Newly regulated toxicants like flame retardants, phthalates, biocides (MIT, CIT, OIT, Triclosan), ortho-phenylphenols, DMFu, and azo dyes lack certified testing methods, making detection in consumer products difficult. To address this, sensitive and rapid analytical techniques were developed for textiles, foam, leather, and plastics. Samples were extracted using an organic solvent at 60°C for 60 min with sonication, followed by centrifugation and filtration. Toxicants were analyzed using GC/MS with a DB-5MS column and helium gas or UFLC. Extraction conditions were optimized, achieving good linearity (r² >= 0.9995) and recovery rates of 100 ± 15%. LOQs ranged from 0.02 - 0.2 mg L⁻¹, with detected levels between 5.18 - 1798.14 mg L⁻¹. These methods effectively identified controlled substances across various matrices.
"Sinopsis" puede pertenecer a otra edición de este libro.
EUR 11,00 gastos de envío desde Alemania a España
Destinos, gastos y plazos de envíoLibrería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Newly regulated toxicants like flame retardants, phthalates, biocides (MIT, CIT, OIT, Triclosan), ortho-phenylphenols, DMFu, and azo dyes lack certified testing methods, making detection in consumer products difficult. To address this, sensitive and rapid analytical techniques were developed for textiles, foam, leather, and plastics. Samples were extracted using an organic solvent at 60°C for 60 min with sonication, followed by centrifugation and filtration. Toxicants were analyzed using GC/MS with a DB-5MS column and helium gas or UFLC. Extraction conditions were optimized, achieving good linearity (r 0.9995) and recovery rates of 100 ± 15%. LOQs ranged from 0.02 - 0.2 mg L , with detected levels between 5.18 - 1798.14 mg L . These methods effectively identified controlled substances across various matrices. 264 pp. Englisch. Nº de ref. del artículo: 9786208433895
Cantidad disponible: 2 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Newly regulated toxicants like flame retardants, phthalates, biocides (MIT, CIT, OIT, Triclosan), ortho-phenylphenols, DMFu, and azo dyes lack certified testing methods, making detection in consumer products difficult. To address this, sensitive and rapid analytical techniques were developed for textiles, foam, leather, and plastics. Samples were extracted using an organic solvent at 60°C for 60 min with sonication, followed by centrifugation and filtration. Toxicants were analyzed using GC/MS with a DB-5MS column and helium gas or UFLC. Extraction conditions were optimized, achieving good linearity (r 0.9995) and recovery rates of 100 ± 15%. LOQs ranged from 0.02 - 0.2 mg L , with detected levels between 5.18 - 1798.14 mg L . These methods effectively identified controlled substances across various matrices. Nº de ref. del artículo: 9786208433895
Cantidad disponible: 2 disponibles
Librería: California Books, Miami, FL, Estados Unidos de America
Condición: New. Nº de ref. del artículo: I-9786208433895
Cantidad disponible: Más de 20 disponibles
Librería: Books Puddle, New York, NY, Estados Unidos de America
Condición: New. Nº de ref. del artículo: 26404397537
Cantidad disponible: 4 disponibles
Librería: Majestic Books, Hounslow, Reino Unido
Condición: New. Print on Demand. Nº de ref. del artículo: 409805374
Cantidad disponible: 4 disponibles
Librería: Biblios, Frankfurt am main, HESSE, Alemania
Condición: New. PRINT ON DEMAND. Nº de ref. del artículo: 18404397547
Cantidad disponible: 4 disponibles