Magnetic Particle Imaging (MPI) is a novel medical imaging technology that is able to acquire the distribution of superparamagnetic iron oxide nanoparticles in real-time with high spatial and temporal resolution. Spatial encoding is realized by a magnetic field configuration generating a field-free point (FFP). Therefore, the FFP is moved through the field of view (FOV). However, at low particle concentrations the signal-to-noise ratio (SNR) decreases and therefore image quality worsens. An enhanced encoding scheme uses instead of the FFP the concept of a field-free line (FFL), whereby a gain of sensitivity of one order of magnitude can be realized. Simulation studies approximate power consumption to a minimum and improve field homogeneity with the result that fast Radon-based reconstruction techniques are feasible. On the basis of these studies, this book describes the manufacturing of an optimized scanner topology realizing an excellent field quality with the help of customized curved rectangular coils. Furthermore, the power loss is efficiently minimized.
"Sinopsis" puede pertenecer a otra edición de este libro.
Dr.-Ing. Matthias Weber studierte Medizinische Ingenieurwissenschaft (MIW) an der Universität zu Lübeck. Nach Aufenthalten an der University of California in Berkeley 2011/12 promovierte er 2017 im Forschungsfeld Magnetic Particle Imaging am Institut für Medizintechnik der Universität zu Lübeck.
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: moluna, Greven, Alemania
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. KlappentextMagnetic Particle Imaging (MPI) is a novel medical imaging technology that is able to acquire the distribution of superparamagnetic iron oxide nanoparticles in real-time with high spatial and temporal resolution. Spatial encod. Nº de ref. del artículo: 449771117
Cantidad disponible: Más de 20 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Magnetic Particle Imaging (MPI) is a novel medical imaging technology that is able to acquire the distribution of superparamagnetic iron oxide nanoparticles in real-time with high spatial and temporal resolution. Spatial encoding is realized by a magnetic field configuration generating a field-free point (FFP). Therefore, the FFP is moved through the field of view (FOV). However, at low particle concentrations the signal-to-noise ratio (SNR) decreases and therefore image quality worsens. An enhanced encoding scheme uses instead of the FFP the concept of a field-free line (FFL), whereby a gain of sensitivity of one order of magnitude can be realized. Simulation studies approximate power consumption to a minimum and improve field homogeneity with the result that fast Radon-based reconstruction techniques are feasible. On the basis of these studies, this book describes the manufacturing of an optimized scanner topology realizing an excellent field quality with the help of customized curved rectangular coils. Furthermore, the power loss is efficiently minimized.Books on Demand GmbH, Überseering 33, 22297 Hamburg 80 pp. Englisch. Nº de ref. del artículo: 9783945954065
Cantidad disponible: 1 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Magnetic Particle Imaging (MPI) is a novel medical imaging technology that is able to acquire the distribution of superparamagnetic iron oxide nanoparticles in real-time with high spatial and temporal resolution. Spatial encoding is realized by a magnetic field configuration generating a field-free point (FFP). Therefore, the FFP is moved through the field of view (FOV). However, at low particle concentrations the signal-to-noise ratio (SNR) decreases and therefore image quality worsens. An enhanced encoding scheme uses instead of the FFP the concept of a field-free line (FFL), whereby a gain of sensitivity of one order of magnitude can be realized. Simulation studies approximate power consumption to a minimum and improve field homogeneity with the result that fast Radon-based reconstruction techniques are feasible. On the basis of these studies, this book describes the manufacturing of an optimized scanner topology realizing an excellent field quality with the help of customized curved rectangular coils. Furthermore, the power loss is efficiently minimized. Nº de ref. del artículo: 9783945954065
Cantidad disponible: 1 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Power-Loss Optimized Field-Free Line Generation for Magnetic Particle Imaging | Matthias Weber | Taschenbuch | 80 S. | Englisch | 2015 | Infinite Science Publishing | EAN 9783945954065 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu Print on Demand. Nº de ref. del artículo: 104241467
Cantidad disponible: 5 disponibles
Librería: Buchpark, Trebbin, Alemania
Condición: Hervorragend. Zustand: Hervorragend | Sprache: Englisch | Produktart: Bücher | Magnetic Particle Imaging (MPI) is a novel medical imaging technology that is able to acquire the distribution of superparamagnetic iron oxide nanoparticles in real-time with high spatial and temporal resolution. Spatial encoding is realized by a magnetic field configuration generating a field-free point (FFP). Therefore, the FFP is moved through the field of view (FOV). However, at low particle concentrations the signal-to-noise ratio (SNR) decreases and therefore image quality worsens. An enhanced encoding scheme uses instead of the FFP the concept of a field-free line (FFL), whereby a gain of sensitivity of one order of magnitude can be realized. Simulation studies approximate power consumption to a minimum and improve field homogeneity with the result that fast Radon-based reconstruction techniques are feasible. On the basis of these studies, this book describes the manufacturing of an optimized scanner topology realizing an excellent field quality with the help of customized curved rectangular coils. Furthermore, the power loss is efficiently minimized. Nº de ref. del artículo: 26142319/1
Cantidad disponible: 1 disponibles