Objectives -Eliminate batteries in flow metering systems -proof that the kinetic energy of the flow is sufficient to power the electronic module of a commercial flowmeter including a wireless transceiver. -Proof that kinetic energy of the flow can be extracted without causing significant resistance to the flow. Conclusion -For air flowing in a 11mm diameter pipe, 18 seconds of energy harvesting at 10 revolution-per-second turbine speed, generated enough power for the flowmeter to operate for 720 seconds at 20 RPS, without backup power -Wireless data transmission was successfully achieved - Flowmeter and generator unit integrated in the same system.
"Sinopsis" puede pertenecer a otra edición de este libro.
Objectives -Eliminate batteries in flow metering systems -proof that the kinetic energy of the flow is sufficient to power the electronic module of a commercial flowmeter including a wireless transceiver. -Proof that kinetic energy of the flow can be extracted without causing significant resistance to the flow. Conclusion -For air flowing in a 11mm diameter pipe, 18 seconds of energy harvesting at 10 revolution-per-second turbine speed, generated enough power for the flowmeter to operate for 720 seconds at 20 RPS, without backup power -Wireless data transmission was successfully achieved - Flowmeter and generator unit integrated in the same system.
Major: Computer ScienceMaster: Mechanical EngineeringPhD: Mechanical Engineering and EnergyLanguages Spanish – English – Chinese (intermediate level)Mechanical Skills CAD/CAM, Machining, Simulating, R&DComputer Skills Signal Processing, Web (ZF1)/Mobile (Android) App, Embedded ATMEGA, STM, EPSON, TIUni.of Mobile, Alabama.Kun Shan Uni. Taiwan
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Objectives -Eliminate batteries in flow metering systems -proof that the kinetic energy of the flow is sufficient to power the electronic module of a commercial flowmeter including a wireless transceiver. -Proof that kinetic energy of the flow can be extracted without causing significant resistance to the flow. Conclusion -For air flowing in a 11mm diameter pipe, 18 seconds of energy harvesting at 10 revolution-per-second turbine speed, generated enough power for the flowmeter to operate for 720 seconds at 20 RPS, without backup power -Wireless data transmission was successfully achieved - Flowmeter and generator unit integrated in the same system. 68 pp. Englisch. Nº de ref. del artículo: 9783659582622
Cantidad disponible: 2 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Objectives -Eliminate batteries in flow metering systems -proof that the kinetic energy of the flow is sufficient to power the electronic module of a commercial flowmeter including a wireless transceiver. -Proof that kinetic energy of the flow can be extracted without causing significant resistance to the flow. Conclusion -For air flowing in a 11mm diameter pipe, 18 seconds of energy harvesting at 10 revolution-per-second turbine speed, generated enough power for the flowmeter to operate for 720 seconds at 20 RPS, without backup power -Wireless data transmission was successfully achieved - Flowmeter and generator unit integrated in the same system. Nº de ref. del artículo: 9783659582622
Cantidad disponible: 1 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Nº de ref. del artículo: 5166440
Cantidad disponible: Más de 20 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Objectives -Eliminate batteries in flow metering systems -proof that the kinetic energy of the flow is sufficient to power the electronic module of a commercial flowmeter including a wireless transceiver. -Proof that kinetic energy of the flow can be extracted without causing significant resistance to the flow. Conclusion -For air flowing in a 11mm diameter pipe, 18 seconds of energy harvesting at 10 revolution-per-second turbine speed, generated enough power for the flowmeter to operate for 720 seconds at 20 RPS, without backup power -Wireless data transmission was successfully achieved - Flowmeter and generator unit integrated in the same system.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 68 pp. Englisch. Nº de ref. del artículo: 9783659582622
Cantidad disponible: 1 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Development of a Digital and Battery-Free Smart Flowmeter | Ronald Garcia | Taschenbuch | 68 S. | Englisch | 2014 | LAP LAMBERT Academic Publishing | EAN 9783659582622 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Nº de ref. del artículo: 105086361
Cantidad disponible: 5 disponibles