This book presents an arc resistance calculation, measuring tower footing resistance, protection zone setting and application of distance protection relay Siemens 7SA522 with a quadrilateral characteristic approach for protection on a 110kV Duy Xuyen - Thang Binh transmission line in Viet Nam, which using measured data from one terminal line. Afterward, we propose to focus on the building process of MATLAB SIMULINK model for this relay that combines fault detection and classification block, apparent impedance calculation block for all types of faults, and a trip logic block of three protection zone coordination. Further, the proposed relay model is tested by using various fault scenarios (fault types, fault locations, and fault resistance) on the transmission line. It is important to assess what happened, the actual conditions, the causes of mal-operation. Finally, detailed explanation results by MATLAB CODE indicate that the proposed model behavior will help students, technicians, and operators to understand and properly interpret test results and troubleshoot distance function problems when results are not as expected in real-world conditions.
"Sinopsis" puede pertenecer a otra edición de este libro.
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book presents an arc resistance calculation, measuring tower footing resistance, protection zone setting and application of distance protection relay Siemens 7SA522 with a quadrilateral characteristic approach for protection on a 110kV Duy Xuyen - Thang Binh transmission line in Viet Nam, which using measured data from one terminal line. Afterward, we propose to focus on the building process of MATLAB SIMULINK model for this relay that combines fault detection and classification block, apparent impedance calculation block for all types of faults, and a trip logic block of three protection zone coordination. Further, the proposed relay model is tested by using various fault scenarios (fault types, fault locations, and fault resistance) on the transmission line. It is important to assess what happened, the actual conditions, the causes of mal-operation. Finally, detailed explanation results by MATLAB CODE indicate that the proposed model behavior will help students, technicians, and operators to understand and properly interpret test results and troubleshoot distance function problems when results are not as expected in real-world conditions. 56 pp. Englisch. Nº de ref. del artículo: 9786139887101
Cantidad disponible: 2 disponibles
Librería: Revaluation Books, Exeter, Reino Unido
Paperback. Condición: Brand New. 56 pages. 8.66x5.91x0.13 inches. In Stock. Nº de ref. del artículo: zk6139887100
Cantidad disponible: 1 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Vu Phan HuanProf. Le Kim Hung s research interests include power system protection and control at Danang University of Science and Technology (DUT), the University of Danang, Vietnam. Dr. Vu Phan Huan is the position of a team leader. Nº de ref. del artículo: 385875912
Cantidad disponible: Más de 20 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. Neuware -This book presents an arc resistance calculation, measuring tower footing resistance, protection zone setting and application of distance protection relay Siemens 7SA522 with a quadrilateral characteristic approach for protection on a 110kV Duy Xuyen - Thang Binh transmission line in Viet Nam, which using measured data from one terminal line. Afterward, we propose to focus on the building process of MATLAB SIMULINK model for this relay that combines fault detection and classification block, apparent impedance calculation block for all types of faults, and a trip logic block of three protection zone coordination. Further, the proposed relay model is tested by using various fault scenarios (fault types, fault locations, and fault resistance) on the transmission line. It is important to assess what happened, the actual conditions, the causes of mal-operation. Finally, detailed explanation results by MATLAB CODE indicate that the proposed model behavior will help students, technicians, and operators to understand and properly interpret test results and troubleshoot distance function problems when results are not as expected in real-world conditions.Books on Demand GmbH, Überseering 33, 22297 Hamburg 56 pp. Englisch. Nº de ref. del artículo: 9786139887101
Cantidad disponible: 2 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book presents an arc resistance calculation, measuring tower footing resistance, protection zone setting and application of distance protection relay Siemens 7SA522 with a quadrilateral characteristic approach for protection on a 110kV Duy Xuyen - Thang Binh transmission line in Viet Nam, which using measured data from one terminal line. Afterward, we propose to focus on the building process of MATLAB SIMULINK model for this relay that combines fault detection and classification block, apparent impedance calculation block for all types of faults, and a trip logic block of three protection zone coordination. Further, the proposed relay model is tested by using various fault scenarios (fault types, fault locations, and fault resistance) on the transmission line. It is important to assess what happened, the actual conditions, the causes of mal-operation. Finally, detailed explanation results by MATLAB CODE indicate that the proposed model behavior will help students, technicians, and operators to understand and properly interpret test results and troubleshoot distance function problems when results are not as expected in real-world conditions. Nº de ref. del artículo: 9786139887101
Cantidad disponible: 1 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Effect of Fault Resistance on the Operating Behavior of Distance Relay | Phan Huan Vu (u. a.) | Taschenbuch | 56 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN 9786139887101 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. Nº de ref. del artículo: 115422006
Cantidad disponible: 5 disponibles