Artículos relacionados a Study on a Concentric Tube Heat Exchanger with Helical...

Study on a Concentric Tube Heat Exchanger with Helical Baffle: Experimental Study - Tapa blanda

Chada, Jithendra Sai Raja; R., Dharmalingam

 
9786138955160: Study on a Concentric Tube Heat Exchanger with Helical Baffle: Experimental Study

Sinopsis

Heat exchangers are the most common equipment used to transfer heat from high-temperature fluid to low-temperature fluid without direct contact. The present study considers the analytical approach on a concentric tube heat exchanger with the helical baffle. The objective of the study is to reduce the size with effect to increase the effectiveness of the heat exchanger. A heat exchanger with 100mm external diameter and 560mm length contains a helical baffle with 20 – degrees inclination. The designed heat exchanger is analyzed by varying the mass flow rate of hot water from 0.25Kg/s to 2Kg/s at an interval of 0.25kg/s at three different temperatures i.e. 363.16K, 368.16K, 373.16K. A nanofluid is applied to cool the hot water without any loss. The mass flow rate of cold fluid is 2Kg/s at 30 degrees Celsius. The results have displayed that the heat exchanger exhibited appreciable effectiveness at a flow rate of 0.25Kg/s for hot water at 373.16K temperature. Thereby suggesting it as the optimum model of the heat exchanger.

"Sinopsis" puede pertenecer a otra edición de este libro.

Sus derechos de garantía legal: Todos los consumidores de la UE se benefician de al menos dos años de protección de garantía legal para cualquier bien de consumo que se venda en la UE. Ver más