A simple, accurate, and precise stability-indicating reverse phase high pressure liquid chromatographic method was developed and validated for the estimation of Perindopril arginine, Indapamide, and Amlodipine in the bulk and pharmaceutical dosage form. Chromatographic separation was carried out on ZORBAX RX C8 (250 mm × 4.6 mm, 5 µm) as a stationary phase with a mobile phase of gradient system of Phosphate Buffer with pH 2 containing Decane Sulphonate as ion-pairing agent (A) and Acetonitrile (B) at detection wavelength215 nm with flow rate 1.0 mL/min at column temperature 40 ºC. The tR of Perindopril, Indapamide, and Amlodipine was 31.39 ± 0.21 min, 25.73 ± 0.41min, and 36.95 ± 0.47 min, respectively. The method was linear over the concentration ranges 50-150 µg/ mL for Perindopril, 12.5-37.5 µg/ mL for Indapamide and 50-150 µg/ mL for Amlodipine. The LOD was 0.99 µg/ mL for Perindopril,0.87 µg/ mL for Indapamide and 3.99 µg/ mL for Amlodipine. The LOQ was3.02 µg/ mL for Perindopril, 2.6 µg/ mL for Indapamide and 12.08 µg/ mL for Amlodipine.
"Sinopsis" puede pertenecer a otra edición de este libro.
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A simple, accurate, and precise stability-indicating reverse phase high pressure liquid chromatographic method was developed and validated for the estimation of Perindopril arginine, Indapamide, and Amlodipine in the bulk and pharmaceutical dosage form. Chromatographic separation was carried out on ZORBAX RX C8 (250 mm × 4.6 mm, 5 µm) as a stationary phase with a mobile phase of gradient system of Phosphate Buffer with pH 2 containing Decane Sulphonate as ion-pairing agent (A) and Acetonitrile (B) at detection wavelength215 nm with flow rate 1.0 mL/min at column temperature 40 ºC. The tR of Perindopril, Indapamide, and Amlodipine was 31.39 ± 0.21 min, 25.73 ± 0.41min, and 36.95 ± 0.47 min, respectively. The method was linear over the concentration ranges 50-150 µg/ mL for Perindopril, 12.5-37.5 µg/ mL for Indapamide and 50-150 µg/ mL for Amlodipine. The LOD was 0.99 µg/ mL for Perindopril,0.87 µg/ mL for Indapamide and 3.99 µg/ mL for Amlodipine. The LOQ was3.02 µg/ mL for Perindopril, 2.6 µg/ mL for Indapamide and 12.08 µg/ mL for Amlodipine. 52 pp. Englisch. Nº de ref. del artículo: 9786138968573
Cantidad disponible: 2 disponibles
Librería: Books Puddle, Woodside, NY, Estados Unidos de America
Condición: New. Nº de ref. del artículo: 26397278050
Cantidad disponible: 4 disponibles
Librería: Majestic Books, Hounslow, Reino Unido
Condición: New. Print on Demand. Nº de ref. del artículo: 400180413
Cantidad disponible: 4 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. A simple, accurate, and precise stability-indicating reverse phase high pressure liquid chromatographic method was developed and validated for the estimation of Perindopril arginine, Indapamide, and Amlodipine in the bulk and pharmaceutical dosage form. Chr. Nº de ref. del artículo: 566150458
Cantidad disponible: Más de 20 disponibles
Librería: Biblios, Frankfurt am main, HESSE, Alemania
Condición: New. PRINT ON DEMAND. Nº de ref. del artículo: 18397278056
Cantidad disponible: 4 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A simple, accurate, and precise stability-indicating reverse phase high pressure liquid chromatographic method was developed and validated for the estimation of Perindopril arginine, Indapamide, and Amlodipine in the bulk and pharmaceutical dosage form. Chromatographic separation was carried out on ZORBAX RX C8 (250 mm × 4.6 mm, 5 µm) as a stationary phase with a mobile phase of gradient system of Phosphate Buffer with pH 2 containing Decane Sulphonate as ion-pairing agent (A) and Acetonitrile (B) at detection wavelength215 nm with flow rate 1.0 mL/min at column temperature 40 ºC. The tR of Perindopril, Indapamide, and Amlodipine was 31.39 ± 0.21 min, 25.73 ± 0.41min, and 36.95 ± 0.47 min, respectively. The method was linear over the concentration ranges 50-150 µg/ mL for Perindopril, 12.5-37.5 µg/ mL for Indapamide and 50-150 µg/ mL for Amlodipine. The LOD was 0.99 µg/ mL for Perindopril,0.87 µg/ mL for Indapamide and 3.99 µg/ mL for Amlodipine. The LOQ was3.02 µg/ mL for Perindopril, 2.6 µg/ mL for Indapamide and 12.08 µg/ mL for Amlodipine. Nº de ref. del artículo: 9786138968573
Cantidad disponible: 1 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -A simple, accurate, and precise stability-indicating reverse phase high pressure liquid chromatographic method was developed and validated for the estimation of Perindopril arginine, Indapamide, and Amlodipine in the bulk and pharmaceutical dosage form. Chromatographic separation was carried out on ZORBAX RX C8 (250 mm × 4.6 mm, 5 µm) as a stationary phase with a mobile phase of gradient system of Phosphate Buffer with pH 2 containing Decane Sulphonate as ion-pairing agent (A) and Acetonitrile (B) at detection wavelength215 nm with flow rate 1.0 mL/min at column temperature 40 ºC. The tR of Perindopril, Indapamide, and Amlodipine was 31.39 ± 0.21 min, 25.73 ± 0.41min, and 36.95 ± 0.47 min, respectively. The method was linear over the concentration ranges 50-150 µg/ mL for Perindopril, 12.5-37.5 µg/ mL for Indapamide and 50-150 µg/ mL for Amlodipine. The LOD was 0.99 µg/ mL for Perindopril,0.87 µg/ mL for Indapamide and 3.99 µg/ mL for Amlodipine. The LOQ was3.02 µg/ mL for Perindopril, 2.6 µg/ mL for Indapamide and 12.08 µg/ mL for Amlodipine.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 52 pp. Englisch. Nº de ref. del artículo: 9786138968573
Cantidad disponible: 1 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. ESTIMATION OF PERINDOPRIL ARGININE, INDAPAMIDE AND AMLODIPINE BY HPLC | Bhamini Chaudhary (u. a.) | Taschenbuch | Englisch | 2022 | Scholars' Press | EAN 9786138968573 | Verantwortliche Person für die EU: SIA OmniScriptum Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu. Nº de ref. del artículo: 121284505
Cantidad disponible: 5 disponibles