Heat exchangers are the most common equipment used to transfer heat from high-temperature fluid to low-temperature fluid without direct contact. The present study considers the analytical approach on a concentric tube heat exchanger with the helical baffle. The objective of the study is to reduce the size with effect to increase the effectiveness of the heat exchanger. A heat exchanger with 100mm external diameter and 560mm length contains a helical baffle with 20 – degrees inclination. The designed heat exchanger is analyzed by varying the mass flow rate of hot water from 0.25Kg/s to 2Kg/s at an interval of 0.25kg/s at three different temperatures i.e. 363.16K, 368.16K, 373.16K. A nanofluid is applied to cool the hot water without any loss. The mass flow rate of cold fluid is 2Kg/s at 30 degrees Celsius. The results have displayed that the heat exchanger exhibited appreciable effectiveness at a flow rate of 0.25Kg/s for hot water at 373.16K temperature. Thereby suggesting it as the optimum model of the heat exchanger.
"Sinopsis" puede pertenecer a otra edición de este libro.
Sus derechos de garantía legal: Todos los consumidores de la UE se benefician de al menos dos años de protección de garantía legal para cualquier bien de consumo que se venda en la UE. Ver más
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Heat exchangers are the most common equipment used to transfer heat from high-temperature fluid to low-temperature fluid without direct contact. The present study considers the analytical approach on a concentric tube heat exchanger with the helical baffle. The objective of the study is to reduce the size with effect to increase the effectiveness of the heat exchanger. A heat exchanger with 100mm external diameter and 560mm length contains a helical baffle with 20 - degrees inclination. The designed heat exchanger is analyzed by varying the mass flow rate of hot water from 0.25Kg/s to 2Kg/s at an interval of 0.25kg/s at three different temperatures i.e. 363.16K, 368.16K, 373.16K. A nanofluid is applied to cool the hot water without any loss. The mass flow rate of cold fluid is 2Kg/s at 30 degrees Celsius. The results have displayed that the heat exchanger exhibited appreciable effectiveness at a flow rate of 0.25Kg/s for hot water at 373.16K temperature. Thereby suggesting it as the optimum model of the heat exchanger. 52 pp. Englisch. Nº de ref. del artículo: 9786138955160
Cantidad disponible: 2 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Heat exchangers are the most common equipment used to transfer heat from high-temperature fluid to low-temperature fluid without direct contact. The present study considers the analytical approach on a concentric tube heat exchanger with the helical baffle. The objective of the study is to reduce the size with effect to increase the effectiveness of the heat exchanger. A heat exchanger with 100mm external diameter and 560mm length contains a helical baffle with 20 - degrees inclination. The designed heat exchanger is analyzed by varying the mass flow rate of hot water from 0.25Kg/s to 2Kg/s at an interval of 0.25kg/s at three different temperatures i.e. 363.16K, 368.16K, 373.16K. A nanofluid is applied to cool the hot water without any loss. The mass flow rate of cold fluid is 2Kg/s at 30 degrees Celsius. The results have displayed that the heat exchanger exhibited appreciable effectiveness at a flow rate of 0.25Kg/s for hot water at 373.16K temperature. Thereby suggesting it as the optimum model of the heat exchanger. Nº de ref. del artículo: 9786138955160
Cantidad disponible: 1 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Nº de ref. del artículo: 490309796
Cantidad disponible: Más de 20 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Heat exchangers are the most common equipment used to transfer heat from high-temperature fluid to low-temperature fluid without direct contact. The present study considers the analytical approach on a concentric tube heat exchanger with the helical baffle. The objective of the study is to reduce the size with effect to increase the effectiveness of the heat exchanger. A heat exchanger with 100mm external diameter and 560mm length contains a helical baffle with 20 - degrees inclination. The designed heat exchanger is analyzed by varying the mass flow rate of hot water from 0.25Kg/s to 2Kg/s at an interval of 0.25kg/s at three different temperatures i.e. 363.16K, 368.16K, 373.16K. A nanofluid is applied to cool the hot water without any loss. The mass flow rate of cold fluid is 2Kg/s at 30 degrees Celsius. The results have displayed that the heat exchanger exhibited appreciable effectiveness at a flow rate of 0.25Kg/s for hot water at 373.16K temperature. Thereby suggesting it as the optimum model of the heat exchanger.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 52 pp. Englisch. Nº de ref. del artículo: 9786138955160
Cantidad disponible: 1 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Study on a Concentric Tube Heat Exchanger with Helical Baffle | Experimental Study | Jithendra Sai Raja Chada (u. a.) | Taschenbuch | Englisch | 2021 | Scholars' Press | EAN 9786138955160 | Verantwortliche Person für die EU: Scholars Press, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu. Nº de ref. del artículo: 120366507
Cantidad disponible: 5 disponibles