.
5. Changed the evaporator fan motor type for an indirect drive (belts-pulley-flywheel).
6. Remove the refrigerant from the system and perform a deep vacuum to "clean" the system internally. This last procedure was performed several times.
The system had the following characteristics:
a. A self-contained system with a 10-ton semi hermetic unit, equipped with suction-discharge packing gland service valves type, attached to the compressor.
b. Shell and tube water-cooled-type condenser.
Water from cooling tower, temperature 80°F.
c. Used a 5-hp cooling tower fan motor.
d. Controls: High and low pressure, water-regulating valve. Pump-down (thermostat — liquid line solenoid valve. Thermostat's sensing bulb located at the evaporator's return airflow).
e. The evaporator's fan motor was of 5 hp. All the motors and the compressor, cooling tower, and evaporator fan had the same electrical characteristics 440 volts, three phases, 60 Hz.
f. The system used refrigerant 22.
g. The thermostatic expansion valve was of the external equalizer type.
h. The sight glass in the liquid line was full.
The system's operation was observed and the following were all lower than normal:
1. The suction and discharge pressures.
2. The suction and liquid line temperatures.
3. The running amperage.
4. The condenser's water temperature difference.
After hearing the detailed explanation from the person in charge,
Questions
1. What do you think the problem may be? Keep in mind the system is old and money is not in abundance in this place.
2. What are supposed to be the operating pressures?
3. What are supposed to be the suction and liquid lines temperatures?
4. Why is the running amperage so low?
5. What should be our recommendations?
EXPERIENCE 06-A
At one time, I performed some refrigeration work for a man who was retired from the navy. He had a restaurant called "La Canada" (The Gorge). The work to be performed was in a freezer. This was a self-contained unit, located in the pantry with the refrigeration unit positioned at the end of the cabinet.
The equipment had these characteristics:
1. It was a 1/2-hp air-cooled sealed condensing unit, equipped with a packing gland service valve attached to the compressor's suction side.
2. It used a 1/8-hp shaded pole-type condenser fan motor.
3. Both motors, compressor and condenser fan, used the same electrical characteristics: 115 volts, single phase, 60 Hz.
4. The system used refrigerant 12.
5. The device had a capillary tube as a liquid control.
6. Temperature at the equipment's location was about 85°F.
7. The frozen products to be stored required a temperature of 10°F.
The freezer's compressor, although working, was not cooling, and if touched it "passed current." The equipment was de-energized, the entire electrical installation was reviewed and although the compressor worked, it was "grounded."
After installing the low side gauge, I found that the system did not have any refrigerant.
Questions
1. Up to this point, what do you think the problem was?
2. What tests should we recommend?
3. What do you think can be done?
4. What are supposed to be the operating pressures in this device?
EXPERIENCE 07-A
At this time, I had a call from a Panamanian ship's captain who said that he had heard of me and wanted me to inspect the refrigeration equipment on board his ship. He confided to me that he had gone to Panama's shipyards and the only thing that they had recommended was the purchase of a new compressor. That was a greater problem.
According to the captain, the compressor was of European origin. It was of the open "W" type, with 6 pistons and with a capacity of about 20 tons. Due to the compressor's age and origin, it was not easy to obtain.
Questions
1. What component parts should we recommend to be checked in this device?
2. What do you think can be done?
3. Any other suggestions to the captain?
4. Can we intent the compressor's repair?
EXPERIENCE 08A
One day a retired sergeant major of the Colombian marines whose last name was Arias it came to my shop. He told me that he got some R and A/C works and asked me for help (in some way) to carry them out. He didn't have any mechanical experience.
The first work that he got was in the City of Cartagena, to repair a commercial refrigeration (walk-in box) used to store and freeze seafood products. The owner of this equipment bought the product from the fishermen. He stored it, and later he supplied it to the restaurants throughout the city.
We went to the place and inspected the equipment:
The repair was similar to one that I did on the boat (Experience 07); the only difference was that this equipment was on land.
