- Tapa blanda
- Nuevo

Librería: Grand Eagle Retail, Bensenville, IL, Estados Unidos de AmericaGrand Eagle Retail
Vendedor de IberLibro desde 12 de octubre de 2005
Condición: Nuevo
EUR 63,44
Cantidad disponible: 1 disponible
Añadir al carritoDescripción del artículo del vendedor
Paperback. Four hundred cubic feet per minute per ton. A constant of 1.08 on the air side and 500 on the water side. Every heating, cooling, and refrigeration technician runs on numbers like these - and almost nobody can say where they come from, or when they stop being true.That is because the trade's arithmetic is scattered: a sizing table here, a manufacturer's bulletin there, a slide chart on the back of a pressure-temperature card, a rule of thumb passed down a shop until nobody remembers what it was derived from. It works until the job leaves standard conditions - a duct run at altitude, an air handler in a hundred-and-forty-degree attic, a nameplate that mixes two measurement systems. The technician who has only memorized the number is stuck the moment the table runs out. And a wrong number in this trade is never an abstraction: it is an oversized furnace, a starved coil, a callback, a compressor that dies young.This handbook was built to close that gap. It gathers the calculations a technician actually performs - on a service call, at a start-up, during a replacement estimate - and works each one through from the physical relationship that produces it to the number written on the invoice. Where a shortcut exists, the derivation that justifies it comes first, along with the conditions under which it fails.What you will take from it: One conversion method that handles any unit conversion, including ones you have never seen beforeThe sensible, latent, and total heat equations - and how to correct their constants when conditions are not standardA complete heat loss and heat gain calculation, from design conditions to room-by-room equipment selectionAirflow verified by duct traverse and by temperature rise, the fan laws, and duct sizing by friction loss against available static pressureThe refrigeration cycle read from two gauges and two thermometers - superheat, subcooling, compression ratio, and charge limits for the newer mildly flammable refrigerantsCombustion arithmetic: clocking a meter, input, output, efficiency, temperature rise, and gas pipe sizingPump curves, glycol corrections, and expansion tanks on the water side; amperage, voltage drop, and power factor on the electrical side - through operating cost and simple payback.The apparatus is built for learning and for the truck: 141 fully worked examples showing the equation, the substitution, and the units at every step; more than 400 end-of-chapter practice problems, each answered with a complete worked solution; a master conversion appendix with exact factors; every equation in the book collected in one place; reference data tables; a field quick reference; and a glossary of roughly 190 terms. Chapters are self-contained enough to open anywhere and cross-referenced enough to read straight through. Units follow United States practice, with an appendix for working any calculation in the units used across the English-speaking world.It is written for the apprentice meeting this material for the first time, the trade-school or community-college student with an exam ahead, the working technician tired of trusting numbers he cannot check, and the estimator or service manager who checks them.Stop working from numbers you cannot verify. Get your copy and start carrying the arithmetic that holds up when the table runs out. This item is printed on demand. Shipping may be from multiple locations in the US or from the UK, depending on stock availability.…
N° de ref. del artículo 9798171485887
- Título
- HVAC Math Handbook (Paperback)
- Autor
- Ridgeline Engineering Press
- Editorial
- Independently Published
- Año de publicación
- 2026
- Estado
- new
- Encuadernación
- Paperback
- Idioma
- inglés
- ISBN 13
- 9798171485887
Four hundred cubic feet per minute per ton. A constant of 1.08 on the air side and 500 on the water side. Every heating, cooling, and refrigeration technician runs on numbers like these — and almost nobody can say where they come from, or when they stop being true.
That is because the trade's arithmetic is scattered: a sizing table here, a manufacturer's bulletin there, a slide chart on the back of a pressure-temperature card, a rule of thumb passed down a shop until nobody remembers what it was derived from. It works until the job leaves standard conditions — a duct run at altitude, an air handler in a hundred-and-forty-degree attic, a nameplate that mixes two measurement systems. The technician who has only memorized the number is stuck the moment the table runs out. And a wrong number in this trade is never an abstraction: it is an oversized furnace, a starved coil, a callback, a compressor that dies young.
This handbook was built to close that gap. It gathers the calculations a technician actually performs — on a service call, at a start-up, during a replacement estimate — and works each one through from the physical relationship that produces it to the number written on the invoice. Where a shortcut exists, the derivation that justifies it comes first, along with the conditions under which it fails.
What you will take from it:
- One conversion method that handles any unit conversion, including ones you have never seen before
- The sensible, latent, and total heat equations — and how to correct their constants when conditions are not standard
- A complete heat loss and heat gain calculation, from design conditions to room-by-room equipment selection
- Airflow verified by duct traverse and by temperature rise, the fan laws, and duct sizing by friction loss against available static pressure
- The refrigeration cycle read from two gauges and two thermometers — superheat, subcooling, compression ratio, and charge limits for the newer mildly flammable refrigerants
- Combustion arithmetic: clocking a meter, input, output, efficiency, temperature rise, and gas pipe sizing
- Pump curves, glycol corrections, and expansion tanks on the water side; amperage, voltage drop, and power factor on the electrical side — through operating cost and simple payback.
