The main objective of this book was to introduce a new approach to the design of stable digital control systems which is achieved by using a global digital re-design method for converting an analog control system into a digital one is called plant input mapping (PIM).The main advantages of the new approach are the guaranteed closed-loop stability for almost all sampling periods, and the recovery of the continuous-time performance when the sampling period approaches zero. The result guarantees closed loop stability for all non-pathological sampling periods. On the other hand the major disadvantage of this algorithm is depending on plant model. In this thesis, the design some of digital controllers for power system stability which power system represented by single machine infinite bus system (SMIB) Such as Digital power system stabilizer, Digital Proportional-Integral controller, and Digital Proportional-Integral-Derivative controller.
"Sinopsis" puede pertenecer a otra edición de este libro.
The main objective of this book was to introduce a new approach to the design of stable digital control systems which is achieved by using a global digital re-design method for converting an analog control system into a digital one is called plant input mapping (PIM).The main advantages of the new approach are the guaranteed closed-loop stability for almost all sampling periods, and the recovery of the continuous-time performance when the sampling period approaches zero. The result guarantees closed loop stability for all non-pathological sampling periods. On the other hand the major disadvantage of this algorithm is depending on plant model. In this thesis, the design some of digital controllers for power system stability which power system represented by single machine infinite bus system (SMIB) Such as Digital power system stabilizer, Digital Proportional-Integral controller, and Digital Proportional-Integral-Derivative controller.
Gaber Magdy received his B.Sc. and M.Sc. degrees in electrical engineering from Faculty of Energy Engineering, Aswan University, Egypt, in 2011 and 2014, respectively. He joined to the Electrical Engineering Department of Faculty of Energy Engineering, Aswan University, as a Demonstrator in January 2012. Currently, he is an assistant Lecturer.
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The main objective of this book was to introduce a new approach to the design of stable digital control systems which is achieved by using a global digital re-design method for converting an analog control system into a digital one is called plant input mapping (PIM).The main advantages of the new approach are the guaranteed closed-loop stability for almost all sampling periods, and the recovery of the continuous-time performance when the sampling period approaches zero. The result guarantees closed loop stability for all non-pathological sampling periods. On the other hand the major disadvantage of this algorithm is depending on plant model. In this thesis, the design some of digital controllers for power system stability which power system represented by single machine infinite bus system (SMIB) Such as Digital power system stabilizer, Digital Proportional-Integral controller, and Digital Proportional-Integral-Derivative controller. 164 pp. Englisch. Nº de ref. del artículo: 9783659809590
Cantidad disponible: 2 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The main objective of this book was to introduce a new approach to the design of stable digital control systems which is achieved by using a global digital re-design method for converting an analog control system into a digital one is called plant input mapping (PIM).The main advantages of the new approach are the guaranteed closed-loop stability for almost all sampling periods, and the recovery of the continuous-time performance when the sampling period approaches zero. The result guarantees closed loop stability for all non-pathological sampling periods. On the other hand the major disadvantage of this algorithm is depending on plant model. In this thesis, the design some of digital controllers for power system stability which power system represented by single machine infinite bus system (SMIB) Such as Digital power system stabilizer, Digital Proportional-Integral controller, and Digital Proportional-Integral-Derivative controller. Nº de ref. del artículo: 9783659809590
Cantidad disponible: 1 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Magdy GaberGaber Magdy received his B.Sc. and M.Sc. degrees in electrical engineering from Faculty of Energy Engineering, Aswan University, Egypt, in 2011 and 2014, respectively. He joined to the Electrical Engineering Department of . Nº de ref. del artículo: 158605690
Cantidad disponible: Más de 20 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Digital Redesign Of Analog Controllers For Power Systems Using PIM | Gaber Magdy | Taschenbuch | 164 S. | Englisch | 2016 | LAP LAMBERT Academic Publishing | EAN 9783659809590 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Nº de ref. del artículo: 103995823
Cantidad disponible: 5 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The main objective of this book was to introduce a new approach to the design of stable digital control systems which is achieved by using a global digital re-design method for converting an analog control system into a digital one is called plant input mapping (PIM).The main advantages of the new approach are the guaranteed closed-loop stability for almost all sampling periods, and the recovery of the continuous-time performance when the sampling period approaches zero. The result guarantees closed loop stability for all non-pathological sampling periods. On the other hand the major disadvantage of this algorithm is depending on plant model. In this thesis, the design some of digital controllers for power system stability which power system represented by single machine infinite bus system (SMIB) Such as Digital power system stabilizer, Digital Proportional-Integral controller, and Digital Proportional-Integral-Derivative controller.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 164 pp. Englisch. Nº de ref. del artículo: 9783659809590
Cantidad disponible: 1 disponibles
Librería: Mispah books, Redhill, SURRE, Reino Unido
paperback. Condición: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Nº de ref. del artículo: ERICA82936598095946
Cantidad disponible: 1 disponibles