The characteristics and requirements of the equipment or walk-in storage room were:
1. The compressor was an open "in-line" alternative type with 6 pistons.
2. It had a capacity of 25 tons.
3. The electric motor working at 440 volts, three phases, and 60 Hz. Approximately 550 rpm.
4. The system was working with R-12.
5. Thermostatic (external equalizer) expansion valve.
6. Required storage temperature was -10°F (-23°C)
7. High and low, separated pressure controls.
8. Condenser water-cooled "shell-tube" type (seawater). Water temperature was regularly approximately 80°F.
While inspecting the equipment, we found out (through the owner) that a former student of mine had been there, trying to make the repair. The peculiar thing was, according to the client, he tried to make the repair with the book in hand. In addition, he did not show that much experience, and it made the owner apprehensive as to the type of repair to be done.
After the inspection of the entire system and of all the spare parts, we reached at the conclusion that the work can be performed.
Questions
1. What should be the operating pressures for this system?
2. What tests should we recommend to make sure about the equipment's condition?
3. Should we use some of the information on Experience 07?
EXPERIENCE 09-A
At this time, I met with my brother-in law (he was working for an A/C company), and I asked him what he was doing. He said that he was working with a mechanic in a bank and there, they had some problems. The compressor was repaired. Later, it began to present several compressor faults (rupture of connecting rods, internal valves, and valves' plates, etc.).
Since we were very near the bank, I decided to go there and look at the problem. When we arrived I met with the mechanic. After he answered my greeting, not happily (I didn't have a good relationship with him), I asked him about the problem and he told me that the same problem persisted, the refrigerant returning to the compressor in a liquid state.
He was frank and told me that he didn't understand why.
(Continues...)
Excerpted from HVAC & R Hands on Troubleshooting by Jose C. Jimenez. Copyright © 2015 Jose C. Jimenez. Excerpted by permission of Trafford Publishing.
All rights reserved. No part of this excerpt may be reproduced or reprinted without permission in writing from the publisher.
Excerpts are provided by Dial-A-Book Inc. solely for the personal use of visitors to this web site.
“Acerca de” puede pertenecer a otra edición de este título.
Wonder Book
Frederick, MD, Estados Unidos de America
Vendedor de AbeBooks desde 1 de noviembre de 1997
Tarifas de envío en Estados Unidos de America
| Artículo | De 5 a 9 días hábiles | De 3 a 6 días hábiles |
|---|---|---|
| Primer artículo | EUR 0,00 | EUR 9,65 |
Métodos de pago
Descripción de la tienda
With 3 stores less than 1 hour outside the DC/Metropolitan area (1 in Gaithersburg, 1 in Frederick and 1 in Hagerstown, MD), we have the largest selection of books in the tri-state area. Wonder Book and Video has been in business since 1980 and online since 1997. We have over 1 Million books for sale on our website and another 1 Million books for sale in our 3 locations. Items on Abe are not necessarily in stock at our retail locations. Please do not call the stores to place orders for Abe Books sales. We have a very active online inventory and as such, we can receive multiple orders for the same item. We fill those orders on a first come first serve basis, but will refund promptly any items that are out of stock. Since 1980 it has always been about the books. ALL kinds of books from 95 cent children's paperbacks to five figure rare and collectibles. A merging of the old and new is where we started, and it is where we are today. Our retail stores have always been places where a reader can rush in looking for a title needed for a term paper that is due the next day, or where bibliophiles can get lost "in the stacks" for as long as they wish. In 2002 USAToday recognized us as "1 of 10 Great Old Bookstores", and we have been featured in numerous other newspaper and TV stories including Washington Post and CSpan. Members ABAA, ILAB.…
Miembro de asociación
Los miembros de estas asociaciones se comprometen a mantener los estándares más altos. Garantizan la autenticidad de todos los artículos puestos a la venta. Proporcionan descripciones detalladas y expertas, informan de todos los defectos o restauraciones importantes, incluyen precios claros y precisos y actúan de manera justa y honesta durante la experiencia de compra.Información empresarial del vendedor
Wonder Book
Wonder Book and Video, 1550 Tilco Drive
Frederick, MD Estados Unidos de America 21704
Condiciones de venta
We want you to be satisfied with the book you order. Our general description is
conservative and the book should be as good or better than our general
description
may indicate.
