This book deals with the automatic generation control of interconnected thermal systems with Combination of the automatic voltage control and market based deregulated system. In this Particular work thermal unit is considered with two area concept. The primary purpose of the AGC is to balance the total system generation against system load and losses so that the desired Frequency and power interchange with neighboring system are maintained. Any mismatch between generation and demand causes the system frequency to deviate from scheduled value. Thus high frequency deviation may lead to system collapse. Further the role of automatic voltage regulator is to hold terminal voltage magnitude of synchronous generator at a specified level. The interaction between frequency deviation and voltage deviation is analyzed in this book. System performance has been evaluated at various loading disturbances and at the last market structure is considered. Availability of frequency based tariff scheme is employed. Demand can be managed by managing the tariff.
"Sinopsis" puede pertenecer a otra edición de este libro.
Prof. Sachdeva has done B.Tech (Electrical) & M.Tech (Power System). Author has a vast teaching experience at various universities of Punjab.(Punjabi University, Lovely Professional University, Thapar University, Punjab Technical University). His fields of interest are Fuzzy Logic, Power System, ABT, AMR.
Prof. Sachdeva has done B.Tech (Electrical) & M.Tech (Power System). Author has a vast teaching experience at various universities of Punjab.(Punjabi University, Lovely Professional University, Thapar University, Punjab Technical University). His fields of interest are Fuzzy Logic, Power System, ABT, AMR.
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book deals with the automatic generation control of interconnected thermal systems with Combination of the automatic voltage control and market based deregulated system. In this Particular work thermal unit is considered with two area concept. The primary purpose of the AGC is to balance the total system generation against system load and losses so that the desired Frequency and power interchange with neighboring system are maintained. Any mismatch between generation and demand causes the system frequency to deviate from scheduled value. Thus high frequency deviation may lead to system collapse. Further the role of automatic voltage regulator is to hold terminal voltage magnitude of synchronous generator at a specified level. The interaction between frequency deviation and voltage deviation is analyzed in this book. System performance has been evaluated at various loading disturbances and at the last market structure is considered. Availability of frequency based tariff scheme is employed. Demand can be managed by managing the tariff. 104 pp. Englisch. Nº de ref. del artículo: 9783844318074
Cantidad disponible: 2 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Sachdeva GauravProf. Sachdeva has done B.Tech (Electrical) & M.Tech (Power System). Author has a vast teaching experience at various universities of Punjab.(Punjabi University, Lovely Professional University, Thapar University, Punj. Nº de ref. del artículo: 5472260
Cantidad disponible: Más de 20 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book deals with the automatic generation control of interconnected thermal systems with Combination of the automatic voltage control and market based deregulated system. In this Particular work thermal unit is considered with two area concept. The primary purpose of the AGC is to balance the total system generation against system load and losses so that the desired Frequency and power interchange with neighboring system are maintained. Any mismatch between generation and demand causes the system frequency to deviate from scheduled value. Thus high frequency deviation may lead to system collapse. Further the role of automatic voltage regulator is to hold terminal voltage magnitude of synchronous generator at a specified level. The interaction between frequency deviation and voltage deviation is analyzed in this book. System performance has been evaluated at various loading disturbances and at the last market structure is considered. Availability of frequency based tariff scheme is employed. Demand can be managed by managing the tariff.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 104 pp. Englisch. Nº de ref. del artículo: 9783844318074
Cantidad disponible: 1 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book deals with the automatic generation control of interconnected thermal systems with Combination of the automatic voltage control and market based deregulated system. In this Particular work thermal unit is considered with two area concept. The primary purpose of the AGC is to balance the total system generation against system load and losses so that the desired Frequency and power interchange with neighboring system are maintained. Any mismatch between generation and demand causes the system frequency to deviate from scheduled value. Thus high frequency deviation may lead to system collapse. Further the role of automatic voltage regulator is to hold terminal voltage magnitude of synchronous generator at a specified level. The interaction between frequency deviation and voltage deviation is analyzed in this book. System performance has been evaluated at various loading disturbances and at the last market structure is considered. Availability of frequency based tariff scheme is employed. Demand can be managed by managing the tariff. Nº de ref. del artículo: 9783844318074
Cantidad disponible: 1 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Modeling and Automatic Generation Control of Interconnected Thermal Unit | Power System Model Design for Market Based Deregulated System | Gaurav Sachdeva (u. a.) | Taschenbuch | 104 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783844318074 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Nº de ref. del artículo: 107065249
Cantidad disponible: 5 disponibles
Librería: Mispah books, Redhill, SURRE, Reino Unido
Paperback. Condición: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Nº de ref. del artículo: ERICA75838443180706
Cantidad disponible: 1 disponibles