Electrical machines spread over production lines in the industry and can cause the shutdown of whole equipments if they collapse. In the past, safe and reliable operation was basically ensured by manufacturers and users of electrical machines with the help of simple protections such as overcurrent and overvoltage devices. Nowadays, many operators use condition based maintenance strategies in parallel with conventional corrective maintenance so that not only reliability and safety are increased, but also economical losses can be reduced. In the case of induction machines, common faults are asymmetries in the squirrel cage as for example broken bars or fractures in the end rings. This type of fault causes a characteristic harmonic in the different variables of the machine that can be used for the purpose of diagnostics. Although several condition monitoring techniques have been proposed for machines supplied from the mains, the issue is still open in the case of inverter fed variable speed induction machines. In this work, the influence of field oriented control in the fault signature of an induction machine with a single broken rotor bar is investigated. A comparison of different indicators based on the Fourier's Series is presented. Besides, several variants of the field oriented control have been addressed, especially the sensorless schemes. This analysis is validated both through simulations and experimental data obtained in a test bench with a faulty squirrel cage induction machine.
"Sinopsis" puede pertenecer a otra edición de este libro.
Librería: ISD LLC, Bristol, CT, Estados Unidos de America
paperback. Condición: New. Nº de ref. del artículo: 370291
Cantidad disponible: 3 disponibles
Librería: GreatBookPrices, Columbia, MD, Estados Unidos de America
Condición: New. Nº de ref. del artículo: 45914352-n
Cantidad disponible: 3 disponibles
Librería: Grand Eagle Retail, Bensenville, IL, Estados Unidos de America
Paperback. Condición: new. Paperback. Electrical machines spread over production lines in the industry and can cause the shutdown of whole equipments if they collapse. In the past, safe and reliable operation was basically ensured by manufacturers and users of electrical machines with the help of simple protections such as overcurrent and overvoltage devices. Nowadays, many operators use condition based maintenance strategies in parallel with conventional corrective maintenance so that not only reliability and safety are increased, but also economical losses can be reduced. In the case of induction machines, common faults are asymmetries in the squirrel cage as for example broken bars or fractures in the end rings. This type of fault causes a characteristic harmonic in the different variables of the machine that can be used for the purpose of diagnostics. Although several condition monitoring techniques have been proposed for machines supplied from the mains, the issue is still open in the case of inverter fed variable speed induction machines. In this work, the influence of field oriented control in the fault signature of an induction machine with a single broken rotor bar is investigated.A comparison of different indicators based on the Fourier's Series is presented. Besides, several variants of the field oriented control have been addressed, especially the sensorless schemes. This analysis is validated both through simulations and experimental data obtained in a test bench with a faulty squirrel cage induction machine. Shipping may be from multiple locations in the US or from the UK, depending on stock availability. Nº de ref. del artículo: 9783832522537
Cantidad disponible: 1 disponibles
Librería: GreatBookPrices, Columbia, MD, Estados Unidos de America
Condición: As New. Unread book in perfect condition. Nº de ref. del artículo: 45914352
Cantidad disponible: 3 disponibles
Librería: Kennys Bookstore, Olney, MD, Estados Unidos de America
Condición: New. 2009. Paperback. . . . . . Books ship from the US and Ireland. Nº de ref. del artículo: V9783832522537
Cantidad disponible: 2 disponibles
Librería: AussieBookSeller, Truganina, VIC, Australia
Paperback. Condición: new. Paperback. Electrical machines spread over production lines in the industry and can cause the shutdown of whole equipments if they collapse. In the past, safe and reliable operation was basically ensured by manufacturers and users of electrical machines with the help of simple protections such as overcurrent and overvoltage devices. Nowadays, many operators use condition based maintenance strategies in parallel with conventional corrective maintenance so that not only reliability and safety are increased, but also economical losses can be reduced. In the case of induction machines, common faults are asymmetries in the squirrel cage as for example broken bars or fractures in the end rings. This type of fault causes a characteristic harmonic in the different variables of the machine that can be used for the purpose of diagnostics. Although several condition monitoring techniques have been proposed for machines supplied from the mains, the issue is still open in the case of inverter fed variable speed induction machines. In this work, the influence of field oriented control in the fault signature of an induction machine with a single broken rotor bar is investigated.A comparison of different indicators based on the Fourier's Series is presented. Besides, several variants of the field oriented control have been addressed, especially the sensorless schemes. This analysis is validated both through simulations and experimental data obtained in a test bench with a faulty squirrel cage induction machine. Shipping may be from our Sydney, NSW warehouse or from our UK or US warehouse, depending on stock availability. Nº de ref. del artículo: 9783832522537
Cantidad disponible: 1 disponibles
Librería: Kennys Bookshop and Art Galleries Ltd., Galway, GY, Irlanda
Condición: New. 2009. Paperback. . . . . . Nº de ref. del artículo: V9783832522537
Cantidad disponible: 2 disponibles