As we often get many requests for the same book, in some cases the book may
already be sold. We will email you regarding the availability.
RETURNS are cheerfully accepted up to 30 days. We ship out within 1-2 business
days and U.S. Standard Shipments usually arrive within 6-9 business days,
Priority 3-6. We want you to be satisfied with the book you order. Our general
description is conservative and the book should be as good or better than our
general description may indicate. We respond to every order inquiry within 2
business days, however our emails may occassionally get moved to spam/junk
folders or refused from your internet/email provider. IF YOU HAVE EMAILED US AND
HAVE NOT RECEIVED A RESPONSE - PLEASE CHECK YOUR SPAM SETTINGS AND/OR ADD OUR
EMAIL TO YOUR ADDRESS BOOK.
Derecho al desistimiento
Si es un consumidor, puede rescindir el contrato de acuerdo con lo siguiente. Por consumidor se entiende cualquier persona física que actúe con fines ajenos a su actividad comercial, empresarial, oficio o profesión.
Información sobre el derecho de desistimiento
Derecho legal de desistimiento
Tiene derecho a rescindir este contrato en un plazo de 14 días sin dar ningún motivo.
El periodo de desistimiento vencerá a los 14 días desde que usted, o un tercero que no sea el transportista e indicado por usted, adquiera la posesión física del último bien o del último lote o pieza.
Para ejercer el derecho de desistimiento, complete de forma electrónica y envíe una declaración clara en nuestro sitio web, desde "Mis compras" en "Mi cuenta". Le enviaremos sin demora un acuse de recibo de dicho desistimiento a través de un soporte duradero (por ejemplo, por correo electrónico).
Para cumplir con el plazo de desistimiento, basta con que envíe su comunicación relativa al ejercicio del derecho de desistimiento antes de que venza el periodo de desistimiento.
Efectos del desistimiento
Si rescinde este contrato, le reembolsaremos todos los pagos que hayamos recibido de usted, incluidos los gastos de envío (excepto los gastos adicionales que surjan si elige un tipo de envío que no sea el tipo de envío estándar más económico que ofrecemos).
Podemos hacer una deducción del reembolso por la pérdida de valor de cualquier bien suministrado, si la pérdida es el resultado de una manipulación innecesaria por su parte.
Efectuaremos el reembolso sin demoras indebidas y, a más tardar, 14 días después de que se nos informe de su decisión de rescindir este contrato.
Efectuaremos el reembolso utilizando el mismo medio de pago que utilizó para la transacción inicial, a menos que haya acordado expresamente lo contrario; en cualquier caso, no incurrirá en ningún cargo como resultado de dicho reembolso.
Podremos retener el reembolso hasta que hayamos recibido los bienes o hasta que nos haya presentado una prueba de que los ha devuelto, lo que ocurra primero.
Deberá devolver los bienes o entregarlos a Wonder Book, Frederick, Maryland, U.S.A., sin demoras indebidas y, en cualquier caso, en un plazo máximo de 14 días a partir del día en que nos comunique su desistimiento del presente contrato. El plazo se cumple si devuelve la mercancía antes de que venza el periodo de 14 días. Tendrá que asumir los gastos directos de devolución de los bienes. Usted solo es responsable de la disminución del valor de los bienes como resultado de una manipulación distinta a la necesaria para establecer la naturaleza, las características y el funcionamiento de los bienes.
Excepciones al derecho de desistimiento
El derecho de desistimiento no se aplica a lo siguiente:
- La entrega de periódicos, diarios o revistas, con la excepción de los contratos de suscripción; y
- El suministro de contenido digital que no se proporcione en un soporte tangible (por ejemplo, en un CD o DVD) si, al hacer el pedido, aceptó que podíamos empezar a entregarlo y que no podría desistir una vez iniciada la entrega.
Condiciones de envío
STANDARD DOMESTIC U.S. SHIPPING IS FREE. Priority Shipping is only $6.99 for first item, $1 each additional. Orders ship within 2 business days. Shipping outside of U.S. is typically between $8-13 and takes between 8-15 business days. Heavier books may require additional shipping. Faster Needs Please Inquire.