The apparatus is built for learning and for the truck: 141 fully worked examples showing the equation, the substitution, and the units at every step; more than 400 end-of-chapter practice problems, each answered with a complete worked solution; a master conversion appendix with exact factors; every equation in the book collected in one place; reference data tables; a field quick reference; and a glossary of roughly 190 terms. Chapters are self-contained enough to open anywhere and cross-referenced enough to read straight through. Units follow United States practice, with an appendix for working any calculation in the units used across the English-speaking world.
It is written for the apprentice meeting this material for the first time, the trade-school or community-college student with an exam ahead, the working technician tired of trusting numbers he cannot check, and the estimator or service manager who checks them.
Stop working from numbers you cannot verify. Get your copy and start carrying the arithmetic that holds up when the table runs out.
“Sinopsis” puede pertenecer a otra edición de este título.
Grand Eagle Retail
Bensenville, IL, Estados Unidos de America
Vendedor de IberLibro desde 12 de octubre de 2005
Tarifas de envío en Estados Unidos de America
| Artículo | De 6 a 14 días hábiles | De 6 a 16 días hábiles |
|---|---|---|
| Primer artículo | EUR 0,00 | EUR 0,00 |
Métodos de pago
Información empresarial del vendedor
APOLLO ONLINE CORP.
605 Geddes Street
Wilmington, DE Estados Unidos de America 19805
Condiciones de venta
We guarantee the condition of every book as it¿s described on the Abebooks web sites. If you¿ve changed
your mind about a book that you¿ve ordered, please use the Ask bookseller a question link to contact us
and we¿ll respond within 2 business days.
Books ship from California and Michigan.
Derecho al desistimiento
Si es un consumidor, puede rescindir el contrato de acuerdo con lo siguiente. Por consumidor se entiende cualquier persona física que actúe con fines ajenos a su actividad comercial, empresarial, oficio o profesión.
Información sobre el derecho de desistimiento
Derecho legal de desistimiento
Tiene derecho a rescindir este contrato en un plazo de 14 días sin dar ningún motivo.
El periodo de desistimiento vencerá a los 14 días desde que usted, o un tercero que no sea el transportista e indicado por usted, adquiera la posesión física del último bien o del último lote o pieza.
Para ejercer el derecho de desistimiento, complete de forma electrónica y envíe una declaración clara en nuestro sitio web, desde "Mis compras" en "Mi cuenta". Le enviaremos sin demora un acuse de recibo de dicho desistimiento a través de un soporte duradero (por ejemplo, por correo electrónico).
Para cumplir con el plazo de desistimiento, basta con que envíe su comunicación relativa al ejercicio del derecho de desistimiento antes de que venza el periodo de desistimiento.
Efectos del desistimiento
Si rescinde este contrato, le reembolsaremos todos los pagos que hayamos recibido de usted, incluidos los gastos de envío (excepto los gastos adicionales que surjan si elige un tipo de envío que no sea el tipo de envío estándar más económico que ofrecemos).
Podemos hacer una deducción del reembolso por la pérdida de valor de cualquier bien suministrado, si la pérdida es el resultado de una manipulación innecesaria por su parte.
Efectuaremos el reembolso sin demoras indebidas y, a más tardar, 14 días después de que se nos informe de su decisión de rescindir este contrato.
Efectuaremos el reembolso utilizando el mismo medio de pago que utilizó para la transacción inicial, a menos que haya acordado expresamente lo contrario; en cualquier caso, no incurrirá en ningún cargo como resultado de dicho reembolso.
Podremos retener el reembolso hasta que hayamos recibido los bienes o hasta que nos haya presentado una prueba de que los ha devuelto, lo que ocurra primero.
Deberá devolver los bienes o entregarlos a Grand Eagle Retail, Bensenville, Illinois, U.S.A., sin demoras indebidas y, en cualquier caso, en un plazo máximo de 14 días a partir del día en que nos comunique su desistimiento del presente contrato. El plazo se cumple si devuelve la mercancía antes de que venza el periodo de 14 días. Tendrá que asumir los gastos directos de devolución de los bienes. Usted solo es responsable de la disminución del valor de los bienes como resultado de una manipulación distinta a la necesaria para establecer la naturaleza, las características y el funcionamiento de los bienes.
Excepciones al derecho de desistimiento
El derecho de desistimiento no se aplica a lo siguiente:
- La entrega de periódicos, diarios o revistas, con la excepción de los contratos de suscripción; y
- El suministro de contenido digital que no se proporcione en un soporte tangible (por ejemplo, en un CD o DVD) si, al hacer el pedido, aceptó que podíamos empezar a entregarlo y que no podría desistir una vez iniciada la entrega.
Condiciones de envío
Orders usually ship within 2 business days. All books within the US ship free of charge. Delivery is 4-14 business days anywhere in the United States.
Books ship from California and Michigan.
If your book order is heavy or oversized, we may contact you to let you know extra shipping